Source author record

Marco Petasecca

Marco Petasecca appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Hydrogenated amorphous silicon detectors for particle detection, beam flux monitoring and dosimetry in high-dose radiation environment

Hydrogenated amorphous silicon (a-Si:H) has remarkable radiation resistance properties and can be deposited on a lot of different substrates. A-Si:H based particle detectors have been built since mid 1980s as planar p-i-n or Schottky diode structures; the thickness of these detectors ranged from 1 to 50 micron. However MIP detection using planar structures has always been problematic due to the poor S/N ratio related to the high leakage current at high depletion voltage and the low charge collection efficiency. The usage of 3D detector architecture can be beneficial for the possibility to reduce inter-electrode distance and increase the thickness of the detector for larger charge generation compared to planar structures. Such a detector can be used for future hadron colliders for its radiation resistance and also for X-ray imaging. Furthermore the possibility of a-Si:H deposition on flexible materials (like kapton) can be exploited to build flexible and thin beam flux measurement detectors and x-ray dosimeters.

preprint2015arXiv

Thin silicon strip detectors for beam monitoring in Micro-beam Radiation Therapy

Microbeam Radiation Therapy (MRT) is an emerging cancer treatment that is currently being developed at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. This technique uses a highly collimated and fractionated X-ray beam array with extremely high dose rate and very small divergence, to benefit from the dose-volume effect, thus sparing healthy tissue. In case of any beam anomalies and system malfunctions, special safety measures must be installed, such as an emergency safety shutter that requires continuous monitoring of the beam intensity profile. Within the 3DMiMic project, a novel silicon strip detector that can tackle the special features of MRT, such as the extremely high spatial resolution and dose rate, has been developed to be part of the safety shutter system. The first prototypes have been successfully fabricated, and experiments aimed to demonstrate their suitability for this unique application have been performed. Design, fabrication and the experimental results as well as any identified inadequacies for future optimisation are reported and discussed in this paper.