Source author record

M. Manfra

M. Manfra appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
1topics
3close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2013arXiv

Aharonov-Bohm effect and coherence length of charge e/4 quasiparticles at 5/2 filling factor measured in multiple small Fabry-Perot interferometers

Design of a Fabry-Perot (double point contact) interferometer to measure fractional quantum Hall effect quasiparticle charge properties, and in particular the 5/2 excitations, poses an important trade-off: the device size should be minimized to allow two path interference, since the coherence length of the quasiparticles in the correlated states are expected be limited, yet a small device promotes the dominance of Coulomb charging effects which would overwhelm the Aharonov-Bohm interference effect. In this study a series of small but different size interferometers from the same high density heterostructure wafer are examined for the presence of Coulomb effects versus Aharonov-Bohm (A-B) interference effect when operated in gate configurations that support the 5/2, 7/3, and 8/3 fractional quantum Hall effects. The device sizes vary by more than a factor of three, and over this range explicitly show specific properties of A-B interference, but not Coulomb dominated effects. Given these A-B interference results, the coherence length of the charge e/4 interference is extracted. The coherence length of non-Abelian e/4 quasiparticles is an important parameter for design and development of complex interference devices used to study and apply this exotic excitation. As in prior observations of e/4 excitations, A-B e/4 and e/2 oscillations in alternation are observed in these multiple devices. The amplitudes of the e/4 oscillations are observed to be dramatically reduced for larger area interferometers. Path-length limits are derived from interferometer areas determined directly by A-B measurements, and the attenuation lengths of the e/4 oscillations are shown to be micron to sub-micron scale. This coherence length is consistent with that of the 7/3 excitations measured here, and consistent with theoretical models.