Source author record

Merlin Kole

Merlin Kole appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2022arXiv

Adding Gamma-ray Polarimetry to the Multi-Messenger Era

The last decade has seen the emergence of two new fields within astrophysics: gamma ray polarimetry and GW astronomy. The former, which aims to measure the polarization of gamma rays in the energy range of 10s to 100s of keV, from astrophysical sources, saw the launch of the first dedicated polarimeters such as GAP and POLAR. On the other hand, GW astronomy started with the detection of the first black hole mergers by LIGO in 2015, followed by the first multi messenger detection in 2017. While the potential of the two individual fields has been discussed in detail in the literature, the potential for joint observations has thus far been ignored. In this article, we aim to define how GW observations can best contribute to gamma ray polarimetry and study the scientific potential of joint analyses. In addition we aim to provide predictions on feasibility of such joint measurements in the near future. We study which GW observables can be combined with measurements from gamma ray polarimetry to improve the discriminating power regarding GRB emission models. We then provide forecasts for the joint detection capabilities of current and future GW detectors and polarimeters. Our results show that by adding GW data to polarimetry, a single precise joint detection would allow to rule out the majority of emission models. We show that in the coming years joint detections between GW and gamma ray polarimeters might already be possible. Although these would allow to constrain part of the model space, the probability of highly constraining joint detections will remain small in the near future. However, the scientific merit held by even a single such measurement makes it important to pursue such an endeavour. Furthermore, we show that using the next generation of GW detectors, such as the Einstein Telescope, joint detections for which GW data can better complement the polarization data become possible.

preprint2022arXiv

Gamma-Ray Polarimetry of the Crab Pulsar Observed by POLAR

The X/$γ$ ray polarimetry of the Crab pulsar/nebula is believed to hold crucial information on their emission models. In the past, several missions have shown evidence of polarized emission from the Crab. The significance of these measurements remains however limited. New measurements are therefore required. POLAR is a wide Field of View Compton-scattering polarimeter (sensitive in 50-500 keV) onboard the Chinese spacelab Tiangong-2 which took data from September 2016 to April 2017. Although not designed to perform polarization measurements of pulsars, we present here a novel method which can be applied to POLAR as well as that of other wide Field of View polarimeters. The novel polarimetric joint-fitting method for the Crab pulsar observations with POLAR, allows us to obtain constraining measurements of the pulsar component. The best fitted values and corresponding 1$σ$ deviations for the averaged phase interval: (PD=$14\substack{+15 \\ -10}$\%, PA=$108\substack{+33 \\ -54} ^{\circ}$), for Peak 1: (PD=$17\substack{+18 \\ -12}$\%, PA=$174\substack{+39 \\ -36} ^{\circ}$) and for Peak 2: (PD=$16\substack{+16 \\ -11}$\%, PA=$78\substack{+39 \\ -30} ^{\circ}$). Further more, the 3$σ$ upper limits on the polarization degree are for the averaged phase interval (55\%), Peak 1 (66\%) and Peak 2 (57\%). Finally, to illustrate the capabilities of this method in the future, we simulated two years observation to the Crab pulsar with POLAR-2. The results show that POLAR-2 is able to confirm the emission to be polarized with $5σ$ and $4σ$ confidence level if the Crab pulsar is polarized at $20\%$ and $10\%$ respectively.

preprint2022arXiv

Temperature dependence of radiation damage annealing of Silicon Photomultipliers

The last decade has increasingly seen the use of silicon photomultipliers (SiPMs) instead of photomultiplier tubes (PMTs). This is due to various advantages of the former on the latter like its smaller size, lower operating voltage, higher detection efficiency, insensitivity to magnetic fields and mechanical robustness to launch vibrations. All these features make SiPMs ideal for use on space based experiments where the detectors require to be compact, lightweight and capable of surviving launch conditions. A downside with the use of this novel type of detector in space conditions is its susceptibility to radiation damage. In order to understand the lifetime of SiPMs in space, both the damage sustained due to radiation as well as the subsequent recovery, or annealing, from this damage have to be studied. Here we present these studies for three different types of SiPMs from the Hamamatsu S13360 series. Both their behaviour after sustaining radiation equivalent to 2 years in low earth orbit in a typical mission is presented, as well as the recovery of these detectors while stored in different conditions. The storage conditions varied in temperature as well as in operating voltage. The study found that the annealing depends significantly on the temperature of the detectors with those stored at high temperatures recovering significantly faster and at recovering closer to the original performance. Additionally, no significant effect from a reasonable bias voltage on the annealing was observed. Finally the annealing rate as a function of temperature is presented along with various operating strategies for the future SiPM based astrophysical detector POLAR-2 as well as for future SiPM based space borne missions.

preprint2020arXiv

The POLAR Gamma-Ray Burst Polarization Catalog

Despite over 50 years of research, many open questions remain about the origin and nature of GRBs. Polarization measurements of the prompt emission of these extreme phenomena have long been thought to be the key to answering a range of these questions. The POLAR detector was designed to produce the first set of detailed and reliable polarization measurements in an energy range of approximately 50-500 keV. During late 2016 and early 2017, POLAR detected a total of 55 GRBs. Analysis results of 5 of these GRBs have been reported in the past. The results were found to be consistent with a low or unpolarized flux. However, previous reports by other collaborations found high levels of polarization. We study the polarization for all the 14 GRBs observed by POLAR for which statistically robust inferences are possible. Additionally, time-resolved polarization studies are performed on GRBs with sufficient apparent flux. A publicly available polarization analysis tool, developed within the 3ML framework, was used to produce statistically robust results. The method allows to combine spectral and polarimetric data from POLAR with spectral data from the Fermi GBM and Swift-BAT to jointly model the spectral and polarimetric parameters. The time integrated analysis finds all results to be compatible with a low or zero polarization with the caveat that, when time-resolved analysis is possible within individual pulses, we observe moderate polarization with a rapidly changing polarization angle. Thus, time-integrated polarization results, while pointing to lower polarization are potentially an artifact of summing over the changing polarization signal and thus, washing out the true moderate polarization. Therefore, we caution against over interpretation of any time-integrated results and encourage one to wait for more detailed polarization measurements from forthcoming missions such as POLAR-2 and LEAP.

preprint2016arXiv

Optimising a balloon-borne polarimeter in the hard X-ray domain: from the PoGOLite Pathfinder to PoGO+

PoGOLite is a balloon-borne hard X-ray polarimeter dedicated to the study of point sources. Compton scattered events are registered using an array of plastic scintillator units to determine the polarisation of incident X-rays in the energy range 20 - 240 keV. In 2013, a near circumpolar balloon flight of 14 days duration was completed after launch from Esrange, Sweden, resulting in a measurement of the linear polarisation of the Crab emission. Building on the experience gained from this Pathfinder flight, the polarimeter is being modified to improve performance for a second flight in 2016. Such optimisations, based on Geant4 Monte Carlo simulations, take into account the source characteristics, the instrument response and the background environment which is dominated by atmospheric neutrons. This paper describes the optimisation of the polarimeter and details the associated increase in performance. The resulting design, PoGO+, is expected to improve the Minimum Detectable Polarisation (MDP) for the Crab from 19.8% to 11.1% for a 5 day flight. Assuming the same Crab polarisation fraction as measured during the 2013 flight, this improvement in MDP will allow a 5σ constrained result. It will also allow the study of the nebula emission only (Crab off-pulse) and Cygnus X-1 if in the hard state.

preprint2014arXiv

PoGOLino: a scintillator-based balloon-borne neutron detector

PoGOLino is a balloon-borne scintillator-based experiment developed to study the largely unexplored high altitude neutron environment at high geomagnetic latitudes. The instrument comprises two detectors that make use of LiCAF, a novel neutron sensitive scintillator, sandwiched by BGO crystals for background reduction. The experiment was launched on March 20th 2013 from the Esrange Space Centre, Northern Sweden (geomagnetic latitude of $65^\circ$), for a three hour flight during which the instrument took data up to an altitude of 30.9 km. The detector design and ground calibration results are presented together with the measurement results from the balloon flight.

preprint2013arXiv

A Balloon-borne Measurement of High Latitude Atmospheric Neutrons Using a LiCAF Neutron Detector

PoGOLino is a scintillator-based neutron detector. Its main purpose is to provide data on the neutron flux in the upper stratosphere at high latitudes at thermal and nonthermal energies for the PoGOLite instrument. PoGOLite is a balloon borne hard X-ray polarimeter for which the main source of background stems from high energy neutrons. No measurements of the neutron environment for the planned flight latitude and altitude exist. Furthermore this neutron environment changes with altitude, latitude and solar activity, three variables that will vary throughout the PoGOLite flight. PoGOLino was developed to study the neutron environment and the influences from these three variables upon it. PoGOLino consists of two Europium doped Lithium Calcium Aluminium Fluoride (Eu:LiCAF) scintillators, each of which is sandwiched between 2 Bismuth Germanium Oxide (BGO) scintillating crystals, which serve to veto signals produced by gamma-rays and charged particles. This allows the neutron flux to be measured even in high radiation environments. Measurements of neutrons in two separate energy bands are achieved by placing one LiCAF detector inside a moderating polyethylene shield while the second detector remains unshielded. The PoGOLino instrument was launched on March 20th 2013 from the Esrange Space Center in Northern Sweden to an altitude of 30.9 km. A description of the detector design and read-out system is presented. A detailed set of simulations of the atmospheric neutron environment performed using both PLANETOCOSMICS and Geant4 will also be described. The comparison of the neutron flux measured during flight to predictions based on these simulations will be presented and the consequences for the PoGOLite background will be discussed.

preprint2013arXiv

Balloon-borne hard X-ray polarimetry with PoGOLite

PoGOLite is a hard X-ray polarimeter operating in the 25-100 keV energy band. The instrument design is optimised for the observation of compact astrophysical sources. Observations are conducted from a stabilised stratospheric balloon platform at an altitude of approximately 40 km. The primary targets for first balloon flights of a reduced effective area instrument are the Crab and Cygnus-X1. The polarisation of incoming photons is determined using coincident Compton scattering and photo-absorption events reconstructed in an array of plastic scintillator detector cells surrounded by a bismuth germanate oxide (BGO) side anticoincidence shield and a polyethylene neutron shield. A custom attitude control system keeps the polarimeter field-of-view aligned to targets of interest, compensating for sidereal motion and perturbations such as torsional forces in the balloon rigging. An overview of the PoGOLite project is presented and the outcome of the ill-fated maiden balloon flight is discussed.