Source author record

M. Steidl

M. Steidl appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

18works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

18 published item(s)

preprint2022arXiv

GPU-based optical simulation of the DARWIN detector

Understanding propagation of scintillation light is critical for maximizing the discovery potential of next-generation liquid xenon detectors that use dual-phase time projection chamber technology. This work describes a detailed optical simulation of the DARWIN detector implemented using Chroma, a GPU-based photon tracking framework. To evaluate the framework and to explore ways of maximizing efficiency and minimizing the time of light collection, we simulate several variations of the conventional detector design. Results of these selected studies are presented. More generally, we conclude that the approach used in this work allows one to investigate alternative designs faster and in more detail than using conventional Geant4 optical simulations, making it an attractive tool to guide the development of the ultimate liquid xenon observatory.

preprint2022arXiv

Improved eV-scale Sterile-Neutrino Constraints from the Second KATRIN Measurement Campaign

We present the results of the light sterile neutrino search from the second KATRIN measurement campaign in 2019. Approaching nominal activity, $3.76 \times 10^6$ tritium $β$-electrons are analyzed in an energy window extending down to $40\,$eV below the tritium endpoint at $E_0 = 18.57\,$keV. We consider the $3ν+1$ framework with three active and one sterile neutrino flavor. The analysis is sensitive to a fourth mass eigenstate $m_4^2\lesssim1600\,$eV$^2$ and active-to-sterile mixing $|U_{e4}|^2 \gtrsim 6 \times 10^{-3}$. As no sterile-neutrino signal was observed, we provide improved exclusion contours on $m_4^2$ and $|U_{e4}|^2$ at $95\,$% C.L. Our results supersede the limits from the Mainz and Troitsk experiments. Furthermore, we are able to exclude the large $Δm_{41}^2$ solutions of the reactor antineutrino and gallium anomalies to a great extent. The latter has recently been reaffirmed by the BEST collaboration and could be explained by a sterile neutrino with large mixing. While the remaining solutions at small $Δm_{41}^2$ are mostly excluded by short-baseline reactor experiments, KATRIN is the only ongoing laboratory experiment to be sensitive to relevant solutions at large $Δm_{41}^2$ through a robust spectral shape analysis.

preprint2022arXiv

New Constraint on the Local Relic Neutrino Background Overdensity with the First KATRIN Data Runs

We report on the direct cosmic relic neutrino background search from the first two science runs of the KATRIN experiment in 2019. Beta-decay electrons from a high-purity molecular tritium gas source are analyzed by a high-resolution MAC-E filter around the kinematic endpoint at 18.57 keV. The analysis is sensitive to a local relic neutrino overdensity of 9.7e10 (1.1e11) at a 90% (95%) confidence level. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint accounting for relic neutrino captures in the Tritium source reveals no significant overdensity. This work improves the results obtained by the previous kinematic neutrino mass experiments at Los Alamos and Troitsk. We furthermore update the projected final sensitivity of the KATRIN experiment to <1e10 at 90% confidence level, by relying on updated operational conditions.

preprint2022arXiv

Search for keV-scale Sterile Neutrinos with first KATRIN Data

In this work we present a keV-scale sterile-neutrino search with the first tritium data of the KATRIN experiment, acquired in the commissioning run in 2018. KATRIN performs a spectroscopic measurement of the tritium $β$-decay spectrum with the main goal of directly determining the effective electron anti-neutrino mass. During this commissioning phase a lower tritium activity facilitated the search for sterile neutrinos with a mass of up to $1.6\, \mathrm{keV}$. We do not find a signal and set an exclusion limit on the sterile-to-active mixing amplitude of down to $\sin^2θ< 5\cdot10^{-4}$ ($95\,\%$ C.L.), improving current laboratory-based bounds in the sterile-neutrino mass range between 0.1 and $1.0\, \mathrm{keV}$.

preprint2021arXiv

Forward Beam Monitor for the KATRIN experiment

The \textit{KArlsruhe TRItium Neutrino} (KATRIN) experiment aims to measure the neutrino mass with a sensitivity of \SI{0.2}{\electronvolt} (\SI{90}{\percent} CL). This will be achieved by a precision measurement of the endpoint region of the $\upbeta$-electron spectrum of tritium decay. The $\upbeta$-electrons are produced in the \textit{Windowless Gaseous Tritium Source} (WGTS) and guided magnetically through the beamline. In order to accurately extract the neutrino mass the source activity is required to be stable and known to a high precision. The WGTS therefore undergoes constant extensive monitoring from several measurement systems. The \textit{Forward Beam Monitor} (FBM) is one such monitoring system. The FBM system comprises a complex mechanical setup capable of inserting a detector board into the KATRIN beamline with a positioning precision of better than \SI{0.3}{\milli\metre}. The electron flux density at that position is on the order of \SI{e6}{\per\second\per\milli\metre\squared}. The detector board contains two silicon detector chips of \pin diode type which can measure the $\upbeta$-electron flux from the source with a precision of \SI{0.1}{\percent} within \SI{60}{\second} with an energy resolution of FWHM $=$ \SI{2}{\kilo\electronvolt}. The unique challenge in developing the FBM arise from its designated operating environment inside the Cryogenic Pumping Section which is a potentially tritium contaminated ultra-high vacuum chamber at cryogenic temperatures in the presence of a \SI{1}{\tesla} strong magnetic field. Each of theses parameters do strongly limit the choice of possible materials which e.g. caused difficulties in detector noise reduction, heat dissipation and lubrication. In order to completely remove the FBM from the beam tube a \SI{2}{\meter} long traveling distance into the beamline is needed demanding a robust as well as highly precise moving mechanism.

preprint2020arXiv

Bound on 3+1 active-sterile neutrino mixing from the first four-week science run of KATRIN

We report on the light sterile neutrino search from the first four-week science run of the KATRIN experiment in~2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are analyzed by a high-resolution MAC-E filter down to 40 eV below the endpoint at 18.57 keV. We consider the framework with three active neutrinos and one sterile neutrino of mass $m_{4}$. The analysis is sensitive to a fourth mass state $m^2_{4} \lesssim$ 1000 eV$^2$ and to active-to-sterile neutrino mixing down to $|U_{e4}|^2 \gtrsim 2\cdot10^{-2}$. No significant spectral distortion is observed and exclusion bounds on the sterile mass and mixing are reported. These new limits supersede the Mainz results and improve the Troitsk bound for $m^2_{4} <$ 30 eV$^2$. The reactor and gallium anomalies are constrained for $ 100 < Δ{m}^2_{41} < 1000$ eV$^2$.

preprint2020arXiv

Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of $^{136}$Xe

The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of $^{136}$Xe. Out of its 50$\,$t total natural xenon inventory, 40$\,$t will be the active target of a time projection chamber which thus contains about 3.6 t of $^{136}$Xe. Here, we show that its projected half-life sensitivity is $2.4\times10^{27}\,$yr, using a fiducial volume of 5t of natural xenon and 10$\,$yr of operation with a background rate of less than 0.2$~$events/(t$\cdot$yr) in the energy region of interest. This sensitivity is based on a detailed Monte Carlo simulation study of the background and event topologies in the large, homogeneous target. DARWIN will be comparable in its science reach to dedicated double beta decay experiments using xenon enriched in $^{136}$Xe.

preprint2020arXiv

Suppression of Penning discharges between the KATRIN spectrometers

The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)neutrino mass with a sensitivity of $0.2\textrm{ eV/c}^2$ (90$\%$ C.L.) by precisely measuring the endpoint region of the tritium $β$-decay spectrum. It uses a tandem of electrostatic spectrometers working as MAC-E (magnetic adiabatic collimation combined with an electrostatic) filters. In the space between the pre-spectrometer and the main spectrometer, an unavoidable Penning trap is created when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create additional background electrons and endanger the spectrometer and detector section downstream. To counteract this problem, "electron catchers" were installed in the beamline inside the magnet bore between the two spectrometers. These catchers can be moved across the magnetic-flux tube and intercept on a sub-ms time scale the stored electrons along their magnetron motion paths. In this paper, we report on the design and the successful commissioning of the electron catchers and present results on their efficiency in reducing the experimental background.

preprint2019arXiv

First operation of the KATRIN experiment with tritium

The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay, provide a largely model-independent probe to the neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to directly measure the effective electron antineutrino mass with a sensitivity of 0.2 eV 90% CL. In this work we report on the first operation of KATRIN with tritium which took place in 2018. During this commissioning phase of the tritium circulation system, excellent agreement of the theoretical prediction with the recorded spectra was found and stable conditions over a time period of 13 days could be established. These results are an essential prerequisite for the subsequent neutrino mass measurements with KATRIN in 2019.

preprint2019arXiv

High-resolution spectroscopy of gaseous $^\mathrm{83m}$Kr conversion electrons with the KATRIN experiment

In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstrates the functionalities of the full KATRIN beamline. The KATRIN main spectrometer's excellent energy resolution of ~ 1 eV made it possible to determine the narrow K-32 and L$_3$-32 conversion electron line widths with an unprecedented precision of ~ 1 %.

preprint2016arXiv

Commissioning of the vacuum system of the KATRIN Main Spectrometer

The KATRIN experiment will probe the neutrino mass by measuring the beta-electron energy spectrum near the endpoint of tritium beta-decay. An integral energy analysis will be performed by an electro-static spectrometer (Main Spectrometer), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m^3, and a complex inner electrode system with about 120000 individual parts. The strong magnetic field that guides the beta-electrons is provided by super-conducting solenoids at both ends of the spectrometer. Its influence on turbo-molecular pumps and vacuum gauges had to be considered. A system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter strips has been deployed and was tested during the commissioning of the spectrometer. In this paper the configuration, the commissioning with bake-out at 300°C, and the performance of this system are presented in detail. The vacuum system has to maintain a pressure in the 10^{-11} mbar range. It is demonstrated that the performance of the system is already close to these stringent functional requirements for the KATRIN experiment, which will start at the end of 2016.

preprint2015arXiv

Focal-plane detector system for the KATRIN experiment

The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electrons selected by the KATRIN main spectrometer. We describe the system and summarize its performance after its final installation.

preprint2015arXiv

Wavelet Approach to Search for Sterile Neutrinos in Tritium $β$-Decay Spectra

Sterile neutrinos in the mass range of a few keV are candidates for both cold and warm dark matter. An ad-mixture of a heavy neutrino mass eigenstate to the electron neutrino would result in a minuscule distortion - a 'kink' - in a $β$-decay spectrum. In this paper we show that a wavelet transform is a very powerful shape analysis method to detect this signature. For a tritium source strength, similar to what is expected from the KATRIN experiment, a statistical sensitivity to active-to-sterile neutrino mixing down to $\sin^2 θ= 10^{-6}$ ($90\%$ CL) can be obtained after 3 years of measurement time. It is demonstrated that the wavelet approach is largely insensitive to systematic effects that result in smooth spectral modifications. To make full use of this analysis technique a high resolution measurement (FWHM of $\sim100$~eV) of the tritium $β$-decay spectrum is required.

preprint2014arXiv

Sensitivity of Next-Generation Tritium Beta-Decay Experiments for keV-Scale Sterile Neutrinos

We investigate the sensitivity of tritium $β$-decay experiments for keV-scale sterile neutrinos. Relic sterile neutrinos in the keV mass range can contribute both to the cold and warm dark matter content of the universe. This work shows that a large-scale tritium beta-decay experiment, similar to the KATRIN experiment that is under construction, can reach a statistical sensitivity of the active-sterile neutrino mixing of $\sin^2θ\sim 10^{-8}$. The effect of uncertainties in the known theoretical corrections to the tritium $β$-decay spectrum were investigated, and found not to affect the sensitivity significantly. It is demonstrated that controlling uncorrelated systematic effects will be one of the main challenges in such an experiment.

preprint2013arXiv

Dead layer on silicon p-i-n diode charged-particle detectors

Semiconductor detectors in general have a dead layer at their surfaces that is either a result of natural or induced passivation, or is formed during the process of making a contact. Charged particles passing through this region produce ionization that is incompletely collected and recorded, which leads to departures from the ideal in both energy deposition and resolution. The silicon \textit{p-i-n} diode used in the KATRIN neutrino-mass experiment has such a dead layer. We have constructed a detailed Monte Carlo model for the passage of electrons from vacuum into a silicon detector, and compared the measured energy spectra to the predicted ones for a range of energies from 12 to 20 keV. The comparison provides experimental evidence that a substantial fraction of the ionization produced in the "dead" layer evidently escapes by diffusion, with 46% being collected in the depletion zone and the balance being neutralized at the contact or by bulk recombination. The most elementary model of a thinner dead layer from which no charge is collected is strongly disfavored.

preprint2012arXiv

Monitoring of the operating parameters of the KATRIN Windowless Gaseous Tritium Source

The Karlsruhe Tritium Neutrino (KATRIN) experiment will measure the absolute mass scale of neutrinos with a sensitivity of $\m_ν$ = 200 meV/c$^2$ by high-precision spectroscopy close to the tritium beta-decay endpoint at 18.6 keV. Its Windowless Gaseous Tritium Source (WGTS) is a beta-decay source of high intensity ($10^{11}$/s) and stability, where high-purity molecular tritium at 30 K is circulated in a closed loop with a yearly throughput of 10 kg. To limit systematic effects the column density of the source has to be stabilised at the 0.1% level. This requires extensive sensor instrumentation and dedicated control and monitoring systems for parameters such as the beam tube temperature, injection pressure, gas composition and others. Here we give an overview of these systems including a dedicated Laser-Raman system as well as several beta-decay activity monitors. We also report on results of the WGTS demonstrator and other large-scale test experiments giving proof-of-principle that all parameters relevant to the systematics can be controlled and monitored on the 0.1% level or better. As a result of these works, the WGTS systematics can be controlled within stringent margins, enabling the KATRIN experiment to explore the neutrino mass scale with the design sensitivity.

preprint2012arXiv

The KATRIN Pre-Spectrometer at reduced Filter Energy

The KArlsruhe TRItium Neutrino experiment, KATRIN, will determine the mass of the electron neutrino with a sensitivity of 0.2 eV (90% C.L.) via a measurement of the beta-spectrum of gaseous tritium near its endpoint of E_0 =18.57 keV. An ultra-low background of about b = 10 mHz is among the requirements to reach this sensitivity. In the KATRIN main beam-line two spectrometers of MAC-E filter type are used in a tandem configuration. This setup, however, produces a Penning trap which could lead to increased background. We have performed test measurements showing that the filter energy of the pre-spectrometer can be reduced by several keV in order to diminish this trap. These measurements were analyzed with the help of a complex computer simulation, modeling multiple electron reflections both from the detector and the photoelectric electron source used in our test setup.

preprint1998arXiv

Measurement of the energy spectrum of ν_e from muon decay and implications for the Lorentz structure of the weak interaction

The KARMEN experiment uses the reaction 12C(ν_e,e-)12N to measure the energy distribution of ν_e emitted in muon decay at rest. The ν_e analog ω_l of the famous Michel parameter ρhas been derived from a maximum-likelihood analysis of events near the kinematic end point, E_max. The result, ω_l = (2.7^{+3.8}_{-3.3}\pm 3.1) * 10^{-2}, is in good agreement with the standard model prediction ω_l= 0. We deduce a 90% confidence upper limit of ω_l <= 0.113, which corresponds to a limit of |g^S_RL + 2 g^T_RL| <= 0.78 on the interference term between scalar and tensor coupling constants.