Researcher profile

Neelesh A. Patankar

Neelesh A. Patankar contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Pressure -- area loop based phenotypic classification and mechanics of esophagogastric junction physiology

The esophagogastric junction (EGJ) is located at the distal end of the esophagus and acts as a valve allowing swallowed materials to enter the stomach and preventing acid reflux. Irregular weakening or stiffening of the EGJ muscles result in changes to its opening and closing patterns which can progress into esophageal disorders. Therefore, understanding the physics behind the opening and closing cycle of the EGJ provides a mechanistic insight into its function and can help identify the underlying conditions that cause its degradation. Using clinical FLIP data, we plotted the pressure-area hysteresis at the EGJ location and distinguished two major loop types, a pressure dominant loop (PDL) and a tone dominant loop (TDL). In this study, we aimed to identify the key characteristics that define each loop type and find what causes the inversion from one loop to another. To do so, the clinical observations were reproduced using 1D simulations of flow inside a FLIP device located in the esophagus, and the work done by the EGJ wall over time was calculated. This work was decomposed into active and passive components, which revealed the competing mechanisms that dictate the loop type. These mechanisms are esophagus stiffness, fluid viscosity, and the EGJ relaxation pattern. In PDL, the leading source of energy in the cycle is coming from the fluid pressure increase from the peristaltic contraction wave, and in TDL the leading source of energy in the cycle is coming from the contraction and relaxation of the EGJ tone.

preprint2022arXiv

Pulmonary drug delivery and retention: a computational study to identify plausible parameters based on a coupled airway-mucus flow model

Pulmonary drug delivery systems rely on inhalation of drug-laden aerosols produced from aerosol generators such as inhalers, nebulizers etc. On deposition, the drug molecules diffuse in the mucus layer and are also subjected to mucociliary advection which transports the drugs away from the initial deposition site. The availability of the drug at a particular region of the lung is, thus, determined by a balance between these two phenomena. A mathematical analysis of drug deposition and retention in the lungs is developed through a coupled mathematical model of aerosol transport in air as well as drug molecule transport in the mucus layer. The mathematical model is solved computationally to identify suitable conditions for the transport of drug-laden aerosols to the deep lungs. This study identifies the conditions conducive for delivering drugs to the deep lungs which is crucial for achieving systemic drug delivery. The effect of different parameters on drug retention is also characterized for various regions of the lungs, which is important in determining the availability of the inhaled drugs at a target location. Our analysis confirms that drug delivery efficacy remains highest for aerosols in the size range of 1-5 $μ$m. Moreover, it is observed that amount of drugs deposited in the deep lung increases by a factor of 2 when the breathing time period is doubled, with respect to normal breathing, suggesting breath control as a means to increase the efficacy of drug delivery to the deep lung. A higher efficacy also reduces the drug load required to be inhaled to produce the same health effects and hence, can help in minimizing the side effects of a drug.

preprint2021arXiv

Peristaltic regimes in esophageal transport

A FLIP device gives cross-sectional area along the length of the esophagus and one pressure measurement, both as a function of time. Deducing mechanical properties of the esophagus including wall material properties, contraction strength, and wall relaxation from these data is a challenging inverse problem. Knowing mechanical properties can change how clinical decisions are made because of its potential for in-vivo mechanistic insights. To obtain such information, we conducted a parametric study to identify peristaltic regimes by using a 1D model of peristaltic flow through an elastic tube closed on both ends and also applied it to interpret clinical data. The results gave insightful information about the effect of tube stiffness, fluid/bolus density and contraction strength on the resulting esophagus shape through quantitive representations of the peristaltic regimes. Our analysis also revealed the mechanics of the opening of the contraction area as a function of bolus flow resistance. Lastly, we concluded that peristaltic driven flow displays three modes of peristaltic geometries, but all physiologically relevant flows fall into two peristaltic regimes characterized by a tight contraction.

preprint2021arXiv

Pumping Patterns and Work Done during Peristalsis in Finite-length Elastic Tubes

Balloon dilation catheters are often used to quantify the physiological state of peristaltic activity in tubular organs and comment on their ability to propel fluid which is important for healthy human function. To fully understand this system's behavior, we analyzed the effect of a solitary peristaltic wave on a fluid-filled elastic tube with closed ends. A reduced order model that predicts the resulting tube wall deformations, flow velocities and pressure variations is presented. This simplified model is compared with detailed fluid-structure 3D immersed boundary simulations of peristaltic pumping in tube walls made of hyperelastic material. The major dynamics observed in the 3D simulations were also displayed by our 1D model under laminar flow conditions. Using the 1D model, several pumping regimes were investigated and presented in the form of a regime map that summarizes the system's response for a range of physiological conditions. Finally, the amount of work done during a peristaltic event in this configuration was defined and quantified. The variation of elastic energy and work done during pumping was found to have a unique signature for each regime. An extension of the 1D model is applied to enhance patient data collected by the device and find the work done for a typical esophageal peristaltic wave. This detailed characterization of the system's behavior aids in better interpreting the clinical data obtained from dilation catheters. Additionally, the pumping capacity of the esophagus can be quantified for comparative studies between disease groups.

preprint2020arXiv

Tetracycline as an inhibitor to the coronavirus SARS-CoV-2

The coronavirus SARS-CoV-2 remains an extant threat against public health on a global scale. Cell infection begins when the spike protein of SARS-CoV-2 binds with the cell receptor, angiotensin-converting enzyme 2 (ACE2). Here, we address the role of Tetracycline as an inhibitor for the receptor-binding domain (RBD) of the spike protein. Targeted molecular investigation show that Tetracycline binds more favorably to the RBD (-9.40 kcal/mol) compared to Chloroquine (-6.31 kcal/mol) or Doxycycline (-8.08 kcal/mol) and inhibits attachment to ACE2 to a greater degree (binding efficiency of 2.98 $\frac{\text{kcal}}{\text{mol}\cdot \text{nm}^2}$ for Tetracycline-RBD, 5.59 $\frac{\text{kcal}}{\text{mol}\cdot \text{nm}^2}$ for Chloroquine-RBD, 5.16 $\frac{\text{kcal}}{\text{mol}\cdot \text{nm}^2}$ for Doxycycline-RBD). Stronger Tetracycline inhibition is verified with nonequilibrium PMF calculations, for which the Tetracycline-RBD complex exhibits the lowest free energy profile along the dissociation pathway from ACE2. Tetracycline appears to target viral residues that are usually involved in significant hydrogen bonding with ACE2; this inhibition of cellular infection complements the anti-inflammatory and cytokine suppressing capability of Tetracycline, and may further reduce the duration of ICU stays and mechanical ventilation induced by the coronavirus SARS-CoV-2.

preprint2019arXiv

The thermo-wetting instability driving Leidenfrost film collapse

Above a critical temperature known as the Leidenfrost point (LFP), a heated surface can suspend a liquid droplet above a film of its own vapor. The insulating vapor film can be highly detrimental in metallurgical quenching and thermal control of electronic devices, but may also be harnessed to reduce drag and generate power. Manipulation of the LFP has occurred mostly through experiment, giving rise to a variety of semi-empirical models that account for the Rayleigh-Taylor instability, nucleation rates, and superheat limits. However, a truly comprehensive model has been difficult given that the LFP varies dramatically for different fluids and is affected by system pressure, surface roughness and liquid wettability. Here, we identify the vapor film instability for small length scales that ultimately sets the collapse condition at the Leidenfrost point. From a linear stability analysis, it is shown that the main film stabilizing mechanisms are the liquid-vapor surface tension, viscous transport of vapor mass, and evaporation at the liquid-vapor interface. Meanwhile, van der Waals interaction between the bulk liquid and the solid substrate across the vapor phase drives film collapse. This physical insight into vapor film dynamics allows us to derive an ab-initio, mathematical expression for the Leidenfrost point of a fluid. The expression captures the experimental data on the LFP for different fluids under various surface wettabilities and ambient pressures. For fluids that wet the surface (small intrinsic contact angle), the expression can be simplified to a single, dimensionless number that encapsulates the thermo-wetting instability governing the LFP.