Source author record

Mohsen Annabestani

Mohsen Annabestani appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2025arXiv

AI-Driven Acoustic Voice Biomarker-Based Hierarchical Classification of Benign Laryngeal Voice Disorders from Sustained Vowels

Benign laryngeal voice disorders affect nearly one in five individuals and often manifest as dysphonia, while also serving as non-invasive indicators of broader physiological dysfunction. We introduce a clinically inspired hierarchical machine learning framework for automated classification of eight benign voice disorders alongside healthy controls, using acoustic features extracted from short, sustained vowel phonations. Experiments utilized 15,132 recordings from 1,261 speakers in the Saarbruecken Voice Database, covering vowels /a/, /i/, and /u/ at neutral, high, low, and gliding pitches. Mirroring clinical triage workflows, the framework operates in three sequential stages: Stage 1 performs binary screening of pathological versus non-pathological voices by integrating convolutional neural network-derived mel-spectrogram features with 21 interpretable acoustic biomarkers; Stage 2 stratifies voices into Healthy, Functional or Psychogenic, and Structural or Inflammatory groups using a cubic support vector machine; Stage 3 achieves fine-grained classification by incorporating probabilistic outputs from prior stages, improving discrimination of structural and inflammatory disorders relative to functional conditions. The proposed system consistently outperformed flat multi-class classifiers and pre-trained self-supervised models, including META HuBERT and Google HeAR, whose generic objectives are not optimized for sustained clinical phonation. By combining deep spectral representations with interpretable acoustic features, the framework enhances transparency and clinical alignment. These results highlight the potential of quantitative voice biomarkers as scalable, non-invasive tools for early screening, diagnostic triage, and longitudinal monitoring of vocal health.

preprint2022arXiv

Warp and Weft Wiring method for rapid, modifiable, self-aligned, and bonding-free fabrication of multi electrodes microfluidic sensors

The need for rapid fabrication of microfluidic devices has become increasingly critical as microfluidics become part of biomedical sensors. Using Warp and Weft Wiring (WWW) of copper wires, this paper presents a novel low-cost method for rapid, self-aligned, bonding-free, and modifiable fabrication of multi-electrodes microfluidic sensors. All the proposed features are promising and highly recommended for the development of Point-of-Care Tests (POCTs), while most of the conventional methods have low chances of coming out of the research labs and play no role in POCTs development. To have an experimental proof of concept, the proposed chip was fabricated and then tested with two sets of experiments that showed the potential applications of water quality management, hygiene, biomedical impedance measurement, cell analysis, flow cytometry, etc.

preprint2019arXiv

Full Analytical 3D Ion Transport Model for Large Deformable IPMC Soft Actuator

Ionic Polymer Metal Composite is a well-known soft electroactive polymer composite that it's promising features tell us that it has adequate potential to be a utilizable and applicative soft actuator in the practical applications, especially in the small size applications. But this smart material is still immature, and one of the reasons that lead to its immaturity is lack of a valid and proper physics-based model for large deformation situations. In practical online and large deformation applications, the inverse non-autoregressive identification based models are the proper choices but if we want to know how IPMC works and what is the physics of its behavior in the large deformation situation the inverse identification based models are deeply blind, and we have to use physical and multi-physical approaches. It is our main aim in this paper, and for the first time, we want to present a fully analytical and physics-based ion transport 3D and non-Linear model for large deformable IPMC. In this direction, based on three dimensional Nernst-Plank PDE we will find a well-defined and valid relationship between input voltage and output tip displacement of IPMC for large deformation situation and with four provable pieces of evidence it will be proven that proposed model has chosen a proper way and it is more complete than previous benchmark and well-known physics-based models for IPMC, and also it is valid and accurate enough for large deformation modeling of IPMC.