Researcher profile

Manjunatha Mahadevappa

Manjunatha Mahadevappa contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Detection and localization of Coronary Arterial Lesion with the Aid of Impedance Cardiography

In recent years, coronary artery disease is escalating and is likely to assume an epidemic proportion by 2030. Currently the reliable methods for detection of coronary arterial lesions are either conventional coronary angiogram (CAG) or MDCT (Multiple Detector Computed Tomography) coronary angiogram. Conventional CAG is an invasive procedure. Conventional CAG and CT (Computed Tomography) angiogram, both require expert supervision of either an interventional cardiologist or a radiologist. In this work, we have proposed a novel design and method for non-invasive detection and localization of coronary arterial lesion using Impedance Cardiography (ICG). The ICG signal recorded by the proposed device is used to extract feature points and compute augmentation index, amplitude and other time related parameters. The extracted features are used as input to a trained artificial neural network, for detection and prediction of coronary arterial lesions. The trained network generates specialized models, to be used for diagnosis of arterial lesions. The proposed methodology detects lesion in Left main coronary artery (LMCA), Left anterior descending artery (LAD), Diagonal branch, Left circumflex artery (LCX), and Right coronary artery (RCA) with an accuracy of 92%, 82%, 76%, 76%, 84% respectively. The proposed device could be also used by a common individual for detection of arterial lesion without any expert supervision, unassisted. The proposed algorithm eliminates the need of CAG for diagnosis of coronary arterial lesions (stenosis), and provides an insight into a new method for non-invasive monitoring of cardiovascular haemodynamics, detection and localization of coronary arterial lesion.

preprint2020arXiv

EM based Framework for Single-shot Compressive Holography

Lensless in-line holography is a simple, portable, and cost-effective method of imaging especially for the biomedical microscopy applications. We propose a multiplicative gradient descent optimization based method to obtain multi-depth imaging from a single hologram acquired in this imaging system. We further extend the method to achieve phase imaging from a single hologram. Negative-log-likelihood functional with the assumption of poisson noise has been used as the cost function to be minimized. The ill-posed nature of the problem is handled by the sparse regularization and the upper-bound constraint. The gradient descent optimization requires calculation of the partial derivative of the cost function with respect to a given estimate of the object. A method of obtaining this quantity for holography in both the cases of real object and complex object has been shown. The reconstruction method has been validated using extensive simulation and experimental studies. The comparison with the previously established iterative shrinkage/thresholding algorithm based compressive holography shows that the proposed method has the following advantages: significantly faster convergence rate, better reconstructed image quality and the ability to perform phase imaging.

preprint2020arXiv

Photonic crystal fiber for high resolution lensless in-line holographic microscopy

We propose to use high numerical aperture single mode optical fibers like photonic crystal fiber for lensless in-line holographic microscopy. Highly divergent beam helps to overcome the spatial sampling limitation of the image sensor. In this paper, a submicron lateral resolution has been demonstrated, with an imaging sensor of pixel pitch 1.12 micrometer and a photonic crystal fiber of mode field diameter 1.8 micrometer. In earlier methods of single-shot lensless imaging, submicron resolution has been obtained at very small working distance and field of view. The proposed method improves the resolution without compromising the working distance. A working distance of (but not limited to) ~1.7 mm with a field of View ~1.4 mm has been demonstrated.