Source author record

Nathal Severijns

Nathal Severijns appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Characterization of a continuous muon source for the Muon-Induced X-ray Emission (MIXE) Technique

The toolbox for material characterization has never been richer than today. Great progress with all kinds of particles and interaction methods provide access to nearly all properties of an object under study. However, a tomographic analysis of the subsurface region remains still a challenge today. In this regard, the Muon-Induced X-ray Emission (MIXE) technique has seen rebirth fueled by the availability of high intensity muon beams. We report here a study conducted at the Paul Scherrer Institute (PSI). It demonstrates that the absence of any beam time-structure leads to low pile-up events and a high signal-to-noise ratio (SNR) with less than one hour acquisition time per sample or data point. This performance creates the perspective to open this technique to a wider audience for the routine investigation of non-destructive and depth-sensitive elemental compositions, for example in rare and precious samples. Using a hetero-structured sample of known elements and thicknesses, we successfully detected the characteristic muonic X-rays, emitted during the capture of a negative muon by an atom, and the gamma-rays resulting from the nuclear capture of the muon, characterizing the capabilities of MIXE at PSI. This sample emphasizes the quality of a continuous beam, and the exceptional SNR at high rates. Such sensitivity will enable totally new statistically intense aspects in the field of MIXE, e.g. elemental 3D-tomography and chemical analysis. Therefore, we are currently advancing our proof-of-concept experiments with the goal of creating a full fledged permanently operated user station to make MIXE available to the wider scientific community as well as industry.

preprint2020arXiv

$Q_{\textrm{EC}}$-value determination for $^{21}$Na$\rightarrow^{21}$Ne and $^{23}$Mg$\rightarrow^{23}$Na mirror-nuclei decays using high-precision mass spectrometry with ISOLTRAP at ISOLDE/CERN

We report on high-precision $Q_{\textrm{EC}}$ values of the $^{21}$Na$\rightarrow^{21}$Ne and $^{23}$Mg$\rightarrow^{23}$Na mirror $β$-transitions from mass measurements with ISOLTRAP at ISOLDE/CERN. A precision of $δm/m = 9 \cdot 10^{-10}$ and $δm/m = 1.5 \cdot 10^{-9}$ was reached for the masses of $^{21}$Na and $^{23}$Mg, respectively. We reduce the uncertainty of the $Q_{\textrm{EC}}$ values by a factor five, making them the most precise experimental input data for the calculation of the corrected $\mathcal{F} t$-value of these mixed Fermi/Gamow-Teller transitions. For the $^{21}$Na$\rightarrow^{21}$Ne $Q_{\textrm{EC}}$ value, a $2.3 σ$ deviation from the literature $Q_{\textrm{EC}}$-value was found.

preprint2019arXiv

First-forbidden transitions in the reactor anomaly

We describe here microscopic calculations performed on the dominant forbidden transitions in reactor antineutrino spectra above 4 MeV using the nuclear shell model. By taking into account Coulomb corrections in the most complete way, we calculate the shape factor with the highest fidelity and show strong deviations from allowed approximations and previously published results. Despite small differences in the ab initio electron cumulative spectra, large differences on the order of several percents are found in the antineutrino spectra. Based on the behaviour of the numerically calculated shape factors we propose a parametrization of forbidden spectra. Using Monte Carlo techniques we derive an estimated spectral correction and uncertainty due to forbidden transitions. We establish the dominance and importance of forbidden transitions in both the reactor anomaly and spectral shoulder analysis. Based on these results, we conclude that a correct treatment of forbidden transitions is indispensable in both the normalization anomaly and spectral shoulder.