Source author record

Marta Molinas

Marta Molinas appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

Marine Integrated Energy Microgrids

Marine sector decarbonization is another important battlefield for meeting the goal of climate action and ensuring the fulfillment of ambitions for a zero-emission society. Driven immediately by the policy incentives such as Energy Efficiency Design Index (EEDI) from International Maritime Organization(IMO), carbon taxation and labeling, a series of innovations centered around marine transportation are emerging from both industry and academia. As an efficient energy system form, the microgrid is playing an increasingly important role as the system constitution form for various marine energy systems. With specific concern about multi-energy integrations, the conventional definition of the microgrid needs also to be extended for an integrated energy system. In this paper, we will first introduce the extended concept of the microgrid as an integrated energy system and its applications in the marine sector, and then present the state of the art for the control, operation, and system integration for it and its clusters. The challenges and opportunities for marine integrated energy microgrids will also be discussed to shed light on future research.

preprint2022arXiv

Three-Port Impedance Model and Validation of VSCs for Stability Analysis

Modern power system is undergoing a paradigm shift from the synchronous generators-based system to the power electronics converters-dominated system. With the high penetration of converters, serious stability problems are provoked, especially the wideband oscillations. Various studies have been conducted in this respect, while most of them separate the ac-side stability with the dc-side stability. However, for the stability analysis of the hybrid AC/DC grid, it is necessary to consider the converter ac-side and dc-side, simultaneously. In this paper, the stability analysis of voltage source converters (VSCs) considering both ac and dc dynamics is carried out. At first, the three-port AC/DC admittance model of VSCs is established, and the corresponding measurement method from simulations is presented to validate its accuracy. Secondly, based on such three-port model, two stability analysis methods are presented: the one is based on the system open-loop model, where the stability can be judged via the Generalized Nyquist Criterion (GNC); the other one is based on the system closed-loop model, whose stability can be predicted through the pole-zero calculation. At last, a test AC/DC system is built in MATLAB/Simulink, by which the effectiveness of the three-port model-based stability analysis is validated.

preprint2016arXiv

A modified sequence domain impedance definition and its equivalence to the dq-domain impedance definition for the stability analysis of AC power electronic systems

Representations of AC power systems by frequency dependent impedance equivalents is an emerging technique in the dynamic analysis of power systems including power electronic converters. The technique has been applied for decades in DC-power systems, and it was recently adopted to map the impedances in AC systems. Most of the work on AC systems can be categorized in two approaches. One is the analysis of the system in the \textit{dq}-domain, whereas the other applies harmonic linearization in the phase domain through symmetric components. Impedance models based on analytical calculations, numerical simulation and experimental studies have been previously developed and verified in both domains independently. The authors of previous studies discuss the advantages and disadvantages of each domain separately, but neither a rigorous comparison nor an attempt to bridge them has been conducted. The present paper attempts to close this gap by deriving the mathematical formulation that shows the equivalence between the \textit{dq}-domain and the sequence domain impedances. A modified form of the sequence domain impedance matrix is proposed, and with this definition the stability estimates obtained with the Generalized Nyquist Criterion (GNC) become equivalent in both domains. The second contribution of the paper is the definition of a \textit{Mirror Frequency Decoupled} (MFD) system. The analysis of MFD systems is less complex than that of non-MFD systems because the positive and negative sequences are decoupled. This paper shows that if a system is incorrectly assumed to be MFD, this will lead to an erroneous or ambiguous estimation of the equivalent impedance.

preprint2016arXiv

Coupled and decoupled impedance models compared in power electronics systems

This paper provides a comparative analysis of impedance models for power electronic converters and systems for the purpose of stability investigations. Such models can be divided into either decoupled models or matrix models. A decoupled impedance model is highly appealing since the Single-Input-Single-Output (SISO) structure makes the analysis and result interpretation very simple. On the other hand, matrix impedance models are more accurate, and in some cases necessary. Previous works have applied various approximations to obtain decoupled models, and both the dq- and sequence domains have been used. This paper introduces the terms decoupled and semi-decoupled impedance models in order to have a clear classification of the available approximations. The accuracy of 4 decoupled impedance models are discussed based on the concept of Mirror Frequency Coupling (MFC). By definition the decoupled models based on sequence domain impedances will be exact for systems without MFC. In the general case, they are expected to be more accurate than the decoupled dq-impedance models. The paper defines a norm $ε$ to measure the degree of coupling in the impedance matrices. This norm equals the error in the eigenvalue loci between the matrix and semi-decoupled models. This can also be viewed as the error in the semi-decoupled Nyquist plot. An example case study consisting of a grid-connected VSC with current controller and PLL is used to compare the different methods. It is found that decoupled and semi-decoupled models in the dq-domain are only applicable in grids with very low X/R-ratio. Furthermore, it is concluded that the decoupled model in the sequence domain gives close to equal results as the semi-decoupled model.

preprint2016arXiv

Entropic Empirical Mode Decomposition

Empirical Mode Decomposition(EMD) is an adaptive data analysis technique for analyzing nonlinear and nonstationary data[1]. EMD decomposes the original data into a number of Intrinsic Mode Functions(IMFs)[1] for giving better physical insight of the data. Permutation Entropy(PE) is a complexity measure[3] function which is widely used in the field of complexity theory for analyzing the local complexity of time series. In this paper we are combining the concepts of PE and EMD to resolve the mode mixing problem observed in determination of IMFs.

preprint2016arXiv

On wind Turbine failure detection from measurements of phase currents: a permutation entropy approach

This article presents the applicability of Permutation Entropy based complexity measure of a time series for detection of fault in wind turbines. A set of electrical data from one faulty and one healthy wind turbine were analysed using traditional FastFourier analysis in addition to Permutation Entropy analysis to compare the complexity index of phase currents of the two turbines over time. The 4 seconds length data set did not reveal any low frequency in the spectra of currents, neither did they show any meaningful differences of spectrum between the two turbine currents. Permutation Entropy analysis of the current waveforms of same phases for the two turbines are found to have different complexity values over time, one of them being clearly higher than the other. The work of Yan et. al. in has found that higher entropy values related to thepresence of failure in rotary machines in his study. Following this track, further efforts will be put into relating the entropy difference found in our study to possible presence of failure in one of the wind energy conversion systems.

preprint2015arXiv

Search-Enhanced Instantaneous Frequency Detection Algorithm: A Preliminary Design

This paper presents a method developed for finding sinusoidal components within a nonlinear non-stationary time-series data using Genetic Algorithm (GA) (a global optimization technique). It is called Search-Enhanced Instantaneous Frequency Detection (SEIFD) algorithm. The GA adaptively define the configuration of the components by simulating the solution finding process as a series of genetic evolutions. The start-time, end-time, frequency, and phase of each of these components are identified once convergence in the implementation is achieved.

preprint2012arXiv

Enhanced active power filter control for nonlinear non-stationary reactive power compensation

This paper describes a method to implement Reactive Power Compensation (RPC) in power systems that possess nonlinear non-stationary current disturbances. The Empirical Mode Decomposition (EMD) introduced in the Hilbert-Huang Transform (HHT) is used to separate the disturbances from the original current waveform. These disturbances are subsequently removed. Following that, Power Factor Correction (PFC) based on the well-known p-q power theory is conducted to remove the reactive power. Both operations were implemented in a shunt Active Power Filter (APF). The EMD significantly simplifies the singulation and the removal of the current disturbances. This helps to effectively identify the fundamental current waveform. Hence, it simplifies the implementation of RPC on nonlinear non-stationary power systems.

preprint2012arXiv

Performance assessment of two active power filter control strategies in the presence of non-stationary currents

This paper describes an active power filter (APF) control strategy, which eliminates harmonics and compensates reactive power in a three-phase four-wire power system supplying non-linear unbalanced loads in the presence of non-linear non-stationary currents. Empirical Mode Decomposition (EMD) technique developed as part of the Hilbert-Huang Transform (HHT) is used to singulate the harmonics and non-linear non stationary disturbances from the load currents. The control strategy for the APF is formulated by hybridizing the so called modified p-q theory with the EMD algorithm. A four-leg split-capacitor converter controlled by hysteresis band current controller is used as an APF. The results obtained are compared with those obtained with the conventional modified p-q theory, which does not possess current harmonics or distortions separation strategy, to validate its performance.