Researcher profile

Frances M. T. Brazier

Frances M. T. Brazier contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

SOS -- Self-Organization for Survival: Introducing fairness in emergency communication to save lives

Communication is crucial when disasters isolate communities of people and rescue is delayed. Such delays force citizens to be first responders and form small rescue teams. Rescue teams require reliable communication, particularly in the first 72 hours, which is challenging due to damaged infrastructure and electrical blackouts. We design a peer-to-peer communication network that meets these challenges. We introduce the concept of participatory fairness: equal communication opportunities for all citizens regardless of initial inequality in phone battery charge. Our value-sensitive design approach achieves an even battery charge distribution across phones over time and enables citizens to communicate over 72 hours. We apply the fairness principle to communication in an adapted standard Barabasi-Albert model of a scale-free network that automatically (i) assigns high-battery phones as hubs, (ii) adapts the network topology to the spatio-temporal battery charge distribution, and (iii) self-organizes to remain robust and reliable when links fail or phones leave the network. While the Barabasi-Albert model has become a widespread descriptive model, we demonstrate its use as a design principle to meet values such as fairness and systemic efficiency. Our results demonstrate that, compared to a generic peer-to-peer mesh network, the new protocol achieves (i) a longer network lifetime, (ii) an adaptive information flow, (iii) a fair distribution of battery charge, and (iv) higher participation rates. Hence, our protocol, Self-Organization for Survival ('SOS'), provides fair communication opportunities to all citizens during a disaster through self-organization. SOS enables participatory resilience and sustainability, empowering citizens to communicate when they need it most.

preprint2014arXiv

A Topological Investigation of Phase Transitions of Cascading Failures in Power Grids

Cascading failures are one of the main reasons for blackouts in electric power transmission grids. The economic cost of such failures is in the order of tens of billion dollars annually. The loading level of power system is a key aspect to determine the amount of the damage caused by cascading failures. Existing studies show that the blackout size exhibits phase transitions as the loading level increases. This paper investigates the impact of the topology of a power grid on phase transitions in its robustness. Three spectral graph metrics are considered: spectral radius, effective graph resistance and algebraic connectivity. Experimental results from a model of cascading failures in power grids on the IEEE power systems demonstrate the applicability of these metrics to design/optimize a power grid topology for an enhanced phase transition behavior of the system.

preprint2013arXiv

Structural Vulnerability Assessment of Electric Power Grids

Cascading failures are the typical reasons of black- outs in power grids. The grid topology plays an important role in determining the dynamics of cascading failures in power grids. Measures for vulnerability analysis are crucial to assure a higher level of robustness of power grids. Metrics from Complex Networks are widely used to investigate the grid vulnerability. Yet, these purely topological metrics fail to capture the real behaviour of power grids. This paper proposes a metric, the effective graph resistance, as a vulnerability measure to de- termine the critical components in a power grid. Differently than the existing purely topological measures, the effective graph resistance accounts for the electrical properties of power grids such as power flow allocation according to Kirchoff laws. To demonstrate the applicability of the effective graph resistance, a quantitative vulnerability assessment of the IEEE 118 buses power system is performed. The simulation results verify the effectiveness of the effective graph resistance to identify the critical transmission lines in a power grid.

preprint2013arXiv

The Impact of the Topology on Cascading Failures in Electric Power Grids

Cascading failures are one of the main reasons for blackouts in power transmission grids. The topology of a power grid, together with its operative state determine, for the most part, the robustness of the power grid against cascading failures. Secure electrical power supply requires, together with careful operation, a robust design of the electrical power grid topology. This paper investigates the impact of a power grid topology on its robustness against cascading failures. Currently, the impact of the topology on a grid robustness is mainly assessed by using purely topological approaches that fail to capture the essence of electric power flow. This paper proposes a metric, the effective graph resistance, that relates the topology of a power grid to its robustness against cascading failures by deliberate attacks, while also taking the fundamental characteristics of the electric power grid into account such as power flow allocation according to Kirchoff Laws. Experimental verification shows that the proposed metric anticipates the grid robustness accurately. The proposed metric is used to optimize a grid topology for a higher level of robustness. To demonstrate its applicability, the metric is applied on the IEEE 118 bus power system to improve its robustness against cascading failures.