Source author record

Miranda Van Stenis

Miranda Van Stenis appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2021arXiv

Microchannel cooling for the LHCb VELO Upgrade I

The LHCb VELO Upgrade I, currently being installed for the 2022 start of LHC Run 3, uses silicon microchannel coolers with internally circulating bi-phase \cotwo for thermal control of hybrid pixel modules operating in vacuum. This is the largest scale application of this technology to date. Production of the microchannel coolers was completed in July 2019 and the assembly into cooling structures was completed in September 2021. This paper describes the R\&D path supporting the microchannel production and assembly and the motivation for the design choices. The microchannel coolers have excellent thermal peformance, low and uniform mass, no thermal expansion mismatch with the ASICs and are radiation hard. The fluidic and thermal performance is presented.

preprint2020arXiv

Timing Performance of a Micro-Channel-Plate Photomultiplier Tube

The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r$<$5.5\,mm) the time resolution of the two MCP-PMTs combined is better than 10~ps. The signal amplitude decreases in the outer region due to less light reaching the photocathode, resulting in a worse time resolution. The observed radial dependence is in quantitative agreement with a dedicated simulation. With this characterization, the suitability of MCP-PMTs as $\text{t}_\text{0}$ reference detectors has been validated.

preprint2010arXiv

First results of spherical GEMs

We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical GEMs are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed. This eliminates the parallax error for detection of x-rays, neutrons or UV photons when a gaseous converter is used. This parallax error limits the spatial resolution at wide scattering angles. Besides spherical GEMs, we have developed curved spacers to maintain accurate spacing, and a conical field cage to prevent edge distortion of the radial drift field up to the limit of the angular acceptance of the detector. With these components first tests are done in a setup with a spherical entrance window but a planar readout structure; results will be presented and discussed. A flat readout structure poses difficulties, however. Therefore we will show advanced plans to make a prototype of an entirely spherical double-GEM detector, including a spherical 2D readout structure. This detector will have a superior position resolution, also at wide angles, and a high rate capability.

preprint2010arXiv

Progress on large area GEMs (VCI 2010)

The Gas Electron Multiplier (GEM) manufacturing technique has recently evolved to allow the production of large area GEMs. A novel approach based on single mask photolithography eliminates the mask alignment issue, which limits the dimensions in the traditional double mask process. Moreover, a splicing technique overcomes the limited width of the raw material. Stretching and handling issues in large area GEMs have also been addressed. Using the new improvements it was possible to build a prototype triple-GEM detector of ~ 2000 cm2 active area, aimed at an application for the TOTEM T1 upgrade. Further refinements of the single mask technique give great control over the shape of the GEM holes and the size of the rims, which can be tuned as needed. In this framework, simulation studies can help to understand the GEM behavior depending on the hole shape.

preprint2009arXiv

Spherical GEMs for parallax-free detectors

We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical \textsc{gem}s are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed. This would eliminate the parallax error for detection of x-rays, neutrons or UV photons when a gaseous converter is used. This parallax error limits the spatial resolution at wide scattering angles. The method is inexpensive and flexible towards possible changes in the design. We show advanced plans to make a prototype of an entirely spherical triple-GEM detector, including a spherical readout structure. This detector will have a superior position resolution, also at wide angles, and a high rate capability. A completely spherical gaseous detector has never been made before.