Researcher profile

Masaaki Kitaguchi

Masaaki Kitaguchi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

A Novel Nuclear Emulsion Detector for Measurement of Quantum States of Ultracold Neutrons in the Earth's Gravitational Field

Hypothetical short-range interactions could be detected by measuring the wavefunctions of ultracold neutrons (UCNs) on a mirror bounded by the Earth's gravitational field. The Searches require detectors with higher spatial resolution. We are developing a UCN detector for the with a high spatial resolution, which consists of a Si substrate, a thin converter layer including $^{10}$B$_{4}$C, and a layer of fine-grained nuclear emulsion. Its resolution was estimated to be less than 100 nm by fitting tracks of either $^{7}$Li nuclei or $α$-particles, which were created when neutrons interacted with the $^{10}$B$_{4}$C layer. For actual measurements of the spatial distributions, the following two improvements were made: The first was to establish a method to align microscopic images with high accuracy within a wide region of 65 mm $\times$ 0.2 mm. We created reference marks of 1 $μ$m and 5 $μ$m diameter with an interval of 50 $μ$m and 500 $μ$m, respectively, on the Si substrate by electron beam lithography and realized a position accuracy of less than 30 nm. The second was to build a holder that could maintain the atmospheric pressure around the nuclear emulsion to utilize it under vacuum during exposure to UCNs. The intrinsic resolution of the improved detector was estimated by evaluating the blur of a transmission image of a gadolinium grating taken by cold neutrons as better than 0.56 $\pm$ 0.08 $μ$m, which included the grating accuracy. A test exposure to UCNs was conducted to obtain the spatial distribution of UCNs in the Earth's gravitational field. Although the test was successful, a blurring of 6.9 $μ$m was found in the measurements, compared with a theoretical curve. We identified the blurring caused by the refraction of UCNs due to the roughness of the upstream surface of the substrate. Polishing of the surface makes the resolution less than 100 nm.

preprint2022arXiv

Displacement-noise-free neutron interferometer for gravitational wave detection using a single Mach-Zehnder configuration

The improvement of sensitivity to gravitational waves (GWs) at lower frequencies is still challenging on account of displacement noise. One of the solutions is the neutron displacement-noise-free interferometer (DFI). We focus on a simplification of the detector configuration by taking advantage of the ability to adjust the neutron speed depending on the configuration. The new configuration consists of two beamsplitters and two mirrors, which constitute a single Mach-Zehnder interferometer (MZI). It is simpler than the configuration with two MZIs in previous research. All displacement noise of mirrors and beamsplitters can be canceled in the frequency domain. This cancellation can be explained intuitively using a phasor diagram.

preprint2022arXiv

Neutron displacement noise-free interferometer for gravitational-wave detection

An interferometer design that cancels all displacement noises of its test masses and maintains a gravitational-wave (GW) signal by combining multiple detector signals is called a displacement noise-free interferometer (DFI). The idea has been considered previously for a laser interferometer. However, a limitation of a laser DFI is that its sensitive frequency band is too high for astrophysical GW sources, $\sim 10^5\,{\rm Hz}$ even for a kilometer-sized interferometer. To circumvent this limitation, in this paper, we propose a neutron DFI, in which neutrons are used instead of light. Since neutrons have velocities much lower than the speed of light, the sensitive frequency band of a neutron DFI can be lowered down to $\sim 10^{-1}\,{\rm Hz}$. Therefore, a neutron DFI can be utilized for detecting GWs that are inaccessible by an ordinary laser interferometer on the ground.