Researcher profile

M. P. Westig

M. P. Westig contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - Baseline
3works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2013arXiv

Improved Nb SIS devices for heterodyne mixers between 700 GHz and 1.3 THz with NbTiN transmission lines using a normal metal energy relaxation layer

In this paper we demonstrate experimentally the implementation of a niobium-trilayer junction with an aluminum-oxide tunnel barrier, embedded in a high-gap superconducting niobium-titanium-nitride circuit. Previously reported heating by quasiparticle trapping is removed by inserting a normal metal layer of gold between the niobium junction and the niobium-titanium-nitride layer. We analyze in dc-characterization measurements the cooling of the nonequilibrium quasiparticles in various device geometries having different gold layer thickness and shape. Our work is concluded with remarks for future heterodyne mixer experiments using our device technology.

preprint2011arXiv

Balanced superconductor-insulator-superconductor mixer on a 9~$μ$m silicon membrane

We present a 380-520 GHz balanced superconductor-insulator-superconductor (SIS) mixer on a single silicon substrate. All radio-frequency (RF) circuit components are fabricated on a $9 μ$m thick membrane. The intermediate frequency (IF) is separately amplified and combined. The balanced mixer chip, using Nb/Al/Al$_{2}$O$_{3}$/Nb SIS junctions, is mounted in a tellurium copper waveguide block at 4.2 K using Au beam lead contacts. We find uncorrected minimum receiver double-sideband noise temperatures of 70 K and a noise suppression of up to 18 dB, measured within a 440-495 GHz RF and a 4-8 GHz IF bandwidth, representing state-of-the-art device performance.

preprint2011arXiv

Hydrogen Spectroscopy with a Lamb-shift Polarimeter - An Alternative Approach Towards Anti-Hydrogen Spectroscopy Experiments

A Lamb-shift polarimeter, which has been built for a fast determination of the polarization of protons and deuterons of an atomic-beam source and which is frequently used in the ANKE experiment at COSY-Jülich, is shown to be an excellent device for atomic-spectroscopy measurements of metastable hydrogen isotopes. It is demonstrated that magnetic and electric dipole transitions in hydrogen can be measured as a function of the external magnetic field, giving access to the full Breit-Rabi diagram for the $2^2S_{1/2}$ and the $2^2P_{1/2}$ states. This will allow the study of hyperfine structure, $g$ factors and the classical Lamb shift. Although the data are not yet competitive with state-of-the-art measurements, the potential of the method is enormous, including a possible application to anti-hydrogen spectroscopy.