Researcher profile

Marija Kosec

Marija Kosec contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2013arXiv

Fabrication and modeling of piezoelectric transducers for High-Frequency medical imaging

We have studied the processing of piezoelectric thick films using electrophoretic deposition (EPD) for high-frequency ultrasound applications. Lead-zirconium-titanate (PZT) particles synthetized by solid states synthesis were dispersed in ethanol using ammonium polyacrylate (PAA). The electrophoretic deposition of PZT particles was performed at a constant-current mode. PZT thick-films deposited at 1 mA for 60 seconds were sintered at 900oC for 2 hours in a PbO-controlled atmosphere. The scanning-electron microscopy (SEM) analysis shows that the thickness of PZT layer is uniform and that the pores are homogeneously distributed within the layer. The complex electrical impedance was measured and fitted by KLM scheme in order to deduce the dielectric, mechanical and piezoelectric parameters of the thick-films. The density and thickness of PZT thick films are used as inputs and the thickness coupling factor kt, dielectric constant at constant strain and resonant frequency are deduced. The results show that homogeneous PZT thick-film structures with tailored thickness and density prepared by EPD and sintering having a resonant frequency around 20 MHz can be used for noninvasive medical ultrasound imaging and diagnostics.

preprint2012arXiv

Piezoelectric nonlinearity and frequency dispersion of the direct piezoelectric response of BiFeO3 ceramics

We report on the frequency and stress dependence of the direct piezoelectric d33 coefficient in BiFeO3 ceramics. The measurements reveal considerable piezoelectric nonlinearity, i.e., dependence of d33 on the amplitude of the dynamic stress. The nonlinear response suggests a large irreversible contribution of non-180° domain walls to the piezoelectric response of the ferrite, which, at present measurement conditions, reached a maximum of 38% of the total measured d33. In agreement with this interpretation, both types of non-180° domain walls, characteristic for the rhombohedral BiFeO3, i.e., 71° and 109°, were identified in the poled ceramics using transmission electron microscopy (TEM). In support to the link between nonlinearity and non-180° domain wall contribution, we found a correlation between nonlinearity and processes leading to deppining of domain walls from defects, such as quenching from above the Curie temperature and high-temperature sintering. In addition, the nonlinear piezoelectric response of BiFeO3 showed a frequency dependence that is qualitatively different from that measured in other nonlinear ferroelectric ceramics, such as "soft" (donor-doped) Pb(Zr,Ti)O3 (PZT); possible origins of this dispersion are discussed. Finally, we show that, once released from pinning centers, the domain walls can contribute extensively to the electromechanical response of BiFeO3; in fact, the extrinsic domain-wall contribution is relatively as large as in Pb-based ferroelectric ceramics with morphotropic phase boundary (MPB) composition, such as PZT. This finding might be important in the search of new lead-free MPB compositions based on BiFeO3 as it suggests that such compositions might also exhibit large extrinsic domain-wall contribution to the piezoelectric response.

preprint2011arXiv

Large electric-field induced strain in BiFeO3 ceramics

Large bipolar strain of up to 0.36% (peak-to-peak value) was measured in BiFeO3 ceramics at low frequency (0.1 Hz) and large amplitude (140 kV/cm) of the driving field. This strain is comparable to that achievable in highly efficient Pb-based perovskite ceramics, such as Pb(Zr,Ti)O3 and Pb(Mg,Nb)O3-PbTiO3. The strain showed a strong dependence on the field frequency and is likely largely associated with domain switching involving predominantly non-180° domain walls. In addition, rearrangement of charged defects by applying electric field of low frequency depins these domain walls, resulting in a more efficient switching and, consequently, an increased response.