Researcher profile

Mikko Kiviranta

Mikko Kiviranta contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - Emerging
6works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2016arXiv

Development of frequency domain multiplexing for the X-ray Integral Field Unit (X-IFU) on the Athena

We are developing the frequency domain multiplexing (FDM) read-out of transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field Unit (X-IFU) instrument on board of the future European X-Ray observatory Athena. The X-IFU instrument consists of an array of $\sim$3840 TESs with a high quantum efficiency ($>$90 \%) and spectral resolution $ΔE$=2.5 eV $@$ 7 keV ($E/ΔE\sim$2800). FDM is currently the baseline readout system for the X-IFU instrument. Using high quality factor LC filters and room temperature electronics developed at SRON and low-noise two stage SQUID amplifiers provided by VTT, we have recently demonstrated good performance with the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. An integrated noise equivalent power resolution of about 2.0 eV at 1.7 MHz has been demonstrated with a pixel from a new TES array from NASA/Goddard (GSFC-A2). We have achieved X-ray energy resolutions $\sim$2.5 eV at AC bias frequency at 1.7 MHz in the single pixel read-out. We have also demonstrated for the first time an X-ray energy resolution around 3.0 eV in a 6 pixel FDM read-out with TES array (GSFC-A1). In this paper we report on the single pixel performance of these microcalorimeters under MHz AC bias, and further results of the performance of these pixels under FDM.

preprint2016arXiv

Development of TES-based detectors array for the X-ray Integral Field Unit (X-IFU) on the future x-ray observatory ATHENA

We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250μm squared, AuBi absorbers. We designed and fabricated devices with different contact geometries between the absorber and the TES to optimise the detector performance and with different wiring topology to mitigate the self-magnetic field. The design is tailored to optimise the performance under Frequency Domain Multiplexing. In this paper we review the main design feature of the pixels array and we report on the performance of the 18 channels, 2-5MHz frequency domain multiplexer that will be used to characterised the detector array.

preprint2016arXiv

Development of the superconducting detectors and read-out for the X-IFU instrument on board of the X-ray observatory Athena

The Advanced Telescope for High-Energy Astrophysics (Athena) has been selected by ESA as its second large-class mission. The future European X-ray observatory will study the hot and energetic Universe with its launch foreseen in 2028. Microcalorimeters based on superconducting Transition-edge sensor (TES) are the chosen technology for the detectors array of the X-ray Integral Field Unit (X-IFU) on board of Athena. The X-IFU is a 2-D imaging integral-field spectrometer operating in the soft X-ray band (0.3 -12 keV). The detector consists of an array of 3840 TESs coupled to X-ray absorbers and read out in the MHz bandwidth using Frequency Domain Multiplexing (FDM) based on Superconducting QUantum Interference Devices (SQUIDs). The proposed design calls for devices with a high filling-factor, high quantum efficiency, relatively high count-rate capability and an energy resolution of 2.5 eV at 5.9 keV. The paper will review the basic principle and the physics of the TES-based microcalorimeters and present the state-of-the art of the FDM read-out.

preprint2015arXiv

Multiplexed readout demonstration of a TES-based detector array in a resistance locked loop

TES-based bolometer and microcalorimeter arrays with thousands of pixels are under development for several space-based and ground-based applications. A linear detector response and low levels of cross talk facilitate the calibration of the instruments. In an effort to improve the properties of TES-based detectors, fixing the TES resistance in a resistance-locked loop (RLL) under optical loading has recently been proposed. Earlier theoretical work on this mode of operation has shown that the detector speed, linearity and dynamic range should improve with respect to voltage biased operation. This paper presents an experimental demonstration of multiplexed readout in this mode of operation in a TES-based detector array with noise equivalent power values (NEP) of $3.5\cdot 10^{-19} $W/$\sqrt{\mathrm{Hz}}$. The measured noise and dynamic properties of the detector in the RLL will be compared with the earlier modelling work. Furthermore, the practical implementation routes for future FDM systems for the readout of bolometer and microcalorimeter arrays will be discussed.

preprint2012arXiv

Operation of transition edge sensors in a resistance locked loop

We propose to operate a superconducting transition edge sensor (TES) using a different type of biasing, in which the resistance of the TES is kept constant by means of feedback on the bias voltage and is independent of the incoming signal power. By combining a large negative electrothermal feedback with a load independent resistance, this approach can significantly linearise the response of the detector in the large signal limit. The electrothermal feedback is enhanced in comparison with the commonly applied voltage biasing, which further increases the speed of the detector. Furthermore, in frequency domain multiplexed (FDM) readout, the sinusoidal bias voltages for each TES can be generated cryogenically with the readout SQUIDs.