Researcher profile

Martijn Warnier

Martijn Warnier contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
10works
0followers
8topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2020arXiv

SOS -- Self-Organization for Survival: Introducing fairness in emergency communication to save lives

Communication is crucial when disasters isolate communities of people and rescue is delayed. Such delays force citizens to be first responders and form small rescue teams. Rescue teams require reliable communication, particularly in the first 72 hours, which is challenging due to damaged infrastructure and electrical blackouts. We design a peer-to-peer communication network that meets these challenges. We introduce the concept of participatory fairness: equal communication opportunities for all citizens regardless of initial inequality in phone battery charge. Our value-sensitive design approach achieves an even battery charge distribution across phones over time and enables citizens to communicate over 72 hours. We apply the fairness principle to communication in an adapted standard Barabasi-Albert model of a scale-free network that automatically (i) assigns high-battery phones as hubs, (ii) adapts the network topology to the spatio-temporal battery charge distribution, and (iii) self-organizes to remain robust and reliable when links fail or phones leave the network. While the Barabasi-Albert model has become a widespread descriptive model, we demonstrate its use as a design principle to meet values such as fairness and systemic efficiency. Our results demonstrate that, compared to a generic peer-to-peer mesh network, the new protocol achieves (i) a longer network lifetime, (ii) an adaptive information flow, (iii) a fair distribution of battery charge, and (iv) higher participation rates. Hence, our protocol, Self-Organization for Survival ('SOS'), provides fair communication opportunities to all citizens during a disaster through self-organization. SOS enables participatory resilience and sustainability, empowering citizens to communicate when they need it most.

preprint2016arXiv

Safe and Secure Wireless Power Transfer Networks: Challenges and Opportunities in RF-Based Systems

RF-based wireless power transfer networks (WPTNs) are deployed to transfer power to embedded devices over the air via RF waves. Up until now, a considerable amount of effort has been devoted by researchers to design WPTNs that maximize several objectives such as harvested power, energy outage and charging delay. However, inherent security and safety issues are generally overlooked and these need to be solved if WPTNs are to be become widespread. This article focuses on safety and security problems related WPTNs and highlight their cruciality in terms of efficient and dependable operation of RF-based WPTNs. We provide a overview of new research opportunities in this emerging domain.

preprint2015arXiv

Distributed Monitoring for Prevention of Cascading Failures in Operational Power Grids

Electrical power grids are vulnerable to cascading failures that can lead to large blackouts. Detection and prevention of cascading failures in power grids is impor- tant. Currently, grid operators mainly monitor the state (loading level) of individual components in power grids. The complex architecture of power grids, with many interdependencies, makes it difficult to aggregate data provided by local compo- nents in a timely manner and meaningful way: monitoring the resilience with re- spect to cascading failures of an operational power grid is a challenge. This paper addresses this challenge. The main ideas behind the paper are that (i) a robustness metric based on both the topology and the operative state of the power grid can be used to quantify power grid robustness and (ii) a new proposed a distributed computation method with self-stabilizing properties can be used to achieving near real-time monitoring of the robustness of the power grid. Our con- tributions thus provide insight into the resilience with respect to cascading failures of a dynamic operational power grid at runtime, in a scalable and robust way. Com- putations are pushed into the network, making the results available at each node, allowing automated distributed control mechanisms to be implemented on top.

preprint2015arXiv

Green Wireless Power Transfer Networks

A Wireless Power Transfer Network (WPTN) aims to support devices with cable-less energy on-demand. Unfortunately, wireless power transfer itself-especially through radio frequency radiation rectification-is fairly inefficient due to decaying power with distance, antenna polarization, etc. Consequently, idle charging needs to be minimized to reduce already large costs of providing energy to the receivers and at the same time reduce the carbon footprint of WPTNs. In turn, energy saving in a WPTN can be boosted by simply switching off the energy transmitter when the received energy is too weak for rectification. Therefore in this paper we propose, and experimentally evaluate, two "green" protocols for the control plane of static charger/mobile receiver WPTN aimed at optimizing the charger workflow to make WPTN green. Those protocols are: 'beaconing', where receivers advertise their presence to WPTN, and 'probing' exploiting the receiver feedback from WTPN on the level of received energy. We demonstrate that both protocols reduce the unnecessary WTPN uptime, however trading it for the reduced energy provision, compared to the base case of 'WPTN charger always on'. For example, our system (in our experiments) saves at most approx. 80% of energy and increases 5.5 times the efficiency with only approx. 17% less energy possibly harvested.

preprint2015arXiv

Structural Vulnerability Analysis of Electric Power Distribution Grids

Power grid outages cause huge economical and societal costs. Disruptions in the power distribution grid are responsible for a significant fraction of electric power unavailability to customers. The impact of extreme weather conditions, continuously increasing demand, and the over-ageing of assets in the grid, deteriorates the safety of electric power delivery in the near future. It is this dependence on electric power that necessitates further research in the power distribution grid security assessment. Thus measures to analyze the robustness characteristics and to identify vulnerabilities as they exist in the grid are of utmost importance. This research investigates exactly those concepts- the vulnerability and robustness of power distribution grids from a topological point of view, and proposes a metric to quantify them with respect to assets in a distribution grid. Real-world data is used to demonstrate the applicability of the proposed metric as a tool to assess the criticality of assets in a distribution grid.

preprint2014arXiv

A Topological Investigation of Phase Transitions of Cascading Failures in Power Grids

Cascading failures are one of the main reasons for blackouts in electric power transmission grids. The economic cost of such failures is in the order of tens of billion dollars annually. The loading level of power system is a key aspect to determine the amount of the damage caused by cascading failures. Existing studies show that the blackout size exhibits phase transitions as the loading level increases. This paper investigates the impact of the topology of a power grid on phase transitions in its robustness. Three spectral graph metrics are considered: spectral radius, effective graph resistance and algebraic connectivity. Experimental results from a model of cascading failures in power grids on the IEEE power systems demonstrate the applicability of these metrics to design/optimize a power grid topology for an enhanced phase transition behavior of the system.

preprint2014arXiv

Does Offline Political Segregation Affect the Filter Bubble? An Empirical Analysis of Information Diversity for Dutch and Turkish Twitter Users

From a liberal perspective, pluralism and viewpoint diversity are seen as a necessary condition for a well-functioning democracy. Recently, there have been claims that viewpoint diversity is diminishing in online social networks, putting users in a "bubble", where they receive political information which they agree with. The contributions from our investigations are fivefold: (1) we introduce different dimensions of the highly complex value viewpoint diversity using political theory; (2) we provide an overview of the metrics used in the literature of viewpoint diversity analysis; (3) we operationalize new metrics using the theory and provide a framework to analyze viewpoint diversity in Twitter for different political cultures; (4) we share our results for a case study on minorities we performed for Turkish and Dutch Twitter users; (5) we show that minority users cannot reach a large percentage of Turkish Twitter users. With the last of these contributions, using theory from communication scholars and philosophers, we show how minority access is missing from the typical dimensions of viewpoint diversity studied by computer scientists and the impact it has on viewpoint diversity analysis.

preprint2013arXiv

MATCASC: A tool to analyse cascading line outages in power grids

Blackouts in power grids typically result from cascading failures. The key importance of the electric power grid to society encourages further research into sustaining power system reliability and developing new methods to manage the risks of cascading blackouts. Adequate software tools are required to better analyze, understand, and assess the consequences of the cascading failures. This paper presents MATCASC, an open source MATLAB based tool to analyse cascading failures in power grids. Cascading effects due to line overload outages are considered. The applicability of the MATCASC tool is demonstrated by assessing the robustness of IEEE test systems and real-world power grids with respect to cascading failures.

preprint2013arXiv

Structural Vulnerability Assessment of Electric Power Grids

Cascading failures are the typical reasons of black- outs in power grids. The grid topology plays an important role in determining the dynamics of cascading failures in power grids. Measures for vulnerability analysis are crucial to assure a higher level of robustness of power grids. Metrics from Complex Networks are widely used to investigate the grid vulnerability. Yet, these purely topological metrics fail to capture the real behaviour of power grids. This paper proposes a metric, the effective graph resistance, as a vulnerability measure to de- termine the critical components in a power grid. Differently than the existing purely topological measures, the effective graph resistance accounts for the electrical properties of power grids such as power flow allocation according to Kirchoff laws. To demonstrate the applicability of the effective graph resistance, a quantitative vulnerability assessment of the IEEE 118 buses power system is performed. The simulation results verify the effectiveness of the effective graph resistance to identify the critical transmission lines in a power grid.

preprint2013arXiv

The Impact of the Topology on Cascading Failures in Electric Power Grids

Cascading failures are one of the main reasons for blackouts in power transmission grids. The topology of a power grid, together with its operative state determine, for the most part, the robustness of the power grid against cascading failures. Secure electrical power supply requires, together with careful operation, a robust design of the electrical power grid topology. This paper investigates the impact of a power grid topology on its robustness against cascading failures. Currently, the impact of the topology on a grid robustness is mainly assessed by using purely topological approaches that fail to capture the essence of electric power flow. This paper proposes a metric, the effective graph resistance, that relates the topology of a power grid to its robustness against cascading failures by deliberate attacks, while also taking the fundamental characteristics of the electric power grid into account such as power flow allocation according to Kirchoff Laws. Experimental verification shows that the proposed metric anticipates the grid robustness accurately. The proposed metric is used to optimize a grid topology for a higher level of robustness. To demonstrate its applicability, the metric is applied on the IEEE 118 bus power system to improve its robustness against cascading failures.