Source author record

M. V. Romalis

M. V. Romalis appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

17works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

17 published item(s)

preprint2021arXiv

Femtotesla direct magnetic gradiometer using a single multipass cell

We describe a direct gradiometer using optical pumping with opposite circular polarization in two $^{87}$Rb atomic ensembles within a single multipass cell. A far-detuned probe laser undergoes a near-zero paramagnetic Faraday rotation due to the intrinsic subtraction of two contributions exceeding 3.5 rad from the highly-polarized ensembles. We develop analysis methods for the direct gradiometer signal and measure a gradiometer sensitivity of $10.1$ fT/cm$\sqrt{\mathrm{Hz}}$. We also demonstrate that our multipass design, in addition to increasing the optical depth, provides a fundamental advantage due to the significantly reduced effect of atomic diffusion on the spin noise time-correlation, in excellent agreement with theoretical estimate.

preprint2021arXiv

Femtotesla nearly quantum-noise-limited pulsed gradiometer at Earth-scale fields

We describe a finite fields magnetic gradiometer using an intense pulsed laser to polarize a $^{87}$Rb atomic ensemble and a compact VCSEL probe laser to detect paramagnetic Faraday rotation in a single multipass cell. We report differential magnetic sensitivity of $14$ fT/Hz$^{1/2}$ over a broad dynamic range including Earth's field magnitude and common-mode rejection ratio higher than $10^4$. We also observe a nearly quantum-noise-limited behaviour of the gradiometer, by comparing the experimental standard deviation of the estimated frequency difference against the Cramér-Rao lower bound in the presence of white photon shot-noise, atomic spin noise and atomic diffusion.

preprint2020arXiv

Portable magnetometry for detection of biomagnetism in ambient environments

We present a method of optical magnetometry with parts-per-billion resolution that is able to detect biomagnetic signals generated from the human brain and heart in Earth's ambient environment. Our magnetically silent sensors measure the total magnetic field by detecting the free-precession frequency of highly spin-polarized alkali metal vapor. A first-order gradiometer is formed from two magnetometers that are separated by a 3 cm baseline. Our gradiometer operates from a laptop consuming 5 W over a USB port, enabled by state-of-the-art micro-fabricated alkali vapor cells, advanced thermal insulation, custom electronics, and laser packages within the sensor head. The gradiometer obtains a sensitivity of 16 fT/cm/Hz$^{1/2}$ outdoors, which we use to detect neuronal electrical currents and magnetic cardiography signals. Recording of neuronal magnetic fields is one of a few available methods for non-invasive functional brain imaging that usually requires extensive magnetic shielding and other infractructure. This work demonstrates the possibility of a dense array of portable biomagnetic sensors that are deployable in a variety of natural environments.

preprint2012arXiv

Sub-femtotesla scalar atomic magnetometer using multipass cells

Scalar atomic magnetometers have many attractive features but their sensitivity has been relatively poor. We describe a Rb scalar gradiometer using two multi-pass optical cells. We use a pump-probe measurement scheme to suppress spin-exchange relaxation and two probe pulses to find the spin precession zero crossing times with a resolution of 1 psec. We realize magnetic field sensitivity of 0.54 fT/Hz$^{1/2}$, which improves by an order of magnitude the best scalar magnetometer sensitivity and surpasses the quantum limit set by spin-exchange collisions for a scalar magnetometer with the same measurement volume operating in a continuous regime.

preprint2011arXiv

A new test of local Lorentz invariance using $^{21}$Ne-Rb-K comagnetometer

We develop a new comagnetometer using $^{21}$Ne atoms with nuclear spin $I=3/2$ and Rb atoms polarized by spin-exchange with K atoms to search for tensor interactions that violate local Lorentz invariance. We frequently reverse orientation of the experiment and search for signals at the first and second harmonics of the sidereal frequency. We constrain 4 of the 5 spatial Lorentz-violating coefficients $c^n_{jk}$ that parameterize anisotropy of the maximum attainable velocity of a neutron at a level of $10^{-29}$, improving previous limits by 2 to 4 orders of magnitude and placing the most stringent constrain on deviations from local Lorentz invariance.

preprint2011arXiv

Measurement of Linear Stark Interference in 199Hg

We present measurements of Stark interference in the 6$^1S_0$ $\rightarrow$ 6$^3P_1$ transition in $^{199}$Hg, a process whereby a static electric field $E$ mixes magnetic dipole and electric quadrupole couplings into an electric dipole transition, leading to $E$-linear energy shifts similar to those produced by a permanent atomic electric dipole moment (EDM). The measured interference amplitude, $a_{SI}$ = $(a_{M1} + a_{E2})$ = (5.8 $\pm$ 1.5)$\times 10^{-9}$ (kV/cm)$^{-1}$, agrees with relativistic, many-body predictions and confirms that earlier central-field estimates are a factor of 10 too large. More importantly, this study validates the capability of the $^{199}$Hg EDM search apparatus to resolve non-trivial, controlled, and sub-nHz Larmor frequency shifts with EDM-like characteristics.

preprint2011arXiv

Very large optical rotation generated by Rb vapor in a multi-pass cell

Paramagnetic Faraday rotation is a powerful technique for atom sensing widely used in quantum non-demolition measurements, fundamental symmetry tests, and other precision measurements. We demonstrate the use of a multi-pass optical cell for Faraday rotation spectroscopy and observe polarization rotation in excess of 100 radians from spin-polarized Rb vapor. Unlike optical cavities, multi-pass cells have a deterministic number of light passes and can be used to measure large optical rotations. We also observe a 10-fold suppression of transverse spin relaxation when Rb atoms are placed in a coherent superposition state immune to spin-exchange collisions.

preprint2010arXiv

High Bandwidth Atomic Magnetometery with Continuous Quantum Non-demolition Measurements

We describe an experimental study of spin-projection noise in a high sensitivity alkali-metal magnetometer. We demonstrate a four-fold improvement in the measurement bandwidth of the magnetometer using continuous quantum non-demolition (QND) measurements. Operating in the scalar mode with a measurement volume of 2 cm^3 we achieve magnetic field sensitivity of 22 fT/Hz^(1/2) and a bandwidth of 1.9 kHz with a spin polarization of only 1%. Our experimental arrangement is naturally back-action evading and can be used to realize sub-fT sensitivity with a highly polarized spin-squeezed atomic vapor.

preprint2010arXiv

Hybrid optical pumping of optically dense alkali-metal vapor without quenching gas

Optical pumping of an optically thick atomic vapor typically requires a quenching buffer gas, such as N$_{2}$, to prevent radiation trapping of unpolarized photons which would depolarize the atoms. We show that optical pumping of a trace contamination of Rb present in K metal results in a 4.5 times higher polarization of K than direct optical pumping of K in the absence of N$_{2}$. Such spin-exchange polarization transfer from optically-thin species is useful in a variety of areas, including spin-polarized nuclear scattering targets and electron beams, quantum-non-demolition spin measurements, and ultra-sensitive magnetometry.

preprint2010arXiv

Isotropic magnetometry with simultaneous excitation of orientation and alignment CPT resonances

Atomic magnetometers have very high absolute precision and sensitivity to magnetic fields but suffer from a fundamental problem: the vectorial or tensorial interaction of light with atoms leads to "dead zones", certain orientations of magnetic field where the magnetometer loses its sensitivity. We demonstrate a simple polarization modulation scheme that simultaneously creates coherent population trapping (CPT) in orientation and alignment, thereby eliminating dead zones. Using $^{87}$Rb in a 10 Torr buffer gas cell we measure narrow, high-contrast CPT transparency peaks in all orientations and also show absence of systematic effects associated with non-linear Zeeman splitting.

preprint2010arXiv

Limits on new long range nuclear spin-dependent forces set with a K-3He co-magnetometer

A magnetometer using spin-polarized K and $^3$He atoms occupying the same volume is used to search for anomalous nuclear spin-dependent forces generated by a separate $^3$He spin source. We measure changes in the $^3$He spin precession frequency with a resolution of 18 pHz and constrain anomalous spin forces between neutrons to be less than $2 \times 10^{-8}$ of their magnetic or less than $2\times 10^{-3}$ of their gravitational interactions on a length scale of 50 cm. We present new limits on neutron coupling to light pseudoscalar and vector particles, including torsion, and constraints on recently proposed models involving unparticles and spontaneous breaking of Lorentz symmetry.

preprint2010arXiv

New limit on Lorentz and CPT-violating neutron spin interactions

We performed a search for neutron spin coupling to a Lorentz and CPT-violating background field using a magnetometer with overlapping ensembles of K and $^3$He atoms. The co-magnetometer is mounted on a rotary platform for frequent reversal of its orientation. We measure sidereal oscillations in the signal to search for anomalous spin coupling of extra-solar origin. We determine the equatorial components of the background field interacting with the neutron spin to be $\widetilde{b}^n_X = (0.1 \pm 1.6) \times 10^{-33}$ GeV and $\widetilde{b}^n_Y = (2.5 \pm 1.6) \times 10^{-33}$ GeV, improving on the previous limit by a factor of 30. This measurement represents the highest energy resolution of any spin anisotropy experiment.

preprint2010arXiv

Stroboscopic back-action evasion in a dense alkali-metal vapor

We explore experimentally quantum non-demolition (QND) measurements of atomic spin in a hot potassium vapor in the presence of spin-exchange relaxation. We demonstrate a new technique for back-action evasion by stroboscopic modulation of the probe light. With this technique we study spin noise as a function of polarization for atoms with spin greater than 1/2 and obtain good agreement with a simple theoretical model. We point that in a system with fast spin-exchange, where the spin relaxation rate is changing with time, it is possible to improve the long-term sensitivity of atomic magnetometry by using QND measurements.

preprint2009arXiv

A Low-Noise High-Density Alkali Metal Scalar Magnetometer

We present an experimental and theoretical study of a scalar atomic magnetometer using an oscillating field-driven Zeeman resonance in a high-density optically-pumped potassium vapor. We describe an experimental implementation of an atomic gradiometer with a noise level below 10 fT/Hz^{1/2}, fractional field sensitivity below 10^{-9}/Hz^{1/2}, and an active measurement volume of about 1.5 cm^3. We show that the fundamental field sensitivity of a scalar magnetometer is determined by the rate of alkali-metal spin-exchange collisions even though the resonance linewidth can be made much smaller than the spin-exchange rate by pumping most atoms into a stretched spin state.

preprint2009arXiv

Ultra-high sensitivity magnetic field and magnetization measurements with an atomic magnetometer

We describe an ultra-sensitive atomic magnetometer using optically-pumped potassium atoms operating in spin-exchange relaxation free (SERF) regime. We demonstrate magnetic field sensitivity of 160 aT/Hz$^{1/2}$ in a gradiometer arrangement with a measurement volume of 0.45 cm$^3$ and energy resolution per unit time of $44 \hbar$. As an example of a new application enabled by such a magnetometer we describe measurements of weak remnant rock magnetization as a function of temperature with a sensitivity on the order of 10$^{-10}$ emu/cm$^3$/Hz$^{1/2}$ and temperatures up to 420$^\circ$C.

preprint2007arXiv

Spin-exchange relaxation free magnetometry with Cs vapor

We describe a Cs atomic magnetometer operating in the spin-exchange relaxation-free (SERF) regime. With a vapor cell temperature of $103^\circ\rm{C}$ we achieve intrinsic magnetic resonance widths $ΔB=17 {\rm μG}$ corresponding to an electron spin-relaxation rate of $300 {\rm s^{-1}}$ when the spin-exchange rate is $Γ_{SE}=14000 {\rm s^{-1}}$. We also observe an interesting narrowing effect due to diffusion. Signal-to-noise measurements yield a sensitivity of about $400\thinspace{\rm pG/\sqrt{Hz}}$. Based on photon shot noise, we project a sensitivity of $40 {\rm pG/\sqrt{Hz}}$. A theoretical optimization of the magnetometer indicates sensitivities on the order of $2 {\rm pG/\sqrt{Hz}}$ should be achievable in a $1 {\rm cm^3}$ volume. Because Cs has a higher saturated vapor pressure than other alkali metals, SERF magnetometers using Cs atoms are particularly attractive in applications requiring lower temperatures.

preprint2006arXiv

Optical Magnetometry

Some of the most sensitive methods of measuring magnetic fields utilize interactions of resonant light with atomic vapor. Recent developments in this vibrant field are improving magnetometers in many traditional areas such as measurement of geomagnetic anomalies and magnetic fields in space, and are opening the door to new ones, including, dynamical measurements of bio-magnetic fields, detection of nuclear magnetic resonance (NMR), magnetic-resonance imaging (MRI), inertial-rotation sensing, magnetic microscopy with cold atoms, and tests of fundamental symmetries of Nature.