Researcher profile

M. Vicente Barreto Pinto

M. Vicente Barreto Pinto contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - Baseline
3works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Efficiency and time resolution of monolithic silicon pixel detectors in SiGe BiCMOS technology

A monolithic silicon pixel detector prototype has been produced in the SiGe BiCMOS SG13G2 130 nm node technology by IHP. The ASIC contains a matrix of hexagonal pixels with pitch of approximately 100 $μ$m. Three analog pixels were calibrated in laboratory with radioactive sources and tested in a 180 GeV/c pion beamline at the CERN SPS. A detection efficiency of $\left(99.9^{+0.1}_{-0.2}\right)$% was measured together with a time resolution of $(36.4 \pm 0.8)$ps at the highest preamplifier bias current working point of 150 $μ$A and at a sensor bias voltage of 160 V. The ASIC was also characterized at lower bias voltage and preamplifier current.

preprint2022arXiv

Pixel detector hybridisation with Anisotropic Conductive Films

Hybrid pixel detectors require a reliable and cost-effective interconnect technology adapted to the pitch and die sizes of the respective applications. During the ASIC and sensor R&D phase, and in general for small-scale applications, such interconnect technologies need to be suitable for the assembly of single-dies, typically available from Multi-Project-Wafer submissions. Within the CERN EP R&D programme and the AIDAinnova collaboration, innovative hybridisation concepts targeting vertex-detector applications at future colliders are under development. This contribution presents recent results of a newly developed in-house single-die interconnection process based on Anisotropic Conductive Film (ACF). The ACF interconnect technology replaces the solder bumps with conductive particles embedded in an adhesive film. The electro-mechanical connection between the sensor and the read-out chip is achieved via thermo-compression of the ACF using a flip-chip device bonder. A specific pad topology is required to enable the connection via conductive particles and create cavities into which excess epoxy can flow. This pixel-pad topology is achieved with an in-house Electroless Nickel Immersion Gold (ENIG) plating process that is also under development within the project. The ENIG and ACF processes are qualified with the Timepix3 ASIC and sensors, with 55 um pixel pitch and 14 um pad diameter. The ACF technology can also be used for ASIC-PCB/FPC integration, replacing wire bonding or large-pitch solder bumping techniques. This contribution introduces the ENIG plating and ACF processes and presents recent results on Timepix3 hybrid assemblies.

preprint2022arXiv

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons

The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1 cm$^2$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.