Source author record

Michel van Ruymbeke

Michel van Ruymbeke appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2014arXiv

Hydrological and tectonic strain forces measured from a karstic cave using extensometers

In order to monitor the hydrological strain forces of the karst micro fissure networks and local fault activities, six capacitive extensometers were installed inside a karstic cave near the midi-fault in Belgium. From 2004 to 2008, the nearby Lomme River experienced several heavy rains, leading to flooding inside the Rochefort cave. The highest water level rose more than thirteen meters, the karstic fissure networks were filled with water, which altered the pore pressure of the cave. The strain response to the hydrological induced pore pressure changes are separately deduced from fifteen events when the water level exceeded six meters. The strain measured from the extensometer show a linear contraction during the water recharge and a nonlinear exponential extension releasing during the water discharge. The sensitivity and stability of the sensor are constrained by comparing continuously observed tidal strain waves with a theoretical model. Finally, a local fault deformation rate around $0.03 \pm 0.002$mm/yr is estimated from more than four years' records.

preprint2014arXiv

Royal Observatory of Belgium Gravitational balance

An astatized symmetrical vertical pendulum is monitoring torque Γ(M) resulting of gravitational attractions exerted by two external masses M moving up down. Local gravity field g produce the main pendulum restoring torque combined with a very weak variable torque Γ(c) induced by rotation of watch needles fixed to the pendulum. Transfer of fundamental units to calibrate the Γ(c) torques is obtained by a reference torque Γ(μ) resulting of precise displacements of a well known mass μ. We permanently monitored ratio between the gravitational effect Γ(M) and calibrated Γ(c) to determine G. Position of the pendulum is measured with a capacitive bridge. Bias voltages sent to two electrodes set-up at the bottom of the pendulum allows to feedback pendulum with a controlled electrostatic torque. We discuss potential interest of our prototype to design a multi pendulum system to check systematic effects for different geometries and various kinds of materials.

preprint2014arXiv

Spring gravimeter calibration experiment with an inertial acceleration platform

This experiment tested an automatically calibrate the relatively gravimeter with an absolute inertial force. The whole calibration system was controlled by microprocessor and low frequency oscillations were generated by a step motor. It could produce different period low frequency sinusoid inertial force. A LVDT (Linear Variable Differential Transformer) sensor was introduced to determine the frequency transfer function and the stability of platform vertical motion. The error of vertical displacement induced by the mechanical part of platform is less than 0.01 mm. Two LCR gravimeters (G336, G906) were settled on the platform. G336 was in the centre of platform and G906 was in the left side. A calibration program has been integrated in the micro processor which could send calibrate signal once a week. During the more than 7 moths experiment, the scale factor of G336 is 8128.647 nm/s2/v with 1.1% uncertainties and G906 is 9421.017 nm/s2/v with 2.7% fluctuations.