4 published item(s)

preprint2016arXiv

A multiplexer for the ac/dc characterization of TES based bolometers and microcalorimeters

At SRON we are developing the Frequency Domain Multiplexing (FDM) for the read-out of the TES-based detector array for the future infrared and X-ray space mission. We describe the performances of a multiplexer designed to increase the experimental throughput in the characterisation of ultra-low noise equivalent power (NEP) TES bolometers and high energy resolving power X-ray microcalorimeters arrays under ac and dc bias. We discuss the results obtained using the TiAu TES bolometers array fabricated at SRON with measured dark NEP below $5\cdot 10^{-19}W/Hz^{1/2}$ and saturation power of several fW

preprint2016arXiv

AC bias characterization of low noise bolometers for SAFARI using an Open-Loop Frequency Domain SQUID-based multiplexer operating between 1 and 5 MHz

SRON is developing the Frequency Domain Multiplexing (FDM) readout and the ultra low NEP TES bolometers array for the infrared spectrometer SAFARI on board of the Japanese space mission SPICA. The FDM prototype of the instrument requires critical and complex optimizations. For single pixel characterization under AC bias we are developing a simple FDM system working in the frequency range from 1 to 5 MHz, based on the open loop read-out of a linearized two-stage SQUID amplifier and high Q lithographic LC resonators. We describe the details of the experimental set-up required to achieve low power loading (< 1 fW) and low noise (NEP $\sim 10^{-19} W/Hz^{1/2}$) in the TES bolometers. We conclude the paper by comparing the performance of a $4 \cdot 10^{-19} W/Hz^{1/2}$ TES bolometer measured under DC and AC bias.

preprint2016arXiv

Optical performance of an ultra-sensitive horn-coupled transition-edge-sensor bolometer with hemispherical backshort in the far infrared

The next generation of far infrared space observatories will require extremely sensitive detectors that can be realized only by combining extremely low intrinsic noise with high optical efficiency. We have measured the broad-band optical response of ultra-sensitive TES bolometers (NEP$\approx2\rm\ aW/\sqrt Hz$) in the 30--60-$μ\rm m$ band where radiation is coupled to the detectors with a few-moded conical feedhorn and a hemispherical backshort. We show that these detectors have an optical efficiency of 60% (the ratio of the power detected by the TES bolometer to the total power propagating through the feedhorn). We find that the measured optical efficiency can be understood in terms of the modes propagating through the feedhorn with the aid of a spatial mode-filtering technique.

preprint2016arXiv

Weak-Link Phenomena in AC-Biased Transition Edge Sensors

It has been recently demonstrated that superconducting transition edge sensors (TESs) behave as weak-links due to longitudinally induced superconductivity from the leads with higher Tc. In this work we study the implication of this behaviour for TES-based bolometers and microcalorimeter under ac bias. The TESs are read-out at frequencies between 1 and 5 MHz by a Frequency Domain Multiplexer based on a linearised two-stage SQUID amplifier and high- Q lithographically made superconducting LC resonators. In particular, we focus on SRON TiAu TES bolometers with a measured dark Noise Equivalent Power (NEP) of $3.2 \cdot 10^{-19} W/Hz^{1/2}$ developed for the short wavelength band for the instrument SAFARI on the SPICA telescope.