Researcher profile

N. Nicassio

N. Nicassio contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2026arXiv

Beam test studies for a SiPM-based RICH detector prototype for the future ALICE~3 experiment

The ALICE Collaboration is proposing a completely new apparatus, ALICE~3, for the LHC Runs~5 and beyond. In this context, a key subsystem for high-energy charged particle identification will be a proximity-focusing ring-imaging Cherenkov detector using aerogel as radiator and silicon photomultipliers (SiPMs) as photon sensors. We assembled a small-scale prototype instrumented with Hamamatsu S13352 and S13361-3075AE-08 SiPM arrays, readout by custom boards equipped with front-end Petiroc 2A ASICs. The Cherenkov radiator consisted of a 2 cm thick hydrophobic aerogel tile with a refractive index of 1.03 separated from the SiPM plane by a 23 cm expansion gap. The prototype was successfully tested in a campaign at the CERN PS T10 beam line with the goal of validating the design bRICH specifications in terms to achieve the target separation power. We measured a single photon angular resolution of 3.8~mrad at the Cherenkov angle saturation value of 242~mrad, as well as the expected scaling of the angular resolution with the increasing number of detected photons. We also studied the contribution of uncorrelated and correlated background sources with respect to the signal and proved the effectiveness of time matching between charged tracks and photon hits to achieve efficient suppression of the SiPM dark count rate background. In this paper, the detector concept, the description of the tested prototype layout and the main beam test results are reported.

preprint2026arXiv

Development of a novel compact and fast SiPM-based RICH detector for the future ALICE 3 PID system at LHC

A dedicated R\&D is ongoing for the charged particle identification system of the \mbox{ALICE 3} experiment proposed for the LHC Run 5 and beyond. One of the subsystems for the high-energy charged particle identification will be a Ring-Imaging Cherenkov (RICH) detector. The possibility of integrating Cherenkov-based charged particle timing measurements is currently under study. The proposed system is based on a proximity-focusing RICH configuration including an aerogel radiator separated from a SiPM array layer by an expansion gap. A thin high-refractive index window of transparent material, acting as a second Cherenkov radiator, is glued on the SiPM array to enable time-of-flight measurements of charged particles by exploiting the yield of Cherenkov photons in the thin window. We assembled a small-scale prototype instrumented with different Hamamatsu SiPM array sensors with pitches ranging from 1 to 3 mm, readout by custom boards equipped with the front-end Petiroc 2A ASICs to measure charges and times. The primary Cherenkov radiator consisted of a 2 cm thick aerogel tile, while various window materials, including SiO$_2$ and MgF$_2$, were used as secondary Cherenkov radiators. The prototype was successfully tested in a campaign at the CERN PS T10 beam line with pions and protons. This paper summarizes the results achieved in the 2023 test beam campaign.

preprint2026arXiv

Test beam performance of a novel RICH detector with timing capabilities for the future ALICE~3 PID system at LHC

The ALICE Collaboration is proposing a completely new apparatus, ALICE 3, for the LHC Run 5 and beyond. A key subsystem for charged particle identification will be a Ring-Imaging Cherenkov (RICH) detector consisting of an aerogel radiator and a photosensitive surface based on Silicon Photomultiplier (SiPM) arrays in a proximity-focusing configuration. A thin high-refractive index slab of transparent material (window), acting as a second Cherenkov radiator, is glued on the entrance face of the SiPM arrays to achieve precise charged particle timing. Requiring time matching between aerogel Cherenkov photon and track hits leads to an improvement of pattern recognition by discarding the uncorrelated SiPM dark count hits. In this work we present the current status of the R\&D performed for the ALICE 3 RICH detector prototype and the expected full scale system performance. A special focus will be given to the beam test results obtained with a small-scale prototype instrumented with various array of Hamamatsu SiPMs with pitches ranging from 1 to 3 mm. The Cherenkov radiator consisted of a 2 cm thick aerogel tile with a refractive index of 1.03 at 400 nm wavelength. For timing measurements SiPM arrays coupled with two different window materials (SiO$_2$ and MgF$_2$) were used. The prototype was successfully tested in beam test campaigns at the CERN PS T10 beam line. The data were collected with a complete chain of front-end and readout electronics based on the Petiroc 2A and Radioroc 2 together with a picoTDC to measure charges and times. We measured a charged particle detection efficiency above 99\% and a single photon angular resolution better than 4.2 mrad at the Cherenkov angle saturation with a time resolution better than 70 ps for charged particles.

preprint2022arXiv

Measurement of the angular correlation between the two gamma rays emitted in the radioactive decays of a $^{60}$Co source with two NaI(Tl) scintillator

We implemented a didactic experiment to study the angular correlation between the two gamma rays emitted in typical $^{60}$Co radioactive decays. We used two NaI(Tl) scintillators, already available in our laboratory, and a low-activity $^{60}$Co source. The detectors were mounted on two rails, with the source at their center. The first rail was fixed, while the second could be rotated around the source. We performed several measurements by changing the angle between the two scintillators in the range from $90^\circ$ to $180^\circ$. Dedicated background runs were also performed, removing the source from the experimental setup. We found that the signal rate increases with the angular separation between the two scintillators, with small discrepancies from the theoretical expectations.