Source author record

M. Silarski

M. Silarski appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

82works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

82 published item(s)

preprint2022arXiv

Precision tests of Quantum Mechanics and CPT symmetry with entangled neutral kaons at KLOE

The quantum interference between the decays of entangled neutral kaons is studied in the process $ϕ\rightarrow K_S K_L \rightarrowπ^+π^-π^+π^-$, which exhibits the characteristic Einstein--Podolsky--Rosen correlations that prevent both kaons to decay into $π^+π^-$ at the same time. This constitutes a very powerful tool for testing at the utmost precision the quantum coherence of the entangled kaon pair state, and to search for tiny decoherence and CPT violation effects, which may be justified in a quantum gravity framework. The analysed data sample was collected with the KLOE detector at DA$Φ$NE, the Frascati $ϕ$-factory, and corresponds to an integrated luminosity of about 1.7 fb$^{-1}$, i.e. to about $1.7 \times 10^9$ $ϕ\rightarrow K_S K_L$ decays produced. From the fit of the observed $Δt$ distribution, being $Δt$ the difference of the kaon decay times, the decoherence and CPT violation parameters of various phenomenological models are measured with a largely improved accuracy with respect to previous analyses. The results are consistent with no deviation from quantum mechanics and CPT symmetry, while for some parameters the precision reaches the interesting level at which -- in the most optimistic scenarios -- quantum gravity effects might show up. They provide the most stringent limits up to date on the considered models.

preprint2022arXiv

Studies of the linearity and stability of Silicon Drift Detectors for kaonic atoms X-ray spectroscopy

The SIDDHARTA-2 experiment at the DA$Φ$NE collider aims to perform precision measurements of kaonic atoms X-ray spectroscopy for the investigation of the antikaon-nucleon strong interaction. To achieve this goal, novel large-area Silicon Drift Detectors (SDDs) have been developed. These devices have special geometry, field configuration and readout electronics that ensure excellent performance in terms of linearity and stability. The paper presents preliminary results for the linearity determination and stability monitoring of the SDDs system during the measurement of kaonic deuterium carried out in the summer of 2022.

preprint2021arXiv

Upper limit on the $η\toπ^{+}π^{-}$ branching fraction with the KLOE experiment

Based on an integrated luminosity of 1.61 fb$^{-1}$ $e^+e^-$ collision data collected with the KLOE detector at DA$Φ$NE, the Frascati $ϕ$-factory, a search for the $P$- and $CP$-violating decay $η\toπ^{+}π^{-}$ has been performed. Radiative $ϕ\toηγ$ decay is exploited to access the $η$ mesons. No signal is observed in the $π^{+}π^{-}$ invariant mass spectrum, and the upper limit on the branching fraction at 90\% confidence level is determined to be ${\mathcal B}(η\toπ^{+}π^{-})<4.9\times10^{-6}$, which is approximately three times smaller than the previous KLOE result. From the combination of these two measurements we get ${\mathcal B}(η\toπ^{+}π^{-}) < 4.4\times10^{-6}$ at 90\% confidence level.

preprint2020arXiv

Hit-time and hit-position reconstruction in strips of plastic scintillators using multi-threshold readouts

In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recent development of the positron emission tomography scanners based on plastic scintillators. The proposed method constitutes a new way of signal processing in Multi-Voltage-Technique. It is based on the determination of the degree of similarity between the registered signals and the synchronized model signals stored in a library. The library was established for a set of well defined hit-positions along the length of the scintillator. The Mahalanobis distance was used as a measure of similarity between the two compared signals. The method was validated on the experimental data measured using two-strips J-PET prototype with dimensions of 5x9x300 mm$^3$. The obtained Time-of-Flight (TOF) and spatial resolutions amount to 325~ps (FWHM) and 25~mm (FWHM), respectively. The TOF resolution was also compared to the results of an analogous study done using Linear Fitting method. The best TOF resolution was obtained with this method at four pre-defined threshold levels which was comparable to the resolution achieved from the Mahalanobis distance at two pre-defined threshold levels. Although the algorithm of Linear Fitting method is much simpler to apply than the Mahalanobis method, the application of the Mahalanobis distance requires a lower number of applied threshold levels and, hence, decreases the costs of electronics used in PET scanner.

preprint2020arXiv

Measurement of the branching fraction for the decay $K_S \to πμν$ with the KLOE detector

Based on a sample of 300 million $K_S$ mesons produced in $ϕ\to K_L K_S$ decays recorded by the KLOE experiment at the DA$Φ$NE $e^+e^-$ collider we have measured the branching fraction for the decay $K_S \to πμν$. The $K_S$ mesons are identified by the interaction of $K_L$ mesons in the detector. The $K_S \to πμν$ decays are selected by a boosted decision tree built with kinematic variables and by a time-of-flight measurement. Signal efficiencies are evaluated with data control samples of $K_L \to πμν$ decays. A fit to the reconstructed muon mass distribution finds $7223 \pm 180$ signal events. Normalising to the $K_S \to π^+ π^-$ decay events the result for the branching fraction is $\mathcal{B}(K_S \to πμν) = (4.56 \pm 0.11_{\rm stat} \pm 0.17_{\rm syst})\times10^{-4}$.

preprint2020arXiv

Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view

Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with the inner diameter of 360 mm and the axial field-of-view of 300 mm. Promising perspectives for a low-cost construction of a total-body PET scanner are opened due to an axial arrangement of strips of plastic scintillators, wchich have a small light attenuation, superior timing properties, and the possibility of cost-effective increase of the axial field-of-view. The presented prototype comprises dedicated solely digital front-end electronic circuits and a triggerless data acquisition system which required development of new calibration methods including time, thresholds and gain synchronization. The system and elaborated calibration methods including first results of the 24-module J-PET prototype are presented and discussed. The achieved coincidence resolving time equals to CRT = 490 $\pm$ 9 ps. This value can be translated to the position reconstruction accuracy $σ(Δl) =$ 18 mm which is fairly position-independent.

preprint2018arXiv

Status and Prospects of Discrete Symmetries Tests in Positronium Decays with the J-PET Detector

Positronium is a unique laboratory to study fundamental symmetries in the Standard Model, reflection in space ($\mathcal{P}$), reversal in time ($\mathcal{T}$), charge conjugation ($\mathcal{C}$) and their combinations. The experimental limits on the $\mathcal{C}$, $\mathcal{CP}$ and $\mathcal{CPT}$ symmetries violation in the decays of positronium are still several orders of magnitude higher than the expectations. The newly constructed Jagiellonian Positron Emission Tomograph (J-PET) was optimized for the registration of photons from the electron-positron annihilations. It enables tests of discrete symmetries in decays of positronium atoms via the determination of the expectation values of the discrete-symmetries-odd operators. In this article we present the capabilities of the J-PET detector in improving the current precision of discrete symmetries tests and report on the progress of analysis data from the first data-taking runs.

preprint2016arXiv

A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators

We present a study of the application of the Jagiellonian Positron Emission Tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PET is the first positron emission tomography scanner based on organic scintillators in contrast to all current PET scanners based on inorganic crystals. Monte Carlo simulations show that the J-PET as an axially symmetric and high acceptance scanner can be used as a multi-purpose detector well suited to pursue research including e.g. tests of discrete symmetries in decays of ortho-positronium in addition to the medical imaging. The gamma quanta originating from o-Ps decay interact in the plastic scintillators predominantly via the Compton effect, making the direct measurement of their energy impossible. Nevertheless, it is shown in this paper that the J-PET scanner will enable studies of the o-Ps$\to3γ$ decays with angular and energy resolution equal to $σ(θ) \approx 0.4^{\circ}$ and $σ(E) \approx 4.1$ keV, respectively. An order of magnitude shorter decay time of signals from plastic scintillators with respect to the inorganic crystals results not only in better timing properties crucial for the reduction of physical and instrumental background, but also suppresses significantly the pileups, thus enabling compensation of the lower efficiency of the plastic scintillators by performing measurements with higher positron source activities.

preprint2016arXiv

Limit on the production of a new vector boson in $\mathrm{e^+ e^-}\rightarrow {\rm U}γ$, U$\rightarrow π^+π^-$ with the KLOE experiment

The recent interest in a light gauge boson in the framework of an extra U(1) symmetry motivates searches in the mass range below 1 GeV. We present a search for such a particle, the dark photon, in ${\rm e^+ e^-}\rightarrow {\rm U}γ$, U$\rightarrow π^+π^-$ based on 28 million $\mathrm{e^+ e^-} \rightarrow π^+ π^-γ$ events collected at DA$Φ$NE by the KLOE experiment. The $π^+ π^-$ production by initial-state radiation compensates for a loss of sensitivity of previous KLOE ${\rm U} \rightarrow \mathrm{e^+ e^-}$, $μ^+μ^-$ searches due to the small branching ratios in the $ρ-ω$ resonance region. We found no evidence for a signal and set a limit at 90\% CL on the mixing strength between the photon and the dark photon, $\varepsilon^2$, in the U mass range between $527$ and $987$~MeV. Above 700 MeV this new limit is more stringent than previous ones.

preprint2016arXiv

Measurement of the $ϕ\to π^0 e^+e^-$ transition form factor with the KLOE detector

A measurement of the vector to pseudoscalar conversion decay $ϕ\to π^0 e^+e^-$ with the KLOE experiment is presented. A sample of $\sim 9500$ signal events was selected from a data set of 1.7 fb$^{-1}$ of $e^+e^-$ collisions at $\sqrt{s} \sim m_ϕ$ collected at the DA$Φ$NE $e^+e^-$ collider. These events were used to obtain the first measurement of the transition form factor $| F_{ϕπ^0}(q^2) |$ and a new measurement of the branching ratio of the decay: $\rm{BR}\,(ϕ\to π^0 e^+e^-) = (\,1.35 \pm 0.05^{\,\,+0.05}_{\,\,-0.10}\,) \times 10 ^{-5}$. The result improves significantly on previous measurements and is in agreement with theoretical predictions.

preprint2016arXiv

Overview of the software architecture and data flow for the J-PET tomography device

Modern TOF-PET scanner systems require high-speed computing resources for efficient data processing, monitoring and image reconstruction. In this article we present the data flow and software architecture for the novel TOF-PET scanner developed by the J-PET collaboration. We discuss the data acquisition system, reconstruction framework and image reconstruction software. Also, the concept of computing outside hospitals in the remote centers such as Świerk Computing Centre in Poland is presented.

preprint2016arXiv

Potential of the J-PET detector for studies of discrete symmetries in decays of positronium atom - a purely leptonic system

The Jagiellonian Positron Emission Tomograph (J-PET) was constructed as a prototype of the cost-effective scanner for the simultaneous metabolic imaging of the whole human body. Being optimized for the detection of photons from the electron-positron annihilation with high time- and high angular-resolution, it constitutes a multi-purpose detector providing new opportunities for studying the decays of positronium atoms. Positronium is the lightest purely leptonic object decaying into photons. As an atom bound by a central potential it is a parity eigenstate, and as an atom built out of an electron and an anti-electron it is an eigenstate of the charge conjugation operator. Therefore, the positronium is a unique laboratory to study discrete symmetries whose precision is limited in principle by the effects due to the weak interactions expected at the level of (~10$^{-14}$) and photon-photon interactions expected at the level of (~10$^{-9}$). The J-PET detector enables to perform tests of discrete symmetries in the leptonic sector via the determination of the expectation values of the discrete-symmetries-odd operators, which may be constructed from the spin of ortho-positronium atom and the momenta and polarization vectors of photons originating from its annihilation. In this article we present the potential of the J-PET detector to test the C, CP, T and CPT symmetries in the decays of positronium atoms.

preprint2016arXiv

Precision measurement of the $η\toπ^+π^-π^0$ Dalitz plot distribution with the KLOE detector

Using $1.6$ fb$^{-1}$ of $e^+ e^-\toϕ\toηγ$ data collected with the KLOE detector at DA$Φ$NE, the Dalitz plot distribution for the $η\to π^+ π^- π^0$ decay is studied with the world's largest sample of $\sim 4.7 \cdot 10^6$ events. The Dalitz plot density is parametrized as a polynomial expansion up to cubic terms in the normalized dimensionless variables $X$ and $Y$. The experiment is sensitive to all charge conjugation conserving terms of the expansion, including a $gX^2Y$ term. The statistical uncertainty of all parameters is improved by a factor two with respect to earlier measurements.

preprint2016arXiv

The KLOE-2 experiment at DAFNE

The KLOE-2 experiment at the INFN Laboratori Nazionali di Frascati (LNF) is currently taking data at the upgraded $e^{+}e^{-}$ DAFNE collider. Present Run II follows a~development phase to assess the feasibility of a long term acquisition program, Run I, which successfully ended in July 2015 with 1 fb$^{-1}$ integrated luminosity collected in less than eight months. KLOE-2 represents the continuation of the KLOE experiment with a new physics program. The KLOE detector has undergone several upgrades including state-of-the-art cylindrical GEM Inner Tracker, electron-positron taggers for the $γγ$-physics studies and new calorimeters around the interaction point. In this article we briefly present the overview of the KLOE-2 experiment including the present status and achievements together with the physics plans.

preprint2016arXiv

Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph

Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved resolution is almost by a factor of two better with respect to the current TOF-PET detectors and it can still be improved since, as it is shown in this article, the intrinsic limit of time resolution for the determination of time of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much lower. As the major point of the article, a method allowing to record timestamps of several photons, at two ends of the scintillator strip, by means of matrix of silicon photomultipliers (SiPM) is introduced. As a result of simulations, conducted with the number of SiPM varying from 4 to 42, it is shown that the improvement of timing resolution saturates with the growing number of photomultipliers, and that the 2 x 5 configuration at two ends allowing to read twenty timestamps, constitutes an optimal solution. The conducted simulations accounted for the emission time distribution, photon transport and absorption inside the scintillator, as well as quantum efficiency and transit time spread of photosensors, and were checked based on the experimental results. Application of the 2 x 5 matrix of SiPM allows for achieving the coincidence resolving time in positron emission tomography of $\approx$ 0.170 ns for 15 cm axial field-of-view (AFOV) and $\approx$ 0.365 ns for 100 cm AFOV. The results open perspectives for construction of a cost-effective TOF-PET scanner with significantly better TOF resolution and larger AFOV with respect to the current TOF-PET modalities.

preprint2016arXiv

Trilateration-based reconstruction of ortho-positronium decays into three photons with the J-PET detector

This work reports on a new reconstruction algorithm allowing to reconstruct the decays of ortho-positronium atoms into three photons using the places and times of photons recorded in the detector. The method is based on trilateration and allows for a simultaneous reconstruction of both location and time of the decay. Results of resolution tests of the new reconstruction in the J-PET detector based on Monte Carlo simulations are presented, which yield a spatial resolution at the level of 2 cm (FWHM) for X and Y and at the level of 1 cm (FWHM) for Z available with the present resolution of J-PET after application of a kinematic fit. Prospects of employment of this method for studying angular correlations of photons in decays of polarized ortho-positronia for the needs of tests of CP and CPT discrete symmetries are also discussed. The new reconstruction method allows for discrimination of background from random three-photon coincidences as well as for application of a novel method for determination of the linear polarization of ortho-positronium atoms, which is also introduced in this work.

preprint2015arXiv

A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signals

A novel method of hit time and hit position reconstruction in scintillator detectors is described. The method is based on comparison of detector signals with results stored in a library of synchronized model signals registered for a set of well-defined positions of scintillation points. The hit position is reconstructed as the one corresponding to the signal from the library which is most similar to the measurement signal. The time of the interaction is determined as a relative time between the measured signal and the most similar one in the library. A degree of similarity of measured and model signals is defined as the distance between points representing the measurement- and model-signal in the multi-dimensional measurement space. Novelty of the method lies also in the proposed way of synchronization of model signals enabling direct determination of the difference between time-of-flights (TOF) of annihilation quanta from the annihilation point to the detectors. The introduced method was validated using experimental data obtained by means of the double strip prototype of the J-PET detector and $^{22}$Na sodium isotope as a source of annihilation gamma quanta.The detector was built out from plastic scintillator strips with dimensions of 5 mm x 19 mm x 300 mm, optically connected at both sides to photomultipliers,from which signals were sampled by means of the Serial Data Analyzer.Using the introduced method, the spatial and TOF resolution of about 1.3 cm ($σ$) and 125 ps ($σ$) were established, respectively.

preprint2015arXiv

A pilot study of the novel J-PET plastic scintillator with 2-(4-styrylphenyl)benzoxazole as a wavelength shifter

For the first time a molecule of 2-(4-styrylphenyl)benzoxazole containing benzoxazole and stilbene groups is applied as a scintillator dopant acting as a wavelength shifter. In this article a light yield of the plastic scintillator, prepared from styrene doped with 2 wt% of 2,5-diphenylbenzoxazole and 0.03 wt% of 2-(4-styrylphenyl)benzoxazole, is determined to be as large as 60% $\pm$ 2% of the anthracene light output. There is a potential to improve this value in the future by the optimization of the additives concentrations.

preprint2015arXiv

Analysis framework for the J-PET scanner

J-PET analysis framework is a flexible, lightweight, ROOT-based software package which provides the tools to develop reconstruction and calibration procedures for PET tomography. In this article we present the implementation of the full data-processing chain in the J-PET framework which is used for the data analysis of the J-PET tomography scanner. The Framework incorporates automated handling of PET setup parameters' database as well as high level tools for building data reconstruction procedures. Each of these components is briefly discussed.

preprint2015arXiv

Application of the Compress Sensing Theory for Improvement of the TOF Resolution in a Novel J-PET Instrument

Nowadays, in Positron Emission Tomography (PET) systems, a Time of Flight information is used to improve the image reconstruction process. In Time of Flight PET (TOF-PET), fast detectors are able to measure the difference in the arrival time of the two gamma rays, with the precision enabling to shorten significantly a range along the line-of-response (LOR) where the annihilation occurred. In the new concept, called J-PET scanner, gamma rays are detected in plastic scintillators. In a single strip of J-PET system, time values are obtained by probing signals in the amplitude domain. Owing to Compress Sensing theory, information about the shape and amplitude of the signals is recovered. In this paper we demonstrate that based on the acquired signals parameters, a better signal normalization may be provided in order to improve the TOF resolution. The procedure was tested using large sample of data registered by a dedicated detection setup enabling sampling of signals with 50 ps intervals. Experimental setup provided irradiation of a chosen position in the plastic scintillator strip with annihilation gamma quanta.

preprint2015arXiv

Compressive Sensing of Signals Generated in Plastic Scintillators in a Novel J-PET Instrument

The J-PET scanner, which allows for single bed imaging of the whole human body, is currently under development at the Jagiellonian University. The dis- cussed detector offers improvement of the Time of Flight (TOF) resolution due to the use of fast plastic scintillators and dedicated electronics allowing for sam- pling in the voltage domain of signals with durations of few nanoseconds. In this paper we show that recovery of the whole signal, based on only a few samples, is possible. In order to do that, we incorporate the training signals into the Tikhonov regularization framework and we perform the Principal Component Analysis decomposition, which is well known for its compaction properties. The method yields a simple closed form analytical solution that does not require iter- ative processing. Moreover, from the Bayes theory the properties of regularized solution, especially its covariance matrix, may be easily derived. This is the key to introduce and prove the formula for calculations of the signal recovery error. In this paper we show that an average recovery error is approximately inversely proportional to the number of acquired samples.

preprint2015arXiv

K$^-$ absorption on two nucleons and ppK$^-$ bound state search in the $Σ^0$p final state

We report the measurement of K$^-$ absorption processes in the $Σ^0$p final state and the first exclusive measurement of the two nucleon absorption (2NA) with the KLOE detector. The 2NA process without further interactions is found to be 12\% of the sum of all other contributing processes, including absorption on three and more nucleons or 2NA followed by final state interactions with the residual nucleons. We also determine the possible contribution of the ppK$^-$ bound state to the $Σ^0$p final state. A yield of ppK$^- /\mathrm{K^-_{stop}}$ is found to be $(0.044 \pm 0.009\, stat ^{+ 0.004} _{- 0.005} \,syst) \cdot 10^{-2}$ but its statistical significance based on an F-test is only 1$σ$.

preprint2015arXiv

Limit on the production of a low-mass vector boson in $\mathrm{e}^{+}\mathrm{e}^{-} \to \mathrm{U}γ$, $\mathrm{U} \to \mathrm{e}^{+}\mathrm{e}^{-}$ with the KLOE experiment

The existence of a new force beyond the Standard Model is compelling because it could explain several striking astrophysical observations which fail standard interpretations. We searched for the light vector mediator of this dark force, the $\mathrm{U}$ boson, with the KLOE detector at the DA$Φ$NE $\mathrm{e}^{+}\mathrm{e}^{-}$ collider. Using an integrated luminosity of 1.54 fb$^{-1}$, we studied the process $\mathrm{e}^{+}\mathrm{e}^{-} \to \mathrm{U}γ$, with $\mathrm{U} \to \mathrm{e}^{+}\mathrm{e}^{-}$, using radiative-return to search for a resonant peak in the dielectron invariant-mass distribution. We did not find evidence for a signal, and set a 90\%~CL upper limit on the mixing strength between the Standard Model photon and the dark photon, $\varepsilon^2$, at $10^{-6}$--$10^{-4}$ in the 5--520~MeV/c$^2$ mass range.

preprint2015arXiv

Measurement of the strong interaction induced shift and width of the 1s state of kaonic deuterium at J-PARC

The antikaon-nucleon interaction close to threshold provides crucial information on the interplay between spontaneous and explicit chiral symmetry breaking in low-energy QCD. In this context the importance of kaonic deuterium X-ray spectroscopy has been well recognized, but no experimental results have yet been obtained due to the difficulty of the measurement. We propose to measure the shift and width of the kaonic deuterium 1s state with an accuracy of 60 eV and 140 eV respectively at J-PARC. These results together with the kaonic hydrogen data (KpX at KEK, DEAR and SIDDHARTA at DAFNE) will then permit the determination of values of both the isospin I=0 and I=1 antikaon-nucleon scattering lengths and will provide the most stringent constraints on the antikaon-nucleon interaction, promising a breakthrough. Refined Monte Carlo studies were performed, including the investigation of background suppression factors for the described setup. These studies have demonstrated the feasibility of determining the shift and width of the kaonic deuterium atom 1s state with the desired accuracy of 60 eV and 140 eV.

preprint2015arXiv

PALS investigations of free volumes thermal expansion of J-PET plastic scintillator synthesized in polystyrene matrix

The polystyrene dopped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenyl)benzoxazole as a wavelength shifter, prepared as a plastic scintillator was investigated using positronium probe in wide range of temperatures from 123 to 423 K. Three structural transitions at 260 K, 283 K and 370 K were found in the material. In the o-Ps intensity dependence on temperature, the significant hysteresis is observed. Heated to 370 K, the material exhibits the o-Ps intensity variations in time.

preprint2015arXiv

Processing optimization with parallel computing for the J-PET tomography scanner

The Jagiellonian-PET (J-PET) collaboration is developing a prototype TOF-PET detector based on long polymer scintillators. This novel approach exploits the excellent time properties of the plastic scintillators, which permit very precise time measurements. The very fast, FPGA-based front-end electronics and the data acquisition system, as well as, low- and high-level reconstruction algorithms were specially developed to be used with the J-PET scanner. The TOF-PET data processing and reconstruction are time and resource demanding operations, especially in case of a large acceptance detector, which works in triggerless data acquisition mode. In this article, we discuss the parallel computing methods applied to optimize the data processing for the J-PET detector. We begin with general concepts of parallel computing and then we discuss several applications of those techniques in the J-PET data processing.

preprint2015arXiv

Project of the underwater system for chemical threat detection

In this article we describe a novel method for the detection of explosives and other hazardous substances in the marine environment using neutron activation. Unlike the other considered methods based on this technique we propose to use guides forneutron and gamma quanta which speeds up and simplifies identification. Moreover, it may provide a determination of the density distribution of a dangerous substance. First preliminary results of Monte Carlo simulations dedicated for design of a device exploiting this method are also presented.

preprint2015arXiv

Reconstruction of hit-time and hit-position of annihilation quanta in the J-PET detector using the Mahalanobis distance

The J-PET detector being developed at Jagiellonian University, is a Positron Emission Tomograph composed of the long strips of polymer scintillators. At the same time it is a detector system which will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit-time and hit-position of the gamma quantum. In order to take advantage of this fact a dedicated sampling front-end electronics which enables to sample signals in voltage domain with the time precision of about 20 ps and novel reconstruction method based on the comparison of examined signal with the model signals stored in the library has been developed. As a measure of the similarity we use the Mahalanobis distance. The achievable position and time-resolution depends on number and values of the threshold levels at which the signal is sampled. A reconstruction method, as well as preliminary results are presented and discussed.

preprint2015arXiv

Searches for discrete symmetries violation in ortho-positronium decay using the J-PET detector

In this paper we present prospects for using the J-PET detector to search for discrete symmetries violations in a purely leptonic system of the positronium atom. We discuss tests of CP and CPT symmetries by means of ortho-positronium decays into three photons. No zero expectation values for chosen correlations between ortho-positronium spin and momentum vectors of photons would imply the existence of physics phenomena beyond the Standard Model. Previous measurements resulted in violation amplitude parameters for CP and CPT symmetries consistent with zero, with an uncertainty of about 10-3. The J-PET detector allows to determine those values with better precision thanks to a unique time and angular esolution combined with a high geometrical acceptance. Achieving the aforementioned is possible due to application of polymer scintillators instead of crystals as detectors of annihilation quanta.

preprint2015arXiv

Studies of unicellular micro-organisms Saccharomyces cerevisiae by means of Positron Annihilation Lifetime Spectroscopy

Results of Positron Annihilation Lifetime Spectroscopy (PALS) and microscopic studies on simple microorganisms: brewing yeasts are presented. Lifetime of ortho - positronium (o-Ps) were found to change from 2.4 to 2.9 ns (longer lived component) for lyophilised and aqueous yeasts, respectively. Also hygroscopicity of yeasts in time was examined, allowing to check how water - the main component of the cell - affects PALS parameters, thus lifetime of o-Ps were found to change from 1.2 to 1.4 ns (shorter lived component) for the dried yeasts. The time sufficient to hydrate the cells was found below 10 hours. In the presence of liquid water an indication of reorganization of yeast in the molecular scale was observed. Microscopic images of the lyophilised, dried and wet yeasts with best possible resolution were obtained using Inverted Microscopy (IM) and Environmental Scanning Electron Microscopy (ESEM) methods. As a result visible changes to the surface of the cell membrane were observed in ESEM images.

preprint2014arXiv

A novel method for calibration and monitoring of time synchronization of TOF-PET scanners by means of cosmic rays

All of the present methods for calibration and monitoring of TOF-PET scanner detectors utilize radioactive isotopes such as e.g. $^{22}$Na or $^{68}$Ge, which are placed or rotate inside the scanner. In this article we describe a novel method based on the cosmic rays application to the PET calibration and monitoring methods. The concept allows to overcome many of the drawbacks of the present methods and it is well suited for newly developed TOF-PET scanners with a large longitudinal field of view. The method enables also monitoring of the quality of the scintillator materials and in general allows for the continuous quality assurance of the PET detector performance.

preprint2014arXiv

Close to threshold eta' meson production in proton-proton collisions at COSY-11

Intensive quest for the eta and eta' bound states is currently ongoing at both theoretical and experimental levels e.g. at COSY, ELSA, GSI, JINR, JPARC, LPI, and MAMI. These studies were already supported by data provided by the COSY-11 collaboration including determination of the total width of the eta' meson. In addition, the first rough estimation of the eta'-N interaction from the excitation function of the cross section for the pp-->pp eta' reaction was also performed. Recent precise measurement in this field from the COSY-11 experiment allows to summarize results on the eta' meson production cross section in proton-proton collisions at COSY-11.

preprint2014arXiv

Combined analysis of the $K^{+}K^{-}$ interaction using near threshold $pp \to ppK^+K^-$ data

The $K^{+}K^{-}$ final state interaction was investigated based on both the $K^{+}K^{-}$ invariant mass distributions measured at excess energies of Q = 10 and 28 MeV and the near threshold excitation function for the $pp \to ppK^{+}K^{-}$ reaction. The $K^+K^-$ final state enhancement factor was parametrized using the effective range expansion. The effective range of the $K^+K^-$ interaction was estimated to be: $\mathrm{Re}(b_{K^{+}K^{-}}) = -0.1 \pm 0.4_{stat} \pm 0.3_{sys} \mathrm{fm}$ and $\mathrm{Im}(b_{K^{+}K^{-}}) = 1.2^{+0.1_{stat}+0.2_{sys}}_{-0.2_{stat}-0.0_{sys}} \mathrm{fm}$, and the determined real and imaginary parts of the $K^+K^-$ scattering length amount to: $|\mathrm{Re}(a_{K^{+}K^{-}})| = 8.0^{+6.0_{stat}}_{-4.0_{stat}} \mathrm{fm}$ and $\mathrm{Im}(a_{K^{+}K^{-}}) = 0.0^{+20.0_{stat}}_{-5.0_{stat}} \mathrm{fm}$.

preprint2014arXiv

Database and data structure for the novel TOF-PET detector developed for J-PET project

The complexity of the hardware and the amount of data collected during the PET imaging process require application of modern methods of efficient data organization and processing. In this article we will discuss the data structures and the flow of collected data from the novel TOF-PET medical scanner which is being developed at the Jagiellonian University. The developed data format reflects: registration process of the gamma quanta emitted from positron-electron annihilation, Front-End Electronic (FEE) structure and required input information for the image reconstruction. In addition, the system database fulfills possible demands of the evolving J-PET project.

preprint2014arXiv

Determination of the eta'-proton scattering length in free space

Taking advantage of both the high mass resolution of the COSY-11 detector and the high energy resolution of the low-emittance proton-beam of the Cooler Synchrotron COSY we determine the excitation function for the pp --> pp eta' reaction close-to-threshold. Combining these data with previous results we extract the scattering length for the eta'-proton potential in free space to be Re(a_{p eta'}) = 0+-0.43 fm and Im(a_{p eta'}) = 0.37(+0.40)(-0.16) fm.

preprint2014arXiv

Determination of the map of efficiency of the J-PET detector with the GATE package

A novel PET detector consisting of strips of polymer scintillators is being developed by the J-PET Collaboration. The map of efficiency and the map of geometrical acceptance of the 2-strip J-PET scanner are presented. Map of efficiency was determined using the Monte Carlo simulation software GATE based on GEANT4. Both maps were compared using method based on the chi2 test.

preprint2014arXiv

J-PET analysis framework for the prototype TOF-PET detector

Novel TOF-PET scanner solutions demand, apart from the state of the art detectors, software for fast processing of the gathered data, monitoring of the whole scanner and reconstruction of the PET image. In this article we present an analysis framework for the novel STRIP-PET scanner developed by the J-PET collaboration in the Institute of Physics of the Jagiellonian University. This software is based on the ROOT package used in many particle physics experiments.

preprint2014arXiv

Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography

Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals and an example of an application of the method for a single module with a 30 cm long plastic strip, read out on both ends by Hamamatsu R4998 photomultipliers. The sampling scheme to generate a vector with samples of a PET event waveform with respect to four user-defined amplitudes is introduced. The experimental setup provides irradiation of a chosen position in the plastic scintillator strip with an annihilation gamma quanta of energy 511~keV. The statistical test for a multivariate normal (MVN) distribution of measured vectors at a given position is developed, and it is shown that signals sampled at four thresholds in a voltage domain are approximately normally distributed variables. With the presented method of a vector analysis made out of waveform samples acquired with four thresholds, we obtain a spatial resolution of about 1 cm and a timing resolution of about 80 ps

preprint2014arXiv

Phenomenology of the $ppK^+K^-$ system near threshold

In this article studies of the near threshold $pp\to ppK^+K^-$ reaction conducted with the COSY-11 and the ANKE detectors are reviewed. In particular recent investigations on the $K^+K^-$ final state interaction are revisited taking into account updated cross sections of the COSY-11 experiment. These studies resulted in the new value of $K^+K^-$ effective range amounting to: $\mathrm{Re}(b_{K^{+}K^{-}}) = -0.2^{+0.8_{stat}~+0.4_{sys}}_{-0.6_{stat}~-0.4_{sys}}~\mathrm{fm}$ and $\mathrm{Im}(b_{K^{+}K^{-}}) = 1.2^{~+0.5_{stat}~+0.3_{sys}}_{~-0.3_{stat}~-0.3_{sys}}~\mathrm{fm}$. The determined real and imaginary parts of the $K^+K^-$ scattering length were estimated to be: $\left|\mathrm{Re}(a_{K^{+}K^{-}})\right| = 10^{~+17_{stat}}_{~-10_{stat}}~\mathrm{fm}$ and $\mathrm{Im}(a_{K^{+}K^{-}}) = 0^{~+37_{stat}}_{~-10_{stat}}~\mathrm{fm}$.

preprint2014arXiv

Study of Dalitz decay phi -> eta e+e- with KLOE detector

We have studied the vector to pseudoscalar conversion decay phi -> eta e+e-, with eta -> pi0pi0pi0, with the KLOE detector at DAPHNE. The data set of 1.7 fb-1 of e+e- collisions at sqrt(s)~Mphi contains a clear conversion decay signal of ~31,000 events from which we measured a value of BR(phi -> eta e+e-)=(1.075+-0.007+-0.038)x10-4. The same sample is used to determine the transition form factor by a fit to the e+e- invariant mass spectrum, obtaining b(phi eta) =(1.17 +- 0.10 + 0.07) GeV-2, that improves by a factor of five the precision of the previous measurement and is in good agreement with VMD expectations.

preprint2014arXiv

Test of a single module of the J-PET scanner based on plastic scintillators

Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this article we report on tests of a single detection module built out from BC-420 plastic scintillator strip (with dimensions of 5x19x300mm^3) read out at two ends by Hamamatsu R5320 photomultipliers. The measurements were performed using collimated beam of annihilation quanta from the 68Ge isotope and applying the Serial Data Analyzer (Lecroy SDA6000A) which enabled sampling of signals with 50ps intervals. The time resolution of the prototype module was established to be better than 80ps (sigma) for a single level discrimination. The spatial resolution of the determination of the hit position along the strip was determined to be about 0.93cm (sigma) for the annihilation quanta. The fractional energy resolution for the energy E deposited by the annihilation quanta via the Compton scattering amounts to sigma(E)/E = 0.044/sqrt(E[MeV]) and corresponds to the sigma(E)/E of 7.5% at the Compton edge.

preprint2014arXiv

Test of CPT and Lorentz symmetry in entangled neutral kaons with the KLOE experiment

Neutral kaon pairs produced in phi decays in anti-symmetric entangled state can be exploited to search for violation of CPT symmetry and Lorentz invariance. We present an analysis of the CP-violating process phi->K_S K_L->pi+pi-pi+pi- based on 1.7 fb-1 of data collected by the KLOE experiment at the Frascati phi-factory DAFNE. The data are used to perform a measurement of the CPT-violating parameters Delta_amu for neutral kaons in the contest of the Standard Model Extension framework. The parameters measured in the reference frame of the fixed stars are: Delta_ao = (-6.0 +- 7.7_{stat} +- 3.1_{syst}) x 10^{-18} GeV Delta_ax = ( 0.9 +- 1.5_{stat} +- 0.6_{syst}) x 10^{-18} GeV Delta_ay = (-2.0 +- 1.5_{stat} +- 0.5_{syst}) x 10^{-18} GeV Delta_az = ( 3.1 +- 1.7_{stat} +- 0.5_{syst}) x 10^{-18} GeV These are presently the most precise measurements in the quark sector of the Standard Model Extension.

preprint2013arXiv

A new limit on the CP violating decay KS -> 3pi0 with the KLOE experiment

We have carried out a new direct search for the CP violating decay KS -> 3pi0 with 1.7 fb^-1 of e+e- collisions collected by the KLOE detector at the phi-factory DAFNE. We have searched for this decay in a sample of about 5.9 x 10^8 KS KL events tagging the KS by means of the KL interaction in the calorimeter and requiring six prompt photons. With respect to our previous search, the analysis has been improved by increasing of a factor four the tagged sample and by a more effective background rejection of fake KS tags and spurious clusters. We find no candidates in data and simulated background samples, while we expect 0.12 standard model events. Normalizing to the number of KS -> 2pi0 events in the same sample, we set the upper limit on BR(KS -> 3pi0 < 2.6 x 10^-8 at 90% C.L., five times lower than the previous limit. We also set the upper limit on the eta_000 parameter, |eta_000 | < 0.0088 at 90% C.L., improving by a factor two the latest direct measurement.

preprint2013arXiv

A novel method based solely on FPGA units enabling measurement of time and charge of analog signals in Positron Emission Tomography

This article presents a novel technique for precise measurement of time and charge based solely on FPGA (Field Programmable Gate Array) device and few satellite discrete electronic components used in Positron Emission Tomography (PET). Described approach simplifies electronic circuits, reduces the power consumption, lowers costs, merges front-end electronics with digital electronics and also makes more compact final design. Furthermore, it allows to measure time when analog signals cross a reference voltage at different threshold levels with a very high precision of $\sim$ 10ps (rms) and thus enables sampling of signals in a voltage domain.

preprint2013arXiv

Application of Compressive Sensing Theory for the Reconstruction of Signals in Plastic Scintillators

Compressive Sensing theory says that it is possible to reconstruct a measured signal if an enough sparse representation of this signal exists in comparison to the number of random measurements. This theory was applied to reconstruct signals from measurements of plastic scintillators. Sparse representation of obtained signals was found using SVD transform.

preprint2013arXiv

Application of WLS strips for position determination in Strip PET tomograph based on plastic scintillators

A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this method for improvement of position resolution in newly proposed PET detectors based on plastic scintillators is presented. The method enables to reduce parallax errors in reconstruction of images which occurs in the presently used Positron Emission Tomography scanners.

preprint2013arXiv

Applications of neutron activation spectroscopy

Since the discovery in 1932, neutrons became a basis of many methods used not only in research, but also in industry and engineering. Among others, the exceptional role in the modern nuclear engineering is played by the neutron activation spectroscopy, based on the interaction of neutron flux with atomic nuclei. In this article we shortly describe application of this method in medicine and detection of hazardous substances.

preprint2013arXiv

Calibration of photomultipliers gain used in the J-PET detector

Photomultipliers are commonly used in commercial PET scanner as devices which convert light produced in scintillator by gamma quanta from positron-electron annihilation into electrical signal. For proper analysis of obtained electrical signal, a photomultiplier gain curve must be known, since gain can be significantly different even between photomultipliers of the same model. In this article we describe single photoelectron method used for photomultipliers calibration applied for J-PET scanner, a novel PET detector being developed at the Jagiellonian University. Description of calibration method, an example of calibration curve and gain of few R4998 Hamamatsu photomultipliers are presented.

preprint2013arXiv

Limit on the production of a light vector gauge boson in phi meson decays with the KLOE detector

We present a new limit on the production of a light dark-force mediator with the KLOE detector at DAPHNE. This boson, called U, has been searched for in the decay phi --> eta U, U --> e+ e-, analyzing the decay eta --> pi0 pi0 pi0 in a data sample of 1.7 fb-1. No structures are observed in the e+e- invariant mass distribution over the background. This search is combined with a previous result obtained from the decay eta --> pi+ pi- pi0, increasing the sensitivity. We set an upper limit at 90% C.L. on the ratio between the U boson coupling constant and the fine structure constant of alpha'/alpha < 1.7x10^-5 for 30<M_U<400 MeV and alpha'/alpha < 8x10^-6 for the sub-region 50<M_U<210 MeV. This result assumes the Vector Meson Dominance expectations for the phietagamma^* transition form factor. The dependence of this limit on the transition form factor has also been studied.

preprint2013arXiv

Novel detector systems for the Positron Emission Tomography

In this contribution we describe a novel solution for the construction of Positron Emission Tomograph. We present the device allowing for determination of the impact position as well as time and deph of interaction of the annihilation gamma quanta. The device is comprised of scintillation chamber consisting of organic scintillators surrounding the body of the patient. We discuss two possible solutions: (i) the tomograph built out of scintillator strips, and (ii) the tomograph built out of the scintillator plates. The application of the fast scintillators will enable to take advantage of the difference between time of the registration of the annihilation quanta. The invented method will permit to use a thick layers of detector material with the possibility of measuring the depth of the gamma quantum interaction (DOI) and the determination of their time of flight (TOF), and will allow for increasing the size of the diagnostic chamber without a significant increase of costs. The method is a subject of two patent applications which are based on the techniques used in the particle physics experiments.

preprint2013arXiv

Precision measurement of $σ(e^+e^-\rightarrowπ^+π^-γ)/σ(e^+e^-\rightarrow μ^+μ^-γ)$ and determination of the $π^+π^-$ contribution to the muon anomaly with the KLOE detector

We have measured the ratio $σ(e^+e^-\rightarrowπ^+π^-γ)/σ(e^+e^-\rightarrow μ^+μ^-γ)$, with the KLOE detector at DA$Φ$NE for a total integrated luminosity of $\sim$ 240 pb$^{-1}$. From this ratio we obtain the cross section $σ(e^+e^-\rightarrowπ^+π^-)$. From the cross section we determine the pion form factor $|F_π|^2$ and the two-pion contribution to the muon anomaly $a_μ$ for $0.592<M_{ππ}<0.975$ GeV, $Δ^{ππ} a_μ$= $({\rm 385.1\pm1.1_{stat}\pm2.7_{sys+theo}})\times10^{-10}$. This result confirms the current discrepancy between the Standard Model calculation and the experimental measurement of the muon anomaly.

preprint2013arXiv

Recent results on hadron physics at KLOE

One of the basic motivations of the KLOE and KLOE-2 collaborations is the test of fundamental symmetries and the search for phenomena beyond the Standard Model via the hadronic and leptonic decays of ground-state mesons and via their production in the fusion of virtual gamma quanta exchanged between colliding electrons and positrons. This contribution includes brief description of results of recent analysis of the KLOE data aimed at (i) the search for the dark matter boson, (ii) determination of the hadronic and light-by-light contributions to the g-2 muon anomaly and (iii) tests of QCD anomalies.

preprint2013arXiv

Search for the $ K_S to 3 π^0$ decay with the KLOE detector

The $K_S \to 3 π^0$ decay is a pure CP violating process which, assuming CPT invariance, allows one to investigate direct CP violation. This decay has not been observed so far, and the best upper limit on the branching ratio $BR(K_S to 3π^0) < 1.2 \cdot 10^{-7}$ is two orders of magnitude larger than predictions based on the Standard Model: $BR(K_S \to 3π^0) \sim 2 \cdot 10^{-9}$. In this article we present the search for the $K_S \to 3π^0$ decay performed with the KLOE detector operating at the DAFNE Φ-factory at the Frascati Laboratory. We describe the analysis techniques used in the background rejection and signal events selection as well as the evaluation of almost five times lower upper limit on the $K_S \to 3π^0$ branching ratio. We discuss shortly also the perspectives for a new measurement using the KLOE-2 apparatus equipped with a new inner tracker and the calorimeters at low theta angle.

preprint2013arXiv

Search for the CP symmetry violation in the decays of Ks mesons using the KLOE detector

The aim of this work was to determine the KS -> 3pi0 decay branching ratio and a modulus of the eta000 parameter, defined as the ratio of amplitudes for KS -> 3 pi0 to KL -> 3pi0 decays, which characterizes the CP symmetry violation in this decay. The measurement has been carried out with the KLOE detector operating at the phi-factory DAFNE in the Italian National Center for Nuclear Physics in Frascati. The KS mesons were identified with high efficiency via registration of these KL mesons which crossed the drift chamber without decaying and then interacted with the KLOE electromagnetic calorimeter. The KS four-momentum vector was then determined using the registered position of the KL meson and the known momentum of the phi meson. Next, the search for the KS -> 3pi0 -> 6gamma decay was carried out by the selection of events with six gamma quanta which momenta were reconstructed using time and energy measured by the electromagnetic calorimeter. To increase the signal over background ratio after identification of the KS meson and requiring six reconstructed photons a discriminant analysis is performed. It is based on kinematical fit, testing of the signal and background hypotheses and exploiting of the differences in kinematics of the KS decays into 2pi0 and 3pi0. Hence, we have obtained the upper limit on the KS -> 3pi0 branching ratio at the 90% confidence level BR(KS -> 3pi0)< 2.7 x 10^-8, which is almost five times lower than the latest published result. The search for the KS -> 3pi0 decay presented in this work failed to detect a signal of sufficient statistical significance. This upper limit can be translated into a limit on the modulus of the eta000 parameter amounting to: |eta000| < 0.009 at the 90% confidence level.

preprint2013arXiv

Simulations of gamma quanta scattering in a single module of the J-PET detector

This article describes simulations of scattering of annihilation gamma quanta in a strip of plastic scintillator. Such strips constitute basic detection modules in a newly proposed Positron Emission Tomography which utilizes plastic scintillators instead of inorganic crystals. An algorithm simulating chain of Compton scatterings was elaborated and series of simulations have been conducted for the scintillator strip with the cross section of 5 mm x 19 mm. Obtained results indicate that secondary interactions occur only in the case of about 8% of events and out of them only 25$\%$ take place in the distance larger than 0.5 cm from the primary interaction. It was also established that light signals produced at primary and secondary interactions overlap with the delay which distribution is characterized by FWHM of about 40 ps.

preprint2013arXiv

STRIP-PET: a novel detector concept for the TOF-PET scanner

We briefly present a design of a new PET scanner based on strips of polymer scintillators arranged in a barrel constituting a large acceptance detector. The solution proposed is based on the superior timing properties of the polymer scintillators. The position and time of the reaction of the gamma quanta in the detector material will be determined based on the time of arrival of light signals to the edges of the scintillator strips.

preprint2013arXiv

Study of the $K^+K^-$ final state interaction in proton-proton and electron-positron collisions

The strength of the kaon--antikaon interaction is a crucial quantity for many physics topics. It is for example, an important parameter in the discussion on the nature of the scalar resonances $a_{0}(980)$ and $f_{0}(980)$, in particular for their interpretation as $K\bar{K}$ molecules. So far, one of the few possibilities to study this interaction is the kaon pair production in multi particle exit channels like $pp \to ppK^+K^-$. In this article we present the latest results of the $K^+K^-$ interaction preformed based on near threshold data gathered at the Cooler Synchrotron COSY. We discuss also shortly perspectives for a new measurement of the kaon--antikaon scattering length in the $e^+e^-$ collisions.

preprint2013arXiv

System Response Kernel Calculation for List-mode Reconstruction in Strip PET Detector

Reconstruction of the image in Positron Emission Tomographs (PET) requires the knowledge of the system response kernel which describes the contribution of each pixel (voxel) to each tube of response (TOR). This is especially important in list-mode reconstruction systems, where an efficient analytical approximation of such function is required. In this contribution, we present a derivation of the system response kernel for a novel 2D strip PET.

preprint2013arXiv

TOF-PET detector concept based on organic scintillators

In this contribution we present a new concept of the large acceptance detector systems based on organic scintillators which may allow for simultaneous diagnostic of large fraction of the human body. Novelty of the concept lies in employing large blocks of polymer scintillators instead of crystals as detectors of annihilation quanta, and in using predominantly the timing of signals instead of their amplitudes.

preprint2012arXiv

Measurement of Γ(η-> π^+π^-γ)/Γ(η-> π^+π^-π^0) with the KLOE Detector

The ratio R_η=Γ(η-> π^+π^-γ)/Γ(η-> π^+π^-π^0) has been measured by analyzing 22 million ϕ\to ηγdecays collected by the KLOE experiment at DA\PhiNE, corresponding to an integrated luminosity of 558 pb^{-1}. The η\to π^+π^-γproceeds both via the ρresonant contribution, and possibly a non-resonant direct term, connected to the box anomaly. Our result, R_η= 0.1856\pm 0.0005_{stat} \pm 0.0028_{syst}, points out a sizable contribution of the direct term to the total width. The di-pion invariant mass for the η-> π^+π^-γdecay could be described in a model-independent approach in terms of a single free parameter, α. The determined value of the parameter αis α= (1.32 \pm 0.08_{stat} +0.10/-0.09_{syst}\pm 0.02_{theo}) GeV^{-2}

preprint2012arXiv

Measurement of η meson production in γγ interactions and Γ(η-->γγ) with the KLOE detector

We present a measurement of η meson production in photon-photon interactions produced by electron-positron beams colliding with \sqrt{s}=1 GeV. The measurement is done with the KLOE detector at the ϕ-factory DAΦNE with an integrated luminosity of 0.24 fb^{-1}. The e^+e^- --> e^+e^-η cross section is measured without detecting the outgoing electron and positron, selecting the decays η-->π^+π^-π^0 and η-->π^0π^0π^0. The most relevant background is due to e^+e^- --> ηγ when the monochromatic photon escapes detection. The cross section for this process is measured as σ(e^+e^- -->ηγ) = (856 \pm 8_{stat} \pm 16_{syst}) pb. The combined result for the e^+e^- -->e^+e^-η cross section is σ(e^+e^- -->e^+e^-η) = (32.72 \pm 1.27_{stat} \pm 0.70_{syst}) pb. From this we derive the partial width Γ(η-->γγ) = (520 \pm 20_{stat} \pm 13_{syst}) eV. This is in agreement with the world average and is the most precise measurement to date.

preprint2011arXiv

$γγ$ physics with the KLOE experiment

The processes $e^+e^-\to e^+e^-X$, with $X$ being either the $η$ meson or $π^0π^0$, are studied at DA$Φ$NE, with $e^+e^-$ beams colliding at $\sqrt{s}\simeq1$ GeV, below the $ϕ$ resonance peak. The data sample is from an integrated luminosity of 240 pb$^{-1}$, collected by the KLOE experiment without tagging of the outgoing $e^+e^-$. Preliminary results are presented on the observation of the $γγ\toη$ process, with both $η\toπ^+π^-π^0$ and $η\toπ^0π^0π^0$ channels, and the evidence for $γγ\toπ^0π^0$ production at low $π^0π^0$ invariant mass.

preprint2011arXiv

Measurement of $Γ(η\to π^+π^-γ)/Γ(η\to π^+π^-π^0)$ with KLOE experiment

We report the measurement of the ratio $Γ(η\to π^+π^-γ)/Γ(η\to π^+π^-π^0)$ analyzing a large sample of $ϕ\to ηγ$ decays recorded with the KLOE experiment at the DA$Φ$NE $e^+ e^-$ collider, corresponding to an integrated luminosity of 558 pb$^{-1}$. The $η\to π^+π^-γ$ process is supposed to proceed both via a resonant contribution, mediated by the $ρ$ meson, and a non resonant direct term, connected to the box anomaly. The presence of the direct term affects the partial width value. Our result $R_η=Γ(η\to π^+ π^- γ)/Γ(η\to π^+ π^- π^0)= 0.1838\pm 0.0005_{stat} \pm 0.0030_{syst}$ is in agreement with a recent CLEO measurement, which differs by more 3 $σ$ from the average of previous results.

preprint2010arXiv

Determination of the total width of the eta' meson

Taking advantage of both the low-emittance proton-beam of the Cooler Synchrotron COSY and the high momentum precision of the COSY-11 detector system, the mass distribution of the eta' meson was measured with a resolution of 0.33 MeV/c^2 (FWHM), improving the experimental mass resolution by almost an order of magnitude with respect to previous results. Based on the sample of more than 2300 reconstructed pp --> pp eta' events the total width of the eta' meson was determined to be 0.226 +- 0.017(stat.) +- 0.014(syst.) MeV/c^2.

preprint2010arXiv

Measurement of the invariant mass distributions for the pp -> ppeta' reaction at excess energy of Q = 16.4 MeV

The proton-proton and proton-eta' invariant mass distributions have been determined for the pp -> ppeta' reaction at an excess energy of Q = 16.4 MeV. The measurement was carried out using the COSY-11 detector setup and the proton beam of the cooler synchrotron COSY. The shapes of the determined invariant mass distributions are similar to those of the pp -> ppeta reaction and reveal an enhancement for large relative proton-proton momenta. This result, together with the fact that the proton-eta interaction is much stronger that the proton-eta' interaction, excludes the hypothesis that the observed enhancement is caused by the interaction between the proton and the meson.

preprint2010arXiv

Physics with the KLOE-2 experiment at the upgraded DA$ϕ$NE

Investigation at a $ϕ$--factory can shed light on several debated issues in particle physics. We discuss: i) recent theoretical development and experimental progress in kaon physics relevant for the Standard Model tests in the flavor sector, ii) the sensitivity we can reach in probing CPT and Quantum Mechanics from time evolution of entangled kaon states, iii) the interest for improving on the present measurements of non-leptonic and radiative decays of kaons and eta/eta$^\prime$ mesons, iv) the contribution to understand the nature of light scalar mesons, and v) the opportunity to search for narrow di-lepton resonances suggested by recent models proposing a hidden dark-matter sector. We also report on the $e^+ e^-$ physics in the continuum with the measurements of (multi)hadronic cross sections and the study of gamma gamma processes.

preprint2010arXiv

Proposal for taking data with the KLOE-2 detector at the DA$Φ$NE collider upgraded in energy

This document reviews the physics program of the KLOE-2 detector at DA$Φ$NE upgraded in energy and provides a simple solution to run the collider above the $ϕ$-peak (up to 2, possibly 2.5 GeV). It is shown how a precise measurement of the multihadronic cross section in the energy region up to 2 (possibly 2.5) GeV would have a major impact on the tests of the Standard Model through a precise determination of the anomalous magnetic moment of the muon and the effective fine-structure constant at the $M_Z$ scale. With a luminosity of about $10^{32}$cm$^{-2}$s$^{-1}$, DA$Φ$NE upgraded in energy can perform a scan in the region from 1 to 2.5 GeV in one year by collecting an integrated luminosity of 20 pb$^{-1}$ (corresponding to a few days of data taking) for single point, assuming an energy step of 25 MeV. A few years of data taking in this region would provide important tests of QCD and effective theories by $γγ$ physics with open thresholds for pseudo-scalar (like the $η'$), scalar ($f_0,f'_0$, etc...) and axial-vector ($a_1$, etc...) mesons; vector-mesons spectroscopy and baryon form factors; tests of CVC and searches for exotics. In the final part of the document a technical solution for the energy upgrade of DA$Φ$NE is proposed.

preprint2010arXiv

Study of the K+K- Interaction at COSY-11

In this article we present studies of the near threshold pp-->ppK+K- reaction in view of the K+K- final state interaction. The investigations include analysis of both the low-energy K+K- invariant mass distributions measured by COSY-11 collaboration at excess energies of Q = 10 MeV and Q = 28 MeV and the near threshold excitation function for the pp-->ppK+K- reaction. As a result of these studies we have estimated the K+K- scattering length more precise compared to the previous analysis based only on the analysis of the differential cross sections.

preprint2010arXiv

Two-proton correlation function for the pp -> pp+eta and pp -> pp+pions reactions

For the very first time, the correlation femtoscopy method is applied to a kinematically complete measurement of meson production in the collisions of hadrons. A two-proton correlation function was derived from the data for the pp -> ppX reaction, measured near the threshold of eta meson production. A technique developed for the purpose of this analysis permitted to establish the correlation function separately for the production of the pp+eta and of the pp+pions systems. The shape of the two-proton correlation function for the ppeta differs from that for the pp(pions) and both do not show a peak structure opposite to results determined for inclusive measurements of heavy ion collisions.

preprint2010arXiv

Upper limit of the total cross section for the pn --> pn eta' reaction

The upper limit of the total cross section for the pn --> pn eta' reaction has been determined near the kinematical threshold in the excess energy range from 0 to 24 MeV. The measurement was performed using the COSY-11 detector setup, a deuteron cluster target, and the proton beam of COSY with a momentum of 3.35 GeV/c. The energy dependence of the upper limit of the cross section was extracted exploiting the Fermi momenta of nucleons inside the deuteron. Comparison of the determined upper limit of the ratio R_eta' = sigma(pn --> pn eta') / sigma(pp --> pp eta') with the corresponding ratio for eta-meson production does not favor the dominance of the N*(1535) resonance in the production process of the eta' meson and suggests nonidentical production mechanisms for eta and eta' mesons.

preprint2009arXiv

Invariant mass distributions for the pp to p p eta reaction at Q=10 MeV

Proton-proton and proton-eta invariant mass distributions and the total cross section for the pp to pp eta reaction have been determined near the threshold at an excess energy of Q=10 MeV. The experiment has been conducted using the COSY-11 detector setup and the cooler synchrotron COSY. The determined invariant mass spectra reveal significant enhancements in the region of low proton-proton relative momenta, similarly as observed previously at higher excess energies of Q=15.5 MeV and Q= 40MeV.

preprint2008arXiv

Dynamics of the near threshold eta meson production in proton-proton interaction

We present the results of measurements of the analysing power for the p(pol)p --> pp eta reaction at the excess energies of Q=10 and 36 MeV, and interpret these results within the framework of the meson exchange models. The determined values of the analysing power at both excess energies are consistent with zero implying that the eta meson is produced predominantly in s-wave.

preprint2008arXiv

Near threshold production of the pseudoscalar mesons at the COSY-11 facility

We summarise measurements of the COSY-11 collaboration concerning the excitation functions of the near threshold pseudoscalar meson production in the proton-proton interaction. The results are discussed in the context of the meson-nucleon and hyperon-nucleon interactions. We conclude that the $η$-proton interaction is significantly stronger than the eta'-proton interaction. Similarly, we found that the hyperon Lambda interacts with the nucleon considerably stronger than the hyperon Sigma, and that the interaction of (K-)-proton is much stronger than this of the (K+)-proton.