Source author record

M. Pandurovic

M. Pandurovic appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

GPU-based optical simulation of the DARWIN detector

Understanding propagation of scintillation light is critical for maximizing the discovery potential of next-generation liquid xenon detectors that use dual-phase time projection chamber technology. This work describes a detailed optical simulation of the DARWIN detector implemented using Chroma, a GPU-based photon tracking framework. To evaluate the framework and to explore ways of maximizing efficiency and minimizing the time of light collection, we simulate several variations of the conventional detector design. Results of these selected studies are presented. More generally, we conclude that the approach used in this work allows one to investigate alternative designs faster and in more detail than using conventional Geant4 optical simulations, making it an attractive tool to guide the development of the ultimate liquid xenon observatory.

preprint2020arXiv

Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of $^{136}$Xe

The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of $^{136}$Xe. Out of its 50$\,$t total natural xenon inventory, 40$\,$t will be the active target of a time projection chamber which thus contains about 3.6 t of $^{136}$Xe. Here, we show that its projected half-life sensitivity is $2.4\times10^{27}\,$yr, using a fiducial volume of 5t of natural xenon and 10$\,$yr of operation with a background rate of less than 0.2$~$events/(t$\cdot$yr) in the energy region of interest. This sensitivity is based on a detailed Monte Carlo simulation study of the background and event topologies in the large, homogeneous target. DARWIN will be comparable in its science reach to dedicated double beta decay experiments using xenon enriched in $^{136}$Xe.

preprint2015arXiv

Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector

Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.

preprint2014arXiv

ECFA Detector R&D Panel, Review Report

Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on the performance of BeamCal, as well as to optimise the design of both calorimeters. Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and prototypes are available. Prototypes of sensor planes fully assembled with readout electronics have been studied in electron beams.

preprint2014arXiv

Precision luminosity measurement at ILC

In these proceedings a novel approach to deal with the beam-induced effects in luminosity measurement is presented. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainties can be reduced to the permille level independently of a precision with which the beam parameters are known. Specific event selection combined with the corrective methods we introduce, leads to the systematic uncertainty from the beam-induced effects to be at a few permille level in the peak region above the 80% of the nominal centre-of-mass energies at ILC.

preprint2014arXiv

SM-like Higgs decay into two muons at 1.4 TeV CLIC

The branching fraction measurement of the SM-like Higgs boson decay into two muons at 1.4 TeV CLIC will be described in this paper contributed to the LCWS13. The study is performed in the fully simulated ILD detector concept for CLIC, taking into consideration all the relevant physics and the beam-induced backgrounds, as well as the instrumentation of the very forward region to tag the high-energy electrons. Higgs couplings are known to be sensitive to BSM physics and we prove that BR times the Higgs production cross section can be measured with approximately 35.5% statistical accuracy in four years of the CLIC operation at 1.4 TeV centre-of-mass energy with unpolarised beams. The result is preliminary as the equivalent photon approximation is not considered in the cross-section calculations. This study complements the Higgs physics program foreseen at CLIC.

preprint2013arXiv

Luminosity measurement at ILC

In this paper we describe a method of luminosity measurement at the future linear collider ILC that estimates and corrects for the impact of the dominant sources of systematic uncertainty originating from the beam-induced effects and the background from physics processes. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainty is reduced to a permille independently of the precision with which the beam parameters are known. With the specific event selection, different from the isolation cuts based on topology of the signal used at LEP, combined with the corrective methods we introduce, the overall systematic uncertainty in the peak region above 80% of the nominal center-of-mass energy meets the physics requirements to be at the few permille level at all ILC energies.

preprint2013arXiv

Physics background at ILC at 500GeV and 1TeV

Measurement of the integrated luminosity at the International Linear Collider (ILC) will be accomplished by counting the rate of small angle Bhabha scattering events. The physics requirements for ILC set the constraint on the relative precision of the luminosity measurement to be of a permille order. The required precision can be achieved by construction of a fine granulated electromagnetic calorimeter of high energy and polar angle resolution and by sufficient experimental control of numerous systematic effects. One of the leading systematic effects in luminosity measurement is the background originating from four-fermion processes, referred to as the physics background. In this paper a possible selection strategy to measure the luminosity is proposed from the perspective of optimal signal to background separation.

preprint2010arXiv

Luminosity Measurement at ILC

More than twenty institutes join the FCAL Collaboration in study of design of the very forward region of a detector for ILC and CLIC. Of particular importance is an accurate luminosity measurement to the level of 10-3, a requirement driven by the potential for precision physics at a future linear collider. In this paper, the method for luminosity measurement, requirements on luminometer and its integration in the forward region are presented. The impact of several effects contributing to the systematic uncertainty of luminosity measurement is given.