Researcher profile

Marcel Schubert

Marcel Schubert contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2026arXiv

Minimal-footprint photonic crystal nanolasers for biointegration

Photonic crystals allow unprecedented control over how light is confined, propagates, and interacts with matter. Their development has had a transformative impact on optics and physics, and they remain the central platform for both fundamental discoveries and practical photonic technologies. However, the relatively large footprint and substrate-bound nature of photonic crystal structures have so far strongly limited their use as miniature optical devices or biointegrated sensors. Here, we overcome these limitations by identifying the minimal size of a 2D photonic crystal array needed to achieve lasing and describe the fabrication of substrate-less hexagonal laser particles with an active area as small as 30 μm2. Massively parallel fabrication, robust detachment, and integration of the nanolaser particles into live cells is demonstrated. Crucially, by engineering spatial and spectral mode characteristics, we designed NIR-II probes with mode volumes on the order of tens of attolitres, an order of magnitude smaller than whispering gallery probes of similar dimensions. Such high light localization is comparable in scale to different organelles of eucaryotic cells. In the future, we expect that chemical or plasmonic functionalization of the device will enable label-free sensing of nanoscale intracellular processes, and that it shall serve as a miniature platform to exploit developments in optical and quantum sensing for chemical and biological applications.

preprint2026arXiv

Purely equatorial lasing in spherical liquid crystal polymer microlasers with engineered refractive index gradient

Liquid crystal whispering gallery mode microlasers show high sensitivity to external stimuli and distinct spectral features, rendering them ideally suited for various sensing applications. They also offer intrinsic anisotropic optical properties, which can be used to shape and manipulate light even inside spatially highly symmetric structures. Here, we report the synthesis and detailed optical characterization of a spherical bipolar liquid crystal polymer microlaser that tightly confines the optical path of whispering gallery modes to the equatorial plane. By controlled anchoring of the liquid crystal mesogens followed by polymerization, a fixed refractive index gradient is formed within the spherical microcavity. Consequently, only transverse electric (TE) modes oscillating in the equatorial plane experience the high extraordinary refractive index, allowing to confine lasing into a single plane. Furthermore, we observe that the refractive index gradient causes a characteristic splitting of the TE modes. By combining hyperspectral imaging and analytical modeling, we demonstrate that the observed splitting is caused by lifting of the energy degeneracy of higher order azimuthal laser modes, enabling direct insights into the complex interplay of refractive index gradients and resulting whispering gallery mode confinement. In addition, the unique ability to confine lasing of a spherical microbead into only a single plane makes these microlasers independent of the exact position of the pump beam, which allows consistent localized sensing especially in combination with fast point scanning microscopes or inside highly dynamic biological environments.

preprint2009arXiv

Charge mobility determination by current extraction under linear increasing voltages: the case of non-equilibrium charges and field-dependent mobilities

The method of current extraction under linear increasing voltages (CELIV) allows for the simultaneous determination of charge mobilities and charge densities directly in thin films as used in organic photovoltaic cells (OPV). In the past, it has been specifically applied to investigate the interrelation of microstructure and charge transport properties in such systems. Numerical and analytical calculations presented in this work show that the evaluation of CELIV transients with the commonly used analysis scheme is error prone once charge recombination and, possibly, field dependent charge mobilities are taken into account. The most important effects are an apparent time-dependence of charge mobilities and errors in the determined field dependencies. Our results implicate that reports on time-dependent mobility relaxation in OPV materials obtained by the CELIV technique should be carefully revisited and confirmed by other measurement methods.