Researcher profile

Nathan Saffold

Nathan Saffold contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Hard X-ray emission from the eastern jet of SS 433 powering the W50 `Manatee' nebula: Evidence for particle re-acceleration

We present a broadband X-ray study of W50 (`the Manatee nebula'), the complex region powered by the microquasar SS 433, that provides a test-bed for several important astrophysical processes. The W50 nebula, a Galactic PeVatron candidate, is classified as a supernova remnant but has an unusual double-lobed morphology likely associated with the jets from SS 433. Using NuSTAR, XMM-Newton, and Chandra observations of the inner eastern lobe of W50, we have detected hard non-thermal X-ray emission up to $\sim$30 keV, originating from a few-arcminute size knotty region (`Head') located $\lesssim$ 18$^{\prime}$ (29 pc for a distance of 5.5 kpc) east of SS 433, and constrain its photon index to 1.58$\pm$0.05 (0.5-30 keV band). The index gradually steepens eastward out to the radio `ear' where thermal soft X-ray emission with a temperature $kT$$\sim$0.2 keV dominates. The hard X-ray knots mark the location of acceleration sites within the jet and require an equipartition magnetic field of the order of $\gtrsim$12$μ$G. The unusually hard spectral index from the `Head' region challenges classical particle acceleration processes and points to particle injection and re-acceleration in the sub-relativistic SS 433 jet, as seen in blazars and pulsar wind nebulae.

preprint2022arXiv

The Oscura Experiment

The Oscura experiment will lead the search for low-mass dark matter particles using a very large array of novel silicon Charge Coupled Devices (CCDs) with a threshold of two electrons and with a total exposure of 30 kg-yr. The R&D effort, which began in FY20, is currently entering the design phase with the goal of being ready to start construction in late 2024. Oscura will have unprecedented sensitivity to sub-GeV dark matter particles that interact with electrons, probing dark matter-electron scattering for masses down to 500 keV and dark matter being absorbed by electrons for masses down to 1 eV. The Oscura R&D effort has made some significant progress on the main technical challenges of the experiment, of which the most significant are engaging new foundries for the fabrication of the CCD sensors, developing a cold readout solution, and understanding the experimental backgrounds.

preprint2021arXiv

Passivation of Si(Li) detectors operated above cryogenic temperatures for space-based applications

This work evaluates the viability of polyimide and parylene-C for passivation of lithium-drifted silicon (Si(Li)) detectors. The passivated Si(Li) detectors will form the particle tracker and X-ray detector of the General Antiparticle Spectrometer (GAPS) experiment, a balloon-borne experiment optimized to detect cosmic antideuterons produced in dark matter annihilations or decays. Successful passivation coatings were achieved by thermally curing polyimides, and the optimized coatings form an excellent barrier against humidity and organic contamination. The passivated Si(Li) detectors deliver $\lesssim\,4$ keV energy resolution (FWHM) for 20$-$100 keV X-rays while operating at temperatures of $-$35 to $-45\,^{\circ}$C. This is the first reported successful passivation of Si(Li)-based X-ray detectors operated above cryogenic temperatures.

preprint2019arXiv

Large-area Si(Li) Detectors for X-ray Spectrometry and Particle Tracking for the GAPS Experiment

Large-area lithium-drifted silicon (Si(Li)) detectors, operable 150°C above liquid nitrogen temperature, have been developed for the General Antiparticle Spectrometer (GAPS) balloon mission and will form the first such system to operate in space. These 10 cm-diameter, 2.5 mm-thick multi-strip detectors have been verified in the lab to provide <4 keV FWHM energy resolution for X-rays as well as tracking capability for charged particles, while operating in conditions (~-40°C and ~1 Pa) achievable on a long-duration balloon mission with a large detector payload. These characteristics enable the GAPS silicon tracker system to identify cosmic antinuclei via a novel technique based on exotic atom formation, de-excitation, and annihilation. Production and large-scale calibration of ~1000 detectors has begun for the first GAPS flight, scheduled for late 2021. The detectors developed for GAPS may also have other applications, for example in heavy nuclei identification.