Researcher profile

N. Sakamoto

N. Sakamoto contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Development of microwave cavities for measurement of muonium hyperfine structure at J-PARC

The MuSEUM collaboration is planning measurements of the ground-state hyperfine structure (HFS) of muonium at the Japan Proton Accelerator Research Complex (J-PARC), Materials and Life Science Experimental Facility. The high-intensity beam that will soon be available at H-line allows for more precise measurements by one order of magnitude. We plan to conduct two staged measurements. First, we will measure the Mu-HFS in a near-zero magnetic field, and thereafter we will measure it in a strong magnetic field. We have developed two microwave cavities for this purpose. Furthermore, we evaluated systematic uncertainties from such a fluctuation of microwave fields and confirm the requirement of the microwave system, we use a microwave field distribution calculated from the finite element method.

preprint2022arXiv

The design and performance of the XL-Calibur anticoincidence shield

The XL-Calibur balloon-borne hard X-ray polarimetry mission comprises a Compton-scattering polarimeter placed at the focal point of an X-ray mirror. The polarimeter is housed within a BGO anticoincidence shield, which is needed to mitigate the considerable background radiation present at the observation altitude of ~40 km. This paper details the design, construction and testing of the anticoincidence shield, as well as the performance measured during the week-long maiden flight from Esrange Space Centre to the Canadian Northwest Territories in July 2022. The in-flight performance of the shield followed design expectations, with a veto threshold <100 keV and a measured background rate of ~0.5 Hz (20-40 keV). This is compatible with the scientific goals of the mission, where %-level minimum detectable polarisation is sought for a Hz-level source rate.

preprint2013arXiv

Angular distributions of the vector Ay and tensor Ayy, Axx, Axz analyzing powers in the dd->3Hp reaction at 200 MeV

A complete set of analyzing powers for the dd->3Hp reaction at the kinetic beam energy of 200 MeV has been measured in the full angular range in the c.m. frame. The observed signs of the tensor analyzing powers Ayy, Axx, and Axz at forward and backward directions have clearly demonstrated the sensitivity to the ratio of the D- and S-wave components of the triton and deuteron, respectively. The new high-precision data are compared with the prediction of the relativistic multiple-scattering model by using standard wave functions of the three-nucleon bound state and of the deuteron.

preprint2011arXiv

Three Nucleon Force Effects in Intermediate Energy Deuteron Analyzing Powers for dp Elastic Scattering

A complete high precision set of deuteron analyzing powers for elastic deuteron-proton ($dp$) scattering at 250 MeV/nucleon (MeV/N) has been measured. The new data are presented together with data from previous measurements at 70, 100, 135 and 200 MeV/N. They are compared with the results of three-nucleon (3N) Faddeev calculations based on modern nucleon-nucleon (NN) potentials alone or combined with two models of three nucleon forces (3NFs): the Tucson-Melbourne 99 (TM99) and Urbana IX. At 250 MeV/N large discrepancies between pure NN models and data, which are not resolved by including 3NFs, were found at c.m.\ backward angles of $θ_{\rm c.m.}\gtrsim 120^\circ$ for almost all the deuteron analyzing powers. These discrepancies are quite similar to those found for the cross section at the same energy. We found small relativistic effects that cannot resolve the discrepancies with the data indicating that other, short-ranged 3NFs are required to obtain a proper description of the data.

preprint2009arXiv

Cosmic Ray Tests of the Prototype TPC for the ILC Experiment

A time projection chamber (TPC) is a strong candidate for the central tracker of the international linear collider (ILC) experiment and we have been conducting a series of cosmic ray experiments under a magnetic field up to 4 T, using a small prototype TPC with a replaceable readout device: multi-wire proportional chamber (MWPC) or gas electron multiplier (GEM). We first confirmed that the MWPC readout could not be a fall-back option of the ILC-TPC under a strong axial magnetic field of 4 T since its spatial resolution suffered severely from the so called E x B effect in the vicinity of the wire planes. The GEM readout, on the other hand, was found to be virtually free from the E x B effect as had been expected and gave the resolution determined by the transverse diffusion of the drift electrons (diffusion limited). Furthermore, GEMs allow a wider choice of gas mixtures than MWPCs. Among the gases we tried so far a mixture of Ar-CF4-isobutane, in which MWPCs could be prone to discharges, seems promising as the operating gas of the ILC-TPC because of its small diffusion constant especially under a strong magnetic field. We report the measured drift properties of this mixture including the diffusion constant as a function of the electric field and compare them with the predictions of Magboltz. Also presented is the spatial resolution of a GEM-based ILC-TPC estimated from the measurement with the prototype.

preprint2009arXiv

Search for VHE gamma rays from SS433/W50 with the CANGAROO-II telescope

SS433, located at the center of the supernova remnant W50, is a close proximity binary system consisting of a compact star and a normal star. Jets of material are directed outwards from the vicinity of the compact star symmetrically to the east and west. Non-thermal hard X-ray emission is detected from lobes lying on both sides. Shock accelerated electrons are expected to generate sub-TeV gamma rays through the inverse-Compton process in the lobes. Observations of the western X-ray lobe region of SS433/W50 system have been performed to detect sub-TeV gamma-rays using the 10m CANGAROO-II telescope in August and September, 2001, and July and September, 2002. The total observation times are 85.2 hours for ON source, and 80.8 hours for OFF source data. No significant excess of sub-TeV gamma rays has been found at 3 regions of the western X-ray lobe of SS433/W50 system. We have derived 99% confidence level upper limits to the fluxes of gamma rays and have set constraints on the strengths of the magnetic fields assuming the synchrotron/inverse-Compton model for the wide energy range of photon spectrum from radio to TeV. The derived lower limits are 4.3 microgauss for the center of the brightest X-ray emission region and 6.3 microgauss for the far end from SS433 in the western X-ray lobe. In addition, we suggest that the spot-like X-ray emission may provide a major contribution to the hardest X-ray spectrum in the lobe.

preprint2004arXiv

Measurement of the tensor analyzing power T20 in the dd->^3Hen and dd->^3Hp at intermediate energies and at zero degree

The data on the tensor analyzing power T20 in the dd->^3Hen and dd-> ^3Hp reactions at 140, 200 and 270 MeV of the deuteron kinetic energy and at zero degree obtained at RIKEN Accelerator Research Facility are presented. The observed positive sign of T20 clearly demonstrates the sensitivity to the D/S wave ratios in the ^3He and ^3H in the energy domain of the measurements. The T20 data for the ^3He-n and ^3H-p channels are in agreement within experimental accuracy.