Researcher profile

Meghdoot Mozumder

Meghdoot Mozumder contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2023arXiv

Utilising nanosecond sources in diffuse optical tomography

Diffuse optical tomography (DOT) use near-infrared light for imaging optical properties of biological tissues. Time-domain DOT systems use pulsed lasers and measure time-varying temporal point spread function (TPSF), carrying information from both superficial and deep layers of imaged target. In this work, feasibility of nanosecond scale light pulses as sources for time-domain DOT is studied. Nanosecond sources enable using relatively robust measurement setups with standard analog-to-digital converter waveform digitizers, such as digital oscilloscopes. However, this type of systems have variations in source pulses and limited temporal sampling, that could limit their usage. In this work, these different aspects and possible limitations were studied with simulations and experiments. Simulations showed that information carried by time-domain data of diffuse medium is on low frequencies. This enables usage of relatively slow response time measurement electronics, and image processing using Fourier-transformed time-domain data. Furthermore, the temporal sampling in measurements needs to be high enough to capture the TPSF, but this rate can be achieved with standard digital oscilloscopes. It was shown that, although variations in light pulses of nanosecond lasers are larger than those of picosecond sources, they do not affect significantly on image quality. In this work, a prototype time-domain DOT experimental system utilising a high-energy nanosecond laser was constructed. The system consisted of a nanosecond Nd-YAG laser combined with optical parametric oscillator for light input, and avalanche photodetector and high-bandwidth oscilloscope for TPSF measurements. The system was used in both absolute and difference imaging of two phantoms. The experiments verified that both absorbing and scattering objects can be reconstructed with time-domain DOT using a nanosecond laser.

preprint2015arXiv

Approximate Marginalization of Absorption and Scattering in Fluorescence Diffuse Optical Tomography

In fluorescence diffuse optical tomography (fDOT), the reconstruction of the fluorophore concentration inside the target body is usually carried out using a normalized Born approximation model where the measured fluorescent emission data is scaled by measured excitation data. One of the benefits of the model is that it can tolerate inaccuracy in the absorption and scattering distributions that are used in the construction of the forward model to some extent. In this paper, we employ the recently proposed Bayesian approximation error approach to fDOT for compensating for the modeling errors caused by the inaccurately known optical properties of the target in combination with the normalized Born approximation model. The approach is evaluated using a simulated test case with different amount of error in the optical properties. The results show that the Bayesian approximation error approach improves the tolerance of fDOT imaging against modeling errors caused by inaccurately known absorption and scattering of the target.