Source author record

N. P. Kravchuk

N. P. Kravchuk appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2014arXiv

New results in rare allowed muon and pion decays

Simple dynamics, few available decay channels, and highly controlled radiative and loop corrections, make pion and muon decays a sensitive means of exploring details of the underlying symmetries. We review the current status of the rare decays: pi+ -> e+ nu, pi+ -> e+ nu gamma, pi+ -> pi0 e+ nu, and mu+ -> e+ nu nu-bar gamma. For the latter we report new preliminary values for the branching ratio B(E_gamma >10 MeV, theta_(e-gamma) > 30deg) = 4.365 (9)_stat (42)_syst x 10^{-3}, and the decay parameter eta-bar = 0.006 (17)_stat (18)_syst, both in excellent agreement with standard model predictions. We review recent measurements, particularly by the PIBETA and PEN experiments, and near-term prospects for improvement. These and other similar precise low energy studies complement modern collider results materially.

preprint2013arXiv

The use of segmented cathode of a drift tube for designing a track detector with a high rate capability

Detector rate capability is one of the main parameters for designing a new detector for high energy physics due to permanent rise of the beam luminosity of modern accelerators. One of the widely used detectors for particle track reconstruction is a straw detector based on drift tubes. The rate capability of such detectors is limited by the parameters of readout electronics. The traditional method of increasing detector rate capability is increasing their granularity (a number of readout channels) by reducing the straw diameter and/or by dividing the straw anode wire into two parts (for decreasing the rate per readout channel). A new method of designing straw detectors with a high rate capability is presented and tested. The method is based on dividing the straw cathode into parts and independent readout of each part.

preprint2012arXiv

New studies of allowed pion and muon decays

Building on the rare pion and muon decay results of the PIBETA experiment, the PEN collaboration has undertaken a precise measurement of B_{πe2} = R^π_{e/μ}, the π^+ -> e^+ν(γ) decay branching ratio, at the Paul Scherrer Institute, to reduce the present 40\times experimental precision lag behind theory to ~ 6-7\times. Because of large helicity suppression, R^π_{e/μ} is uniquely sensitive to contributions from non-(V-A) physics, making this decay a particularly suitable subject of study. Even at current precision, the experimental value of B_{πe2} provides the most accurate test of lepton universality available. During runs in 2008-10, PEN has accumulated over 2\times 10^7 π_{e2} events; a comprehensive maximum-likelihood analysis is currently under way. The new data will also lead to improved precision of the earlier PIBETA results on radiative πand μdecays.

preprint2012arXiv

Using the cathode surface of straw tube for measuring the track coordinates along the wire

The coordinate detectors based on straw tubes provide a high accuracy of the radial coordinate measurement using the drift time and a small amount of matter in the way of the measured particles. However, the measurement of the coordinate along the wire constitutes a problem. This paper proposes a method for measuring the hit coordinate along the wire with an accuracy better than 1 mm in a straw tube detector using the signals from the cathodes of the detector.

preprint2011arXiv

Detector with a profile-based cathode and a two-coordinate pad-strip readout system

A detector with a profile-based cathode and a pad-strip cathode readout system is experimentally investigated. Cathode pads arranged along each anode wire are diagonally interconnected and form strips that cross the detector at an angle with respect to the anode wire. Two coordinates from the cathodes and one from the anode wire allow identification of tracks in high multiplicity events with a single detector plane.

preprint2009arXiv

Collins and Sivers asymmetries for pions and kaons in muon-deuteron DIS

The measurements of the Collins and Sivers asymmetries of identified hadrons produced in deep-inelastic scattering of 160 GeV/c muons on a transversely polarised 6LiD target at COMPASS are presented. The results for charged pions and charged and neutral kaons correspond to all data available, which were collected from 2002 to 2004. For all final state particles both the Collins and Sivers asymmetries turn out to be small, compatible with zero within the statistical errors, in line with the previously published results for not identified charged hadrons, and with the expected cancellation between the u- and d-quark contributions.

preprint2009arXiv

PEN experiment: a precise measurement of the pi+ -> e+ nu decay branching fraction

A new measurement of $B_{πe2}$, the $π^+ \to e^+ν(γ)$ decay branching ratio, is currently under way at the Paul Scherrer Institute. The present experimental result on $B_{πe2}$ constitutes the most accurate test of lepton universality available. The accuracy, however, still lags behind the theoretical precision by over an order of magnitude. Because of the large helicity suppression of the $π_{e2}$ decay, its branching ratio is susceptible to significant contributions from new physics, making this decay a particularly suitable subject of study.

preprint2008arXiv

Precise Measurement of pi+ -> e+ nu Branching Ratio

The PEN Collaboration is conducting a new measurement of the pi+ -> e+ nu branching ratio at the Paul Scherrer Institute, with the goal uncertainty of delta B/B(pie2)=5E-4 or lower. At present, the combined accuracy of all published pie2 decay measurements lags behind the theoretical calculation by a factor of 40. In this contribution we report on the PEN detector configuration and its performance during two development runs done in 2007 and 2008.

preprint2003arXiv

Design, Commissioning and Performance of the PIBETA Detector at PSI

We describe the design, construction and performance of the PIBETA detector built for the precise measurement of the branching ratio of pion beta decay, pi+ -> pi0 e+ nu, at the Paul Scherrer Institute. The central part of the detector is a 240-module spherical pure CsI calorimeter covering 3*pi sr solid angle. The calorimeter is supplemented with an active collimator/beam degrader system, an active segmented plastic target, a pair of low-mass cylindrical wire chambers and a 20-element cylindrical plastic scintillator hodoscope. The whole detector system is housed inside a temperature-controlled lead brick enclosure which in turn is lined with cosmic muon plastic veto counters. Commissioning and calibration data were taken during two three-month beam periods in 1999/2000 with pi+ stopping rates between 1.3*E3 pi+/s and 1.3*E6 pi+/s. We examine the timing, energy and angular detector resolution for photons, positrons and protons in the energy range of 5-150 MeV, as well as the response of the detector to cosmic muons. We illustrate the detector signatures for the assorted rare pion and muon decays and their associated backgrounds.