Researcher profile

M. M. Fowler

M. M. Fowler contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - Baseline
5works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2014arXiv

Reaction-in-Flight Neutrons as a Test of Stopping Power in Degenerate Plasmas

We present the first measurements of reaction-in-flight (RIF) neutrons in an inertial confinement fusion system. The experiments were carried out at the National Ignition Facility, using both Low Foot and High Foot drives and cryogenic plastic capsules. In both cases, the high-energy RIF ($E_n>$ 15 MeV) component of the neutron spectrum was found to be about $10^{-4}$ of the total. The majority of the RIF neutrons were produced in the dense cold fuel surrounding the burning hotspot of the capsule and the data are consistent with a compressed cold fuel that is moderately to strongly coupled $(Γ\sim$0.6) and electron degenerate $(θ_\mathrm{Fermi}/θ_e\sim$4). The production of RIF neutrons is controlled by the stopping power in the plasma. Thus, the current RIF measurements provide a unique test of stopping power models in an experimentally unexplored plasma regime. We find that the measured RIF data strongly constrain stopping models in warm dense plasma conditions and some models are ruled out by our analysis of these experiments.

preprint2013arXiv

A 4p BaF2 detector for (n,g) cross section measurements at a spallation neutron source

The quest for improved neutron capture cross sections for advanced reactor concepts, transmutation of radioactive wastes as well as for astrophysical scenarios of neutron capture nucleosynthesis has motivated new experimental efforts based on modern techniques. Recent measurements in the keV region have shown that a 4p BaF2 detector represents an accurate and versatile instrument for such studies. The present work deals with the potential of such a 4p BaF2 detector in combination with spallation neutron sources, which offer large neutron fluxes over a wide energy range. Detailed Monte Carlo simulations with the GEANT package have been performed to investigate the critical backgrounds at a spallation facility, to optimize the detector design, and to discuss alternative solutions.

preprint2011arXiv

Measurement of the $ν_e$ and Total $^{8}$B Solar Neutrino Fluxes with the Sudbury Neutrino Observatory Phase-III Data Set

This paper details the solar neutrino analysis of the 385.17-day Phase-III data set acquired by the Sudbury Neutrino Observatory (SNO). An array of $^3$He proportional counters was installed in the heavy-water target to measure precisely the rate of neutrino-deuteron neutral-current interactions. This technique to determine the total active $^8$B solar neutrino flux was largely independent of the methods employed in previous phases. The total flux of active neutrinos was measured to be $5.54^{+0.33}_{-0.31}(stat.)^{+0.36}_{-0.34}(syst.)\times 10^{6}$ cm$^{-2}$ s$^{-1}$, consistent with previous measurements and standard solar models. A global analysis of solar and reactor neutrino mixing parameters yielded the best-fit values of $Δm^2 = 7.59^{+0.19}_{-0.21}\times 10^{-5}{eV}^2$ and $θ= 34.4^{+1.3}_{-1.2}$ degrees.

preprint2007arXiv

An array of low-background $^3$He proportional counters for the Sudbury Neutrino Observatory

An array of Neutral-Current Detectors (NCDs) has been built in order to make a unique measurement of the total active flux of solar neutrinos in the Sudbury Neutrino Observatory (SNO). Data in the third phase of the SNO experiment were collected between November 2004 and November 2006, after the NCD array was added to improve the neutral-current sensitivity of the SNO detector. This array consisted of 36 strings of proportional counters filled with a mixture of $^3$He and CF$_4$ gas capable of detecting the neutrons liberated by the neutrino-deuteron neutral current reaction in the D$_2$O, and four strings filled with a mixture of $^4$He and CF$_4$ gas for background measurements. The proportional counter diameter is 5 cm. The total deployed array length was 398 m. The SNO NCD array is the lowest-radioactivity large array of proportional counters ever produced. This article describes the design, construction, deployment, and characterization of the NCD array, discusses the electronics and data acquisition system, and considers event signatures and backgrounds.

preprint2004arXiv

GEANT simulations of neutron capture experiments with a 4p BaF2 detector

The goal of this research project is to give quantitative information useful for the design of a g-ray detector to investigate neutron capture (n, g) reactions on radioactive nuclei at the Manuel Lujan Jr. Neutron Scattering Center (MLNSC) moderated neutron source at LANSCE. Data for neutron energies from thermal up to approximately 500 keV are desired. The radioactive nuclei can have half-lives as short as a few months. With the sample sizes foreseen, typically 1 mg, the radioactive decay rate can exceed tens of Curies (Ci).