Source author record

Maxime Jacquet

Maxime Jacquet appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

A 100 ps TOF Detection System for On-Line Range- Monitoring in Hadrontherapy

The accuracy of hadrontherapy treatment is currently limited by ion-range uncertainties. In order to fully exploit the potential of this technique, we propose the development of a novel system for online control of particle therapy, based on TOF-resolved (time-of-flight) Prompt Gamma (PG) imaging with 100 ps time resolution. Our aim is to detect a possible deviation of the proton range with respect to treatment planning within the first few irradiation spots at the beginning of the session. The system consists of a diamond-based beam hodoscope for single proton tagging, operated in time coincidence with one or more gamma detectors placed downstream of the patient. The TOF between the proton time of arrival in the hodoscope and the PG detection time provides an indirect measurement of the proton range in the patient with a precision strictly related to the system time resolution. With a single ~38 cm$^{3}$ BaF2 detector placed at 15 cm from a heterogeneous PMMA target, we obtained a coincidence time resolution of 101 ps (rms). This system allowed us to measure the thickness and position of an air cavity within a PMMA target, and the associated proton range shift: a 3 mm shift can be detected at 2$σ$ confidence level within a single large irradiation spot (~10$^{8}$ protons). We are currently conceiving a multi-channel PG timing detector with 3D target coverage. Each pixel will provide the PG detection time and its hit position, that can be used to reconstruct the 3D distribution of PG vertices in the patient. Our approach does not require collimation and allows to dramatically increase the detection efficiency. Since both signal detection and background rejection are based on TOF, the constraints on energy resolution can be relaxed to further improve time resolution.

preprint2015arXiv

Quantum vacuum emission from a refractive index front

A moving boundary separating two otherwise homogeneous regions of a dielectric is known to emit radiation from the quantum vacuum. An analytical framework based on the Hopfield model, describing a moving refractive index step in 1+1 dimensions for realistic dispersive media has been developed in [1]. We expand the use of this model to calculate explicitly spectra of all modes of positive and negative norm. Furthermore, for lower step heights we obtain a novel set of mode configurations. This leads to a realistic emission spectrum featuring black hole- and white hole emission for different frequencies. We also present spectra as measured in the laboratory frame that include all modes, in particular a dominant negative norm mode, which is the partner mode in any Hawking-type emission. We find that the emission spectrum is highly structured into intervals of emission with black hole-, white hole-, and no horizons. Finally we estimate the number of photons emitted as a function of the step height and find a power law of 2.5 for low step heights.