Source author record

M. Hollister

M. Hollister appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Cryogenic User Facilities for R&D on Noble Liquid Detectors and Low Temperature Devices

Cryogenic test facilities are critical infrastructure for physics experiments in a variety of fields, perhaps most notably for particle detection with noble liquid detectors, low-temperature device development, and quantum information research. However, considerable investment and technical knowledge are required to construct and operate such facilities. This white paper discusses proposals for user facilities aimed at broadening the availability of testing capabilities for the scientific community.

preprint2021arXiv

SPT-SLIM: A Line Intensity Mapping Pathfinder for the South Pole Telescope

The South Pole Telescope Summertime Line Intensity Mapper (SPT-SLIM) is a pathfinder experiment that will demonstrate the use of on-chip filter-bank spectrometers for mm-wave line intensity mapping (LIM). The SPT-SLIM focal plane consists of 18 dual-polarization R=300 filter-bank spectrometers covering 120-180 GHz, coupled to aluminum kinetic inductance detectors. A compact cryostat holds the detectors at 100 mK and performs observations without removing the SPT-3G receiver. SPT-SLIM will be deployed to the 10-m South Pole Telescope for observations during the 2023-24 austral summer. We discuss the overall instrument design, expected detector performance and sensitivity to the LIM signal from CO at 0.5 < z < 2. The technology and observational techniques demonstrated by SPT-SLIM will enable next-generation LIM experiments that constrain cosmology beyond the redshift reach of galaxy surveys.

preprint2015arXiv

Low Noise Titanium Nitride KIDs for SuperSpec: A Millimeter-Wave On-Chip Spectrometer

SuperSpec is a novel on-chip spectrometer we are developing for multi-object, moderate resolution (R = 100 - 500), large bandwidth (~1.65:1) submillimeter and millimeter survey spectroscopy of high-redshift galaxies. The spectrometer employs a filter bank architecture, and consists of a series of half-wave resonators formed by lithographically-patterned superconducting transmission lines. The signal power admitted by each resonator is detected by a lumped element titanium nitride (TiN) kinetic inductance detector (KID) operating at 100 - 200 MHz. We have tested a new prototype device that achieves the targeted R = 100 resolving power, and has better detector sensitivity and optical efficiency than previous devices. We employ a new method for measuring photon noise using both coherent and thermal sources of radiation to cleanly separate the contributions of shot and wave noise. We report an upper limit to the detector NEP of $1.4\times10^{-17}$ W Hz$^{-1/2}$, within 10% of the photon noise limited NEP for a ground-based R=100 spectrometer.

preprint2015arXiv

Status of SuperSpec: A Broadband, On-Chip Millimeter-Wave Spectrometer

SuperSpec is a novel on-chip spectrometer we are developing for multi-object, moderate resolution (R = 100 - 500), large bandwidth (~1.65:1) submillimeter and millimeter survey spectroscopy of high-redshift galaxies. The spectrometer employs a filter bank architecture, and consists of a series of half-wave resonators formed by lithographically-patterned superconducting transmission lines. The signal power admitted by each resonator is detected by a lumped element titanium nitride (TiN) kinetic inductance detector (KID) operating at 100-200 MHz. We have tested a new prototype device that is more sensitive than previous devices, and easier to fabricate. We present a characterization of a representative R=282 channel at f = 236 GHz, including measurements of the spectrometer detection efficiency, the detector responsivity over a large range of optical loading, and the full system optical efficiency. We outline future improvements to the current system that we expect will enable construction of a photon-noise-limited R=100 filter bank, appropriate for a line intensity mapping experiment targeting the [CII] 158 micron transition during the Epoch of Reionization