Source author record

Mahendra Patel

Mahendra Patel appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Data-Driven Fast Frequency Control using Inverter-Based Resources

We develop and test a data-driven and area-based fast frequency control scheme, which rapidly redispatches inverter-based resources to compensate for local power imbalances within the bulk power system. The approach requires no explicit system model information, relying only on historical measurement sequences for the computation of control actions. Our technical approach fuses developments in low-gain estimator design and data-driven control to provide a model-free and practical solution for fast frequency control. Theoretical results and extensive simulation scenarios on a three area system are provided to support the approach.

preprint2022arXiv

Hierarchical Frequency and Voltage Control using Prioritized Utilization of Inverter Based Resources

We propose a novel hierarchical frequency and voltage control design for multi-area power system integrated with inverter-based resources (IBRs). The design is based on the idea of prioritizing the use of IBRs over conventional generator-based control in compensating for sudden and unpredicted changes in loads and generations, and thereby mitigate any undesired dynamics in the frequency or the voltage by exploiting their fast actuation time constants. A new sequential optimization problem, referred to as Area Prioritized Power Flow (APPF), is formulated to model this prioritization. It is shown that compared to conventional power flow APPF not only leads to a fairer balance between the dispatch of active and reactive power from the IBRs and the synchronous generators, but also limits the impact of any contingency from spreading out beyond its respective control area, thereby guaranteeing a better collective dynamic performance of the grid. This improvement, however, comes at the cost of adding an extra layer of communication needed for executing APPF in a hierarchical way. Results are validated using simulations of a 9-machine, 6-IBR, 33-bus, 3-area power system model, illustrating how APPF can mitigate a disturbance faster and more efficiently by prioritizing the use of local area-resources.