Source author record

Atle Rygg

Atle Rygg appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2016arXiv

A modified sequence domain impedance definition and its equivalence to the dq-domain impedance definition for the stability analysis of AC power electronic systems

Representations of AC power systems by frequency dependent impedance equivalents is an emerging technique in the dynamic analysis of power systems including power electronic converters. The technique has been applied for decades in DC-power systems, and it was recently adopted to map the impedances in AC systems. Most of the work on AC systems can be categorized in two approaches. One is the analysis of the system in the \textit{dq}-domain, whereas the other applies harmonic linearization in the phase domain through symmetric components. Impedance models based on analytical calculations, numerical simulation and experimental studies have been previously developed and verified in both domains independently. The authors of previous studies discuss the advantages and disadvantages of each domain separately, but neither a rigorous comparison nor an attempt to bridge them has been conducted. The present paper attempts to close this gap by deriving the mathematical formulation that shows the equivalence between the \textit{dq}-domain and the sequence domain impedances. A modified form of the sequence domain impedance matrix is proposed, and with this definition the stability estimates obtained with the Generalized Nyquist Criterion (GNC) become equivalent in both domains. The second contribution of the paper is the definition of a \textit{Mirror Frequency Decoupled} (MFD) system. The analysis of MFD systems is less complex than that of non-MFD systems because the positive and negative sequences are decoupled. This paper shows that if a system is incorrectly assumed to be MFD, this will lead to an erroneous or ambiguous estimation of the equivalent impedance.

preprint2016arXiv

Coupled and decoupled impedance models compared in power electronics systems

This paper provides a comparative analysis of impedance models for power electronic converters and systems for the purpose of stability investigations. Such models can be divided into either decoupled models or matrix models. A decoupled impedance model is highly appealing since the Single-Input-Single-Output (SISO) structure makes the analysis and result interpretation very simple. On the other hand, matrix impedance models are more accurate, and in some cases necessary. Previous works have applied various approximations to obtain decoupled models, and both the dq- and sequence domains have been used. This paper introduces the terms decoupled and semi-decoupled impedance models in order to have a clear classification of the available approximations. The accuracy of 4 decoupled impedance models are discussed based on the concept of Mirror Frequency Coupling (MFC). By definition the decoupled models based on sequence domain impedances will be exact for systems without MFC. In the general case, they are expected to be more accurate than the decoupled dq-impedance models. The paper defines a norm $ε$ to measure the degree of coupling in the impedance matrices. This norm equals the error in the eigenvalue loci between the matrix and semi-decoupled models. This can also be viewed as the error in the semi-decoupled Nyquist plot. An example case study consisting of a grid-connected VSC with current controller and PLL is used to compare the different methods. It is found that decoupled and semi-decoupled models in the dq-domain are only applicable in grids with very low X/R-ratio. Furthermore, it is concluded that the decoupled model in the sequence domain gives close to equal results as the semi-decoupled model.