Source author record

Matt Pyle

Matt Pyle appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

A Search for Low-mass Dark Matter via Bremsstrahlung Radiation and the Migdal Effect in SuperCDMS

In this paper, we present a re-analysis of SuperCDMS data using a profile likelihood approach to search for sub-GeV dark matter particles (DM) through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that would otherwise be undetectable through the DM-nucleon elastic scattering channel, given the energy threshold of current experiments. We exclude DM masses down to $220~\textrm{MeV}/c^2$ at $2.7 \times 10^{-30}~\textrm{cm}^2$ via the bremsstrahlung channel. The Migdal channel search excludes DM masses down to $30~\textrm{MeV}/c^2$ at $5.0 \times 10^{-30}~\textrm{cm}^2$.

preprint2022arXiv

Calorimetric Detection of Dark Matter

Dark matter direct detection experiments are designed to look for the scattering of dark matter particles that are assumed to move with virial velocities $\sim 10^{-3}$. At these velocities, the energy deposition in the detector is large enough to cause ionization/scintillation, forming the primary class of signatures looked for in such experiments. These experiments are blind to a large class of dark matter models where the dark matter has relatively large scattering cross-sections with the standard model, resulting in the dark matter undergoing multiple scattering with the atmosphere and the rock overburden, and thus slowing down considerably before arriving at underground detectors. We propose to search for these kinds of dark matter by looking for the anomalous heating of a well shielded and sensitive calorimeter. In this detector concept, the dark matter is thermalized with the rock overburden but is able to pierce through the thermal shields of the detector causing anomalous heating. Using the technologies under development for EDELWEISS and SuperCDMS, we estimate the sensitivity of such a calorimetric detector. In addition to models with large dark matter - standard model interactions, these detectors also have the ability to probe dark photon dark matter.

preprint2016arXiv

Detecting Superlight Dark Matter with Fermi-Degenerate Materials

We examine in greater detail the recent proposal of using superconductors for detecting dark matter as light as the warm dark matter limit of O(keV). Detection of such light dark matter is possible if the entire kinetic energy of the dark matter is extracted in the scattering, and if the experiment is sensitive to O(meV) energy depositions. This is the case for Fermi-degenerate materials in which the Fermi velocity exceeds the dark matter velocity dispersion in the Milky Way of ~10^-3. We focus on a concrete experimental proposal using a superconducting target with a transition edge sensor in order to detect the small energy deposits from the dark matter scatterings. Considering a wide variety of constraints, from dark matter self-interactions to the cosmic microwave background, we show that models consistent with cosmological/astrophysical and terrestrial constraints are observable with such detectors. A wider range of viable models with dark matter mass below an MeV is available if dark matter or mediator properties (such as couplings or masses) differ at BBN epoch or in stellar interiors from those in superconductors. We also show that metal targets pay a strong in-medium suppression for kinetically mixed mediators; this suppression is alleviated with insulating targets.

preprint2016arXiv

SuperCDMS SNOLAB Low-Mass Detectors: Ultra-Sensitive Phonon Calorimeters for a Sub-GeV Dark Matter Search

We present the technical design for the SuperCDMS high-voltage, low-mass dark matter detectors, designed to be sensitive to dark matter down to 300 MeV/$c^2$ in mass and resolve individual electron-hole pairs from low-energy scattering events in high-purity Ge and Si crystals. In this paper we discuss some of the studies and technological improvements which have allowed us to design such a sensitive detector, including advances in phonon sensor design and detector simulation. With this design we expect to achieve better than 10 eV (5 eV) phonon energy resolution in our Ge (Si) detectors, and recoil energy resolution below 1eV by exploiting Luke-Neganov phonon generation of charges accelerated in high fields.

preprint2015arXiv

Optimized Designs for Very Low Temperature Massive Calorimeters

The baseline energy-resolution performance for the current generation of large-mass, low-temperature calorimeters (utilizing TES and NTD sensor technologies) is $>2$ orders of magnitude worse than theoretical predictions. A detailed study of several calorimetric detectors suggests that a mismatch between the sensor and signal bandwidths is the primary reason for suppressed sensitivity. With this understanding, we propose a detector design in which a thin-film Au pad is directly deposited onto a massive absorber that is then thermally linked to a separately fabricated TES chip via an Au wirebond, providing large electron-phonon coupling (i.e. high signal bandwidth), ease of fabrication, and cosmogenic background suppression. Interestingly, this design strategy is fully compatible with the use of hygroscopic crystals (NaI) as absorbers. An 80-mm diameter Si light detector based upon these design principles, with potential use in both dark matter and neutrinoless double beta decay, has an estimated baseline energy resolution of 0.35 eV, 20$\times$ better than currently achievable. A 1.75 kg ZnMoO$_{4}$ large-mass calorimeter would have a 3.5 eV baseline resolution, 1000$\times$ better than currently achieved with NTDs with an estimated position dependence $\frac{ΔE}{E}$ of 6$\times$10$^{-4}$. Such minimal position dependence is made possible by forcing the sensor bandwidth to be much smaller than the signal bandwidth. Further, intrinsic event timing resolution is estimated to be $\sim$170 $μ$s for 3 MeV recoils in the phonon detector, satisfying the event-rate requirements of large $Q_{ββ}$ next-generation neutrinoless double beta decay experiments. Quiescent bias power for both of these designs is found to be significantly larger than parasitic power loads achieved in the SPICA/SAFARI infrared bolometers.