Researcher profile

Marc Bergevin

Marc Bergevin contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
8topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Improvement in light collection of a photomultiplier tube using a wavelength-shifting plate

Large-volume water-Cherenkov neutrino detectors are a light-starved environment, as each interaction produces only $\sim 50-100$ photons per MeV. As such, maximizing the light collection efficiency of the detector is vital to performance. Since Cherenkov emission is heavily weighted towards the near UV, one method to maximize overall detector light collection without increasing the number of photomultiplier tubes is to couple each tube to a wavelength-shifting plastic plate, thus shifting photon wavelengths to a regime better suited to maximize photomultiplier efficiency and potentially detecting photons that miss the photocathode. To better understand the behavior of such plates, a scan of a rectangular wavelength-shifting plate was performed, and the results were used to calculate the overall percentage improvement in light collection that could be expected for individual PMTs in a large water-Cherenkov detector. Measurements of a 15.1 in. by 11.5 in. wavelength-shifting plate using a 365 nm LED were found to increase overall light collection at the photomultiplier tube by $7.4\pm0.7\%$. A simulation tuned to reproduce these results was used to predict the behavior of a wavelength shifting plate exposed to Cherenkov spectrum light and found increases in light collection that were linear with edge length, assuming square geometries. These results demonstrate the potential of wavelength-shifting plates to increase the overall light collection efficiency in a large detector.

preprint2022arXiv

Scalability of gadolinium-doped-water Cherenkov detectors for nuclear nonproliferation

Antineutrinos are an unavoidable byproduct of the fission process. The kiloton-scale KamLAND experiment has demonstrated the capability to detect reactor antineutrinos at few-hundred-km range. But to detect or rule out the existence of a single small reactor over many km requires a large detector. So large in fact that the optical opacity of the detection medium itself becomes an important factor. If the detector is so large that photons cannot traverse across the detector medium to an optical detector, then it becomes impractical. For this reason, gadolinium-doped-water Cherenkov detectors have been proposed for large volumes, due to their appealing light-attenuation properties. Even though Cherenkov emission does not produce many photons and the energy resolution is poor, there may be a place for Gd-doped-water detectors in the far-field nuclear reactor monitoring. In this paper, we focus on the reactor discovery potential of large-volume Gd-doped-water Cherenkov detectors for nuclear nonproliferation applications. Realistic background models for the worldwide reactor flux, geo-neutrinos, cosmogenic fast neutrons, and detector-associated backgrounds are included. We calculate the detector run time required to detect a small 50-MWt reactor at a variety of stand-off distances as a function of detector size. We highlight that at present, PMT dark rate and event reconstruction algorithms are the limiting factors to extending beyond ~50-kt fiducial mass.

preprint2016arXiv

Project X: Physics Opportunities

Part 2 of "Project X: Accelerator Reference Design, Physics Opportunities, Broader Impacts". In this Part, we outline the particle-physics program that can be achieved with Project X, a staged superconducting linac for intensity-frontier particle physics. Topics include neutrino physics, kaon physics, muon physics, electric dipole moments, neutron-antineutron oscillations, new light particles, hadron structure, hadron spectroscopy, and lattice-QCD calculations. Part 1 is available as arXiv:1306.5022 [physics.acc-ph] and Part 3 is available as arXiv:1306.5024 [physics.acc-ph].