Researcher profile

Mala Das

Mala Das contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2025arXiv

The Dark Matter Search at Jaduguda Underground Science Laboratory

The first run for the dark matter direct search experiment at Jaduguda Underground Science Laboratory is presented in this article. The experiment named InDEx; the Indian Dark matter search Experiment has been initiated with superheated emulsion detector consisting of the droplets of tetrafluoroethane ($C_2H_2F_4$). The detector ran for an effective period of 48.6 days at a threshold of 5.87 keV with an exposure of 2.47 kg-days. It is observed that the minimum sensitivity for the SI cross-section of $[7.939\pm(0.375)_{statistical}(^{+1.386}_{-0.909})_{systematic}]\times 10^{-39}$ $cm^2$ for fluorine appears at WIMP mass of 30.67 $GeV/c^2$. The InDEx with larger exposures is under development and yet to come in near future.

preprint2020arXiv

Probing low-mass WIMP candidates of dark matter with tetrafluoroethane superheated liquid detectors

Probing low mass (sub-GeV -- few GeV) Weakly Interacting Massive Particle (WIMP) candidates of dark matter through WIMP-induced nuclear recoils in direct detection experiments requires use of detector materials consisting of low mass target nuclei and low threshold energy. Here we explore the potential of superheated liquid detectors (SLD) with a hydrogen containing liquid, namely, tetrafluoroethane (C$_{2}$H$_{2}$F$_{4}$) (b.p.~$-26.3^\circ\,$C), as the target material for probing low mass WIMPs. It is found that few-keV level recoil energy thresholds possible for bubble nucleation by WIMP-induced $^{12}$C and $^{19}$F recoils in C$_{2}$H$_{2}$F$_{4}$ SLDs operated at atmospheric pressure and gamma-ray insensitive temperatures of $T\, \lesssim\, 35^\circ\,$C have the potential to allow WIMPs in the few-GeV mass range to be probed at a WIMP-nucleon spin-independent cross section sensitivity levels (90% C.L.) better than $4.6\times 10^{-5}\,$pb at WIMP masses down to $\sim$ 4 GeV with a total exposure of $\sim$ 1000 kg.day, provided that the ``thermodynamic efficiency" $η_{\rm T}$ that determines the bubble nucleation thresholds for the recoiling nuclei in C$_{2}$H$_{2}$F$_{4}$ is $\sim$ 50% or higher. Sensitivity to sub-GeV WIMP masses generally requires the detector to be sensitive to the WIMP-induced $^1$H recoils, which in turn requires the detector to be operated at temperatures $T\gtrsim 50^\circ\,$C and $η_{\rm T}$ close to 100%. At such relatively high temperatures (at atmospheric pressure), however, the detector would be sensitive to background gamma rays.

preprint2013arXiv

Study of low frequency acoustic signals from superheated droplet detector

The bubble nucleation process in superheated droplet detector (SDD) is associated with the emission of an acoustic pulse that can be detected by an acoustic sensor. We have studied the neutron and gamma-ray induced nucleation events in a SDD with the active liquid R-12 (CCl2F2, b.p. -29.8oC) using a condenser microphone sensor. A comparative study in the low frequency region (~ 0-10kHz) for the neutron and gamma-ray induced nucleation is presented here. From the analysis of the waveforms we observe a significant difference between the neutron and gamma-ray induced acoustic events.

preprint2013arXiv

The nucleation parameter for heavy-ion induced bubble nucleation in superheated emulsion detector

The values of the nucleation parameter, k, for bubble nucleation induced by high energy heavy ions 12C (180 MeV/u), 20Ne (400 MeV/u) and 28Si (350 MeV/u) in superheated emulsion detector are determined by comparing the experimentally obtained normalized count rates with those obtained from simulations done using the GEANT3.21 simulation code. The results show that the nucleation parameter depends on the mass number of the incident heavy ions, and decreases with increasing mass number.

preprint2010arXiv

Neutron-gamma discrimination by pulse analysis with superheated drop detector

Superheated drop detector (SDD) consisting of drops of superheated liquid of halocarbon is irradiated to neutrons and gamma-rays from 252Cf fission neutron source and 137Cs gamma source separately. The analysis of pulse height of the signals in the neutron and gamma-ray sensitive temperature provides strong information on the identification of neutron and gamma-ray induced events.

preprint2000arXiv

Superheated drop as a neutron spectrometer

Superheated drops are known to vaporise when exposed to energetic nuclear radiation since the discovery of bubble chamber. As the degree of superheat increases in a given liquid, less and less energetic neutrons are required to cause nucleation. This property of superheated liquids are being utilised to develope the neutron spectromer. A new principle of neutron spectrometry using Superheated liquid are developed and the developed principle has been tested by Am-Be neutron source.