Researcher profile

Markus Gräfe

Markus Gräfe contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2026arXiv

Below-shot-noise capacity in phase estimation using nonlinear interferometers

Over the past decade, several schemes for imaging and sensing based on nonlinear interferometers have been proposed and demonstrated experimentally. These interferometers exhibit two main advantages. First, they enable probing a sample at a chosen wavelength while detecting light at a different wavelength with high efficiency (bicolor quantum imaging and sensing with undetected light). Second, they can show quantum-enhanced sensitivities below the shot-noise limit, potentially reaching Heisenberg-limited precision in parameter estimation. Here, we compare three quantum-imaging configurations using only easily accessible intensity-based measurements for phase estimation: a Yurke-type SU(1,1) interferometer, a Mandel-type induced-coherence interferometer, and a hybrid scheme that continuously interpolates between them. While an ideal Yurke interferometer can exhibit Heisenberg scaling, this advantage is known to be fragile under realistic detection constraints and in the presence of loss. We demonstrate that differential intensity detection in the Mandel interferometer provides the highest and most robust phase sensitivity among the considered schemes, reaching but not surpassing the shot-noise limit, even in the presence of loss. Intensity measurements in a Yurke-type configuration can achieve genuine sub-shot-noise sensitivity under balanced losses and moderate gain; however, their performance degrades in realistic high-gain regimes. Consequently, in this regime, the Mandel configuration with differential detection outperforms the Yurke-type setup and constitutes the most robust approach for phase estimation.

preprint2025arXiv

Noise resilient real-time phase imaging via undetected light

Quantum imaging with undetected light has recently emerged as a technique in which quantum correlations and nonlinear interferometry are combined to decouple illumination and detection paths. This approach has been more recently extended and combined with digital phase-shifting holography and off-axis holography to extract both the amplitude and phase information of a sample relying on single-photon interference. Despite these advantages, implementing the technique in real-world scenarios where the observed system is subject to environmental noise and dynamic variations remains challenging. The primary limitation lies in the inability of quantum imaging systems to retrieve object information in real time under high-noise conditions. Here, we experimentally demonstrate real-time amplitude and phase imaging in noisy environments, building upon our previous implementation of quantum off-axis holography. Our results demonstrate real-time imaging at acquisition rates up to 4~Hz, even when the noise level exceeds the signal by an order of magnitude.

preprint2022arXiv

Quantum holography with undetected light

Holography exploits the interference of light fields to obtain a systematic reconstruction of the light fields wavefronts. Classical holography techniques have been very successful in diverse areas such as microscopy, manufacturing technology, and basic science. Extending holographic methods to the level of single photons has been proven challenging, since applying classical holography techniques to this regime pose technical problems. Recently the retrieval of the spatial structure of a single photon, using another photon under experimental control with a well-characterized spatial shape as reference, was demonstrated using the intrinsically non-classical Hong-Ou-Mandel interference on a beam splitter. Here we present a method for recording a hologram of single photons without detecting the photons themselves, and importantly, with no need to use a well-characterized companion reference photon. Our approach is based on quantum interference between two-photon probability amplitudes in a nonlinear interferometer. As in classical holography, the hologram of a single photon allows retrieving the complete information about the "shape" of the photon (amplitude and phase) despite the fact that the photon is never detected.

preprint2020arXiv

Possible link between the distribution of atomic spectral lines and the radiation-matter-equilibrium in the early universe

We report on the uncanny resemblance of the global distribution of all experimentally known atomic spectral lines to the Planckian spectral distribution associated with black body radiation at a temperature of $T\approx9000\,\mathrm{K}$. This value coincides with the critical temperature of equilibrium between the respective densities of radiation and matter in the early universe.