Researcher profile

Mengzhou Li

Mengzhou Li contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2023arXiv

Photon-counting CT thermometry via material decomposition and machine learning

Thermal ablation procedures, such as high intensity focused ultrasound (HIFU) and Radiofrequency Ablation (RFA), are often used to eliminate tumors by minimally invasively heating a focal region. For this task, real-time 3D temperature visualization is key to target the diseased tissues while minimizing damage to the surroundings. Current CT thermometry is based on energy-integrated CT, tissue-specific experimental data, and linear relationships between attenuation and temperature. In this letter, we develop a novel approach using photon-counting CT for material decomposition and a neural network to predict temperature based on thermal characteristics of base materials and spectral tomographic measurements of a volume of interest. In our feasibility study, distilled water, 50 mM CaCl2, and 600 mM CaCl2 are chosen as the base materials. Their attenuations are measured in four discrete energy bins at various temperatures. The neural network trained on the experimental data achieves a mean absolute error of 1.80 °C and 3.97 °C on 300 mM CaCl2 and a milk-based protein shake respectively. These experimental results indicate that our approach is promising for handling nonlinear thermal properties for materials that are similar or dissimilar to our base materials.

preprint2022arXiv

Suppression of Correlated Noise with Similarity-based Unsupervised Deep Learning

Image denoising is a prerequisite for downstream tasks in many fields. Low-dose and photon-counting computed tomography (CT) denoising can optimize diagnostic performance at minimized radiation dose. Supervised deep denoising methods are popular but require paired clean or noisy samples that are often unavailable in practice. Limited by the independent noise assumption, current unsupervised denoising methods cannot process correlated noises as in CT images. Here we propose the first-of-its-kind similarity-based unsupervised deep denoising approach, referred to as Noise2Sim, that works in a nonlocal and nonlinear fashion to suppress not only independent but also correlated noises. Theoretically, Noise2Sim is asymptotically equivalent to supervised learning methods under mild conditions. Experimentally, Nosie2Sim recovers intrinsic features from noisy low-dose CT and photon-counting CT images as effectively as or even better than supervised learning methods on practical datasets visually, quantitatively and statistically. Noise2Sim is a general unsupervised denoising approach and has great potential in diverse applications.

preprint2022arXiv

Top-level Design and Simulated Performance of the First Portable CT-MR scanner

Multi-modality imaging hardware can be integrated in a single gantry to collect diverse datasets for complementary information and spatiotemporal correlation, with excellent examples including PET-CT and PET-MRI. However, there is no CT-MRI prototype up to today due to technical challenges and associated cost-benefit considerations. Thanks to the rapid development of medical imaging, it becomes feasible now to integrate cost-effective CT and MRI imagers together for portability, popularity, and point of care. In this paper, we present the top-level design of the first portable CT-MRI system and evaluate its imaging performance via realistic numerical simulations. In this CT-MRI system, the magnet made of two NdFeB rings of about 40.0 cm radius forms a magnetic field of about 57 mT at the isocenter and has a gap of 11.3 cm to accommodate the rotating CT gantry. The targeted MR imaging field of view (FOV) is a sphere of ~15 cm in diameter and that of CT is approximately 20 cm diameter in axial direction and 5 cm in longitudinal direction. Our results show a great potential of such a hybrid system. The proposed CT-MRI system will be valuable in applications such as imaging in underdeveloped countries, disaster scenes and battle fields.

preprint2021arXiv

Soft Autoencoder and Its Wavelet Adaptation Interpretation

Recently, deep learning becomes the main focus of machine learning research and has greatly impacted many important fields. However, deep learning is criticized for lack of interpretability. As a successful unsupervised model in deep learning, the autoencoder embraces a wide spectrum of applications, yet it suffers from the model opaqueness as well. In this paper, we propose a new type of convolutional autoencoders, termed as Soft Autoencoder (Soft-AE), in which the activation functions of encoding layers are implemented with adaptable soft-thresholding units while decoding layers are realized with linear units. Consequently, Soft-AE can be naturally interpreted as a learned cascaded wavelet shrinkage system. Our denoising experiments demonstrate that Soft-AE not only is interpretable but also offers a competitive performance relative to its counterparts. Furthermore, we propose a generalized linear unit (GenLU) to make an autoencoder more adaptive in nonlinearly filtering images and data, such as denoising and deblurring.

preprint2020arXiv

Clinical Micro-CT Empowered by Interior Tomography, Robotic Scanning, and Deep Learning

While micro-CT systems are instrumental in preclinical research, clinical micro-CT imaging has long been desired with cochlear implantation as a primary example. The structural details of the cochlear implant and the temporal bone require a significantly higher image resolution than that (about 0.2 mm) provided by current medical CT scanners. In this paper, we propose a clinical micro-CT (CMCT) system design integrating conventional spiral cone-beam CT, contemporary interior tomography, deep learning techniques, and technologies of micro-focus X-ray source, photon-counting detector (PCD), and robotic arms for ultrahigh resolution localized tomography of a freely-selected volume of interest (VOI) at a minimized radiation dose level. The whole system consists of a standard CT scanner for a clinical CT exam and VOI specification, and a robotic-arm based micro-CT scanner for a local scan at much higher spatial and spectral resolution as well as much reduced radiation dose. The prior information from global scan is also fully utilized for background compensation to improve interior tomography from local data for accurate and stable VOI reconstruction. Our results and analysis show that the proposed hybrid reconstruction algorithm delivers superior local reconstruction, being insensitive to the misalignment of the isocenter position and initial view angle in the data/image registration while the attenuation error caused by scale mismatch can be effectively addressed with bias correction. These findings demonstrate the feasibility of our system design. We envision that deep learning techniques can be leveraged for optimized imaging performance. With high resolution imaging, high dose efficiency and low system cost synergistically, our proposed CMCT system has great potentials in temporal bone imaging as well as various other clinical applications.

preprint2020arXiv

Low-dimensional Manifold Constrained Disentanglement Network for Metal Artifact Reduction

Deep neural network based methods have achieved promising results for CT metal artifact reduction (MAR), most of which use many synthesized paired images for training. As synthesized metal artifacts in CT images may not accurately reflect the clinical counterparts, an artifact disentanglement network (ADN) was proposed with unpaired clinical images directly, producing promising results on clinical datasets. However, without sufficient supervision, it is difficult for ADN to recover structural details of artifact-affected CT images based on adversarial losses only. To overcome these problems, here we propose a low-dimensional manifold (LDM) constrained disentanglement network (DN), leveraging the image characteristics that the patch manifold is generally low-dimensional. Specifically, we design an LDM-DN learning algorithm to empower the disentanglement network through optimizing the synergistic network loss functions while constraining the recovered images to be on a low-dimensional patch manifold. Moreover, learning from both paired and unpaired data, an efficient hybrid optimization scheme is proposed to further improve the MAR performance on clinical datasets. Extensive experiments demonstrate that the proposed LDM-DN approach can consistently improve the MAR performance in paired and/or unpaired learning settings, outperforming competing methods on synthesized and clinical datasets.

preprint2020arXiv

X-ray Photon-Counting Data Correction through Deep Learning

X-ray photon-counting detectors (PCDs) are drawing an increasing attention in recent years due to their low noise and energy discrimination capabilities. The energy/spectral dimension associated with PCDs potentially brings great benefits such as for material decomposition, beam hardening and metal artifact reduction, as well as low-dose CT imaging. However, X-ray PCDs are currently limited by several technical issues, particularly charge splitting (including charge sharing and K-shell fluorescence re-absorption or escaping) and pulse pile-up effects which distort the energy spectrum and compromise the data quality. Correction of raw PCD measurements with hardware improvement and analytic modeling is rather expensive and complicated. Hence, here we proposed a deep neural network based PCD data correction approach which directly maps imperfect data to the ideal data in the supervised learning mode. In this work, we first establish a complete simulation model incorporating the charge splitting and pulse pile-up effects. The simulated PCD data and the ground truth counterparts are then fed to a specially designed deep adversarial network for PCD data correction. Next, the trained network is used to correct separately generated PCD data. The test results demonstrate that the trained network successfully recovers the ideal spectrum from the distorted measurement within $\pm6\%$ relative error. Significant data and image fidelity improvements are clearly observed in both projection and reconstruction domains.