Researcher profile

M. Tandecki

M. Tandecki contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2014arXiv

Offline trapping of $^{221}$Fr in a magneto-optical trap from implantation of an $^{225}$Ac ion beam

We demonstrate a new technique to prepare an offline source of francium for trapping in a magneto-optical trap. Implanting a radioactive beam of $^{225}$Ac, $t_{1/2} = 9.920(3)$ days, in a foil, allows use of the decay products, i.e.$^{221}$Fr, $t_{1/2} = 288.0(4)$ s. $^{221}$Fr is ejected from the foil by the $α$ decay of $^{225}$Ac. This technique is compatible with the online accumulation of a laser-cooled atomic francium sample for a series of planned parity non-conservation measurements at TRIUMF. We obtain a 34% release efficiency for $^{221}$Fr from the recoil source based on particle detector measurements. We find that laser cooling operation with the source is $8^{+10}_{-5}$ times less efficient than from a mass-separated ion beam of $^{221}$Fr in the current geometry. While the flux of this source is two to three orders of magnitude lower than typical francium beams from ISOL facilities, the source provides a longer-term supply of francium for offline studies.

preprint2013arXiv

Commissioning of the Francium Trapping Facility at TRIUMF

We report on the successful commissioning of the Francium Trapping Facility at TRIUMF. Large laser-cooled samples of francium are produced from a francium ion beam delivered by the ISAC radioactive ion beam facility. The ion beam is neutralized on an yttrium foil, which is subsequently heated to transfer the atoms into the magneto-optical trapping region. We have successfully trapped $^{207}$Fr, $^{209}$Fr and $^{221}$Fr, with a maximum of $2.5 \times 10^5$ $^{209}$Fr atoms. The neutral cold atoms will be used in studies of the weak interaction through measurements of atomic parity non-conservation.

preprint2011arXiv

Hyperfine Field and Hyperfine Anomalies of Copper Impurities in Iron

A new value for the hyperfine magnetic field of copper impurities in iron is obtained by combining resonance frequencies from experiments involving β-NMR on oriented nuclei on 59-Cu, 69-Cu, and 71-Cu with magnetic moment values from collinear laser spectroscopy measurements on these isotopes. The resulting value, i.e., Bhf(CuFe) = -21.794(10) T, is in agreement with the value adopted until now but is an order of magnitude more precise. It is consistent with predictions from ab initio calculations. Comparing the hyperfine field values obtained for the individual isotopes, the hyperfine anomalies in Fe were determined to be 59Δ69=0.15(9)% and 71Δ69=0.07(11)%.

preprint2010arXiv

First detection and energy measurement of recoil ions following beta decay in a Penning trap with the WITCH experiment

The WITCH experiment (Weak Interaction Trap for CHarged particles) will search for exotic interactions by investigating the beta-neutrino angular correlation via the measurement of the recoil energy spectrum after beta decay. As a first step the recoil ions from the beta-minus decay of 124In stored in a Penning trap have been detected. The evidence for the detection of recoil ions is shown and the properties of the ion cloud that forms the radioactive source for the experiment in the Penning trap are presented.

preprint2010arXiv

Precision measurements of the $^{60}$Co $β$-asymmetry parameter in search for tensor currents in weak interactions

The $β$-asymmetry parameter $\widetilde{A}$ for the Gamow-Teller decay of $^{60}$Co was measured by polarizing the radioactive nuclei with the brute force low-temperature nuclear-orientation method. The $^{60}$Co activity was cooled down to milliKelvin temperatures in a $^3$He-$^4$He dilution refrigerator in an external 13 T magnetic field. The $β$ particles were observed by a 500 $μm$ thick Si PIN diode operating at a temperature of about 10 K in a magnetic field of 0.6 T. Extensive GEANT4 Monte-Carlo simulations were performed to gain control over the systematic effects. Our result, $\widetilde{A} = -1.014(12)_{stat}(16)_{syst}$, is in agreement with the Standard-Model value of $-0.987(9)$, which includes recoil-order corrections that were addressed for the first time for this isotope. Further, it enables limits to be placed on possible tensor-type charged weak currents as well as other physics beyond the Standard Model.

preprint2010arXiv

The half-life of $^{221}$Fr in Si and Au at 4K and at mK temperatures

The half-life of the $α$ decaying nucleus $^{221}$Fr was determined in different environments, i.e. embedded in Si at 4 K, and embedded in Au at 4 K and about 20 mK. No differences in half-life for these different conditions were observed within 0.1%. Furthermore, we quote a new value for the absolute half-life of $^{221}$Fr of t$_{1/2}$ = 286.1(10) s, which is of comparable precision to the most precise value available in literature.

preprint2009arXiv

A GEANT4 Monte-Carlo Simulation Code for precision beta spectroscopy

The measurement of the beta asymmetry parameter in nuclear beta decay is a potentially very sensitive tool to search for non V-A components in the charge-changing weak interaction. To reach the required precision (percent level) all effects that modify the emission pattern of the beta radiation, i.e. the geometry of the setup, the effect of the magnetic field on the trajectories of beta particles as well as (back)scattering in the source, on the sample holder and on the detector, have to be correctly taken into account in the analysis of the data. A thorough study of these effects and a new method based on detailed GEANT4 Monte-Carlo simulations that was developed for this purpose is presented here. The code was developed for beta asymmetry measurements by means of the Low Temperature Nuclear Orientation (LTNO) method, but can in principle be generalized to other experimental setups using other polarization techniques.