Source author record

Marco Costa

Marco Costa appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Asymmetric Accidental Composite Dark Matter

The goal of this work is to find the simplest UV completions of Accidental Composite Dark Matter models that can dynamically generate an asymmetry for the Dark Matter candidate, the lightest dark baryon, and simultaneously annihilate the symmetric component. In this framework Dark Matter is an accidentally stable bound state of a confining $\mathrm{SU}(N)$ gauge group that can interact weakly with the visible sector. The generation of asymmetry for such candidate happens via the out-of-equilibrium decay of two flavors of a heavy scalar $ϕ$, with mass $M_ϕ> 10^{10}$ GeV. Below such scale, the models recover accidental stability, or long-livedness, of the Dark Matter candidate. The symmetric component is annihilated by residual confined interactions provided that the mass of the dark baryon is < 75 TeV.

preprint2022arXiv

Closing the window on WIMP Dark Matter

We study scenarios where Dark Matter is a weakly interacting particle (WIMP) embedded in an ElectroWeak multiplet. In particular, we consider real SU(2) representations with zero hypercharge, that automatically avoid direct detection constraints from tree-level Z-exchange. We compute for the first time all the calculable thermal masses for scalar and fermionic WIMPs, including Sommerfeld enhancement and bound states formation at leading order in gauge boson exchange and emission. WIMP masses of few hundred TeV are shown to be compatible both with s-wave unitarity of the annihilation cross-section, and perturbativity. We also provide theory uncertainties on the masses for all multiplets, which are shown to be significant for large SU(2) multiplets. We then outline a strategy to probe these scenarios at future experiments. Electroweak 3-plets and 5-plets have masses up to about 16 TeV and can efficiently be probed at a high energy muon collider. We study various experimental signatures, such as single and double gauge boson emission with missing energy, and disappearing tracks, and determine the collider energy and luminosity required to probe the thermal Dark Matter masses. Larger multiplets are out of reach of any realistic future collider, but can be tested in future gamma ray telescopes and possibly in large-exposure liquid Xenon experiments.

preprint2022arXiv

Optimization of the Gain Layer Design of Ultra-Fast Silicon Detectors

In the past few years, the need of measuring accurately the spatial and temporal coordinates of the particles generated in high-energy physics experiments has spurred a strong R\&D in the field of silicon sensors. Within these research activities, the so-called Ultra-Fast Silicon Detectors (UFSDs), silicon sensors optimized for timing based on the Low-Gain Avalanche Diode (LGAD) design, have been proposed and adopted by the CMS and ATLAS collaborations for their respective timing layers. The defining feature of the Ultra-Fast Silicon Detectors (UFSDs) is the internal multiplication mechanism, determined by the gain layer design. In this paper, the performances of several types of gain layers, measured with a telescope instrumented with a $^{90}$Sr $β$-source, are reported and compared. The measured sensors are produced by Fondazione Bruno Kessler (FBK) and Hamamatsu Photonics (HPK). The sensor yielding the best performance, both when new and irradiated, is an FBK 45\mum-thick sensor with a carbonated deep gain implant, where the carbon and the boron implants are annealed concurrently with a low thermal load. This sensor is able to achieve a time resolution of 40~ps up to a radiation fluence of~\fluence{2.5}{15}, delivering at least 5~fC of charge.

preprint2022arXiv

The physics case of a 3 TeV muon collider stage

In the path towards a muon collider with center of mass energy of 10 TeV or more, a stage at 3 TeV emerges as an appealing option. Reviewing the physics potential of such muon collider is the main purpose of this document. In order to outline the progression of the physics performances across the stages, a few sensitivity projections for higher energy are also presented. There are many opportunities for probing new physics at a 3 TeV muon collider. Some of them are in common with the extensively documented physics case of the CLIC 3 TeV energy stage, and include measuring the Higgs trilinear coupling and testing the possible composite nature of the Higgs boson and of the top quark at the 20 TeV scale. Other opportunities are unique of a 3 TeV muon collider, and stem from the fact that muons are collided rather than electrons. This is exemplified by studying the potential to explore the microscopic origin of the current $g$-2 and $B$-physics anomalies, which are both related with muons.

preprint2019arXiv

The e_LiBANS facility: a new compact thermal neutron source based on a medical electron LINAC

A new photonuclear thermal neutron facility has been developed at the Physics Department of University of Torino. The facility is based on a medical electron LINAC coupled to a compact converter and moderator assembly. A homogenous thermal neutron field of the order of 10$^6$ cm$^{-2}$s$^{-1}$ is achievable in the enclosed irradiation cavity with low gamma and fast neutron contaminations. Its intensity can be tuned varying the LINAC current. These characteristics make the source appropriate for several applications like detectors development, material studies and BNCT preclinical research. This work describes the project and the experimental characterization of the facility. This includes the measurement of the thermal neutron fluence rate, the determination of the neutron energy spectrum and of the thermal neutron field uniformity and the evaluation of the gamma contamination.