Source author record

M. Hartl

M. Hartl appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

11works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2022arXiv

First Light for GRAVITY Wide: Large Separation Fringe Tracking for the Very Large Telescope Interferometer

GRAVITY+ is the upgrade of GRAVITY and the Very Large Telescope Interferometer (VLTI) with wide-separation fringe tracking, new adaptive optics, and laser guide stars on all four 8~m Unit Telescopes (UTs), for ever fainter, all-sky, high contrast, milliarcsecond interferometry. Here we present the design and first results of the first phase of GRAVITY+, called GRAVITY Wide. GRAVITY Wide combines the dual-beam capabilities of the VLTI and the GRAVITY instrument to increase the maximum separation between the science target and the reference star from 2 arcseconds with the 8 m UTs up to several 10 arcseconds, limited only by the Earth's turbulent atmosphere. This increases the sky-coverage of GRAVITY by two orders of magnitude, opening up milliarcsecond resolution observations of faint objects, and in particular the extragalactic sky. The first observations in 2019 - 2022 include first infrared interferometry of two redshift $z\sim2$ quasars, interferometric imaging on the binary system HD 105913A, and repeated observations of multiple star systems in the Orion Trapezium Cluster. We find the coherence loss between the science object and fringe-tracking reference star well described by the turbulence of the Earth's atmosphere. We confirm that the larger apertures of the UTs result in higher visibilities for a given separation due to larger overlap of the projected pupils on sky and give predictions for visibility loss as a function of separation to be used for future planning.

preprint2022arXiv

GRAVITY faint: reducing noise sources in GRAVITY$^+$ with a fast metrology attenuation system

With the upgrade from GRAVITY to GRAVITY$^+$ the instrument will evolve into an all-sky interferometer that can observe faint targets, such as high redshift AGN. Observing the faintest targets requires reducing the noise sources in GRAVITY as much as possible. The dominant noise source, especially in the blue part of the spectrum, is the backscattering of the metrology laser light onto the detector. To reduce this noise we introduce two new metrology modes. With a combination of small hardware changes and software adaptations, we can dim the metrology laser during the observation without losing the phase referencing. For single beam targets, we can even turn off the metrology laser for the maximum SNR on the detector. These changes lead to an SNR improvement of over a factor of two averaged over the whole spectrum and up to a factor of eight in the part of the spectrum currently dominated by laser noise.

preprint2022arXiv

The MICADO Atmospheric Dispersion Corrector: Optomechanical design, expected performance and calibration techniques

The differential refraction of light passing through the atmosphere can have a severe impact on image quality if no atmospheric dispersion corrector (ADC) is used. For the Extremely Large Telescope (ELT) this holds true well into the infrared. MICADO, the near-infrared imaging camera for the ELT, will employ a cryogenic ADC consisting of two counter-rotating Amici prisms with diameters of 125 mm. The mechanism will reduce the atmospheric dispersion to below 2.5 milli arcseconds (mas), with a set goal of 1 mas. In this report, we provide an overview of the current status of the ADC in development for MICADO. We summarise the optomechanical design and discuss how the cryogenic environment impacts the performance. We will also discuss our plan to use a diffraction mask in the cold pupil to calibrate and validate the performance once the instrument is fully integrated.

preprint2021arXiv

Constructed wetlands operated as bioelectrochemical systems for the removal of organic micropollutants

The removal of organic micropollutants (OMPs) has been investigated in constructed wetlands (CWs) operated as bioelectrochemical systems (BES). The operation of CWs as BES (CW-BES), either in the form of microbial fuel cells (MFC) or microbial electrolysis cells (MEC), has only been investigated in recent years. The presented experiment used CW meso-scale systems applying a realistic horizontal flow regime and continuous feeding of real urban wastewater spiked with four OMPs (pharmaceuticals), namely carbamazepine (CBZ), diclofenac (DCF), ibuprofen (IBU) and naproxen (NPX). The study evaluated the removal efficiency of conventional CW systems (CW-control) as well as CW systems operated as closed-circuit MFCs (CW-MFCs) and MECs (CW-MECs). Although a few positive trends were identified for the CW-BES compared to the CW-control (higher average CBZ, DCF and NPX removal by 10-17% in CW-MEC and 5% in CW-MFC), these proved to be not statistically significantly different. Mesoscale experiments with real wastewater could thus not confirm earlier positive effects of CW-BES found under strictly controlled laboratory conditions with synthetic wastewaters.

preprint2020arXiv

MFC-based biosensor for domestic wastewater COD assessment in constructed wetlands

In the context of natural-based wastewater treatment technologies (such as constructed wetlands - CW) the use of a low-cost, continuous-like biosensor tool for the assessment of operational conditions is of key importance for plant management optimization. The objective of the present study was to assess the potential use of constructed wetland microbial fuel cells (CW-MFC) as a domestic wastewater COD assessment tool. For the purpose of this work four lab-scale CW-MFCs were set up and fed with pre-settled domestic wastewater at different COD concentrations. Under laboratory conditions two different anodic materials were tested (graphite rods and gravel). Furthermore, a pilot-plant based experiment was also conducted to confirm the findings previously recorded for lab-scale experiments. Results showed that in spite of the low coulombic efficiencies recorded, either gravel or graphite-based anodes were suitable for the purposes of domestic wastewater COD assessment. Significant linear relationships could be established between inlet COD concentrations and CW-MFC Ecell whenever contact time was above 10 hours. Results also showed that the accuracy of the CW-MFC was greatly compromised after several weeks of operation. Pilot experiments showed that CW-MFC presents a good bio-indication response between week 3 and 7 of operation (equivalent to an accumulated organic loading between 100 and 200 g COD/m2, respectively). Main conclusion of this work is that of CW-MFC could be used as an "alarm-tool" for qualitative continuous influent water quality assessment rather than a precise COD assessment tool due to a loss of precision after several weeks of operation.

preprint2016arXiv

Making SPIFFI SPIFFIER: Upgrade of the SPIFFI instrument for use in ERIS and performance analysis from re-commissioning

SPIFFI is an AO-fed integral field spectrograph operating as part of SINFONI on the VLT, which will be upgraded and reused as SPIFFIER in the new VLT instrument ERIS. In January 2016, we used new technology developments to perform an early upgrade to optical subsystems in the SPIFFI instrument so ongoing scientific programs can make use of enhanced performance before ERIS arrives in 2020. We report on the upgraded components and the performance of SPIFFI after the upgrade, including gains in throughput and spatial and spectral resolution. We show results from re-commissioning, highlighting the potential for scientific programs to use the capabilities of the upgraded SPIFFI. Finally, we discuss the additional upgrades for SPIFFIER which will be implemented before it is integrated into ERIS.

preprint2016arXiv

MICADO: first light imager for the E-ELT

MICADO will equip the E-ELT with a first light capability for diffraction limited imaging at near-infrared wavelengths. The instrument's observing modes focus on various flavours of imaging, including astrometric, high contrast, and time resolved. There is also a single object spectroscopic mode optimised for wavelength coverage at moderately high resolution. This contribution provides an overview of the key functionality of the instrument, outlining the scientific rationale for its observing modes. The interface between MICADO and the adaptive optics system MAORY that feeds it is summarised. The design of the instrument is discussed, focussing on the optics and mechanisms inside the cryostat, together with a brief overview of the other key sub-systems.

preprint2014arXiv

An aperture masking mode for the MICADO instrument

MICADO is a near-IR camera for the Europea ELT, featuring an extended field (75" diameter) for imaging, and also spectrographic and high contrast imaging capabilities. It has been chosen by ESO as one of the two first-light instruments. Although it is ultimately aimed at being fed by the MCAO module called MAORY, MICADO will come with an internal SCAO system that will be complementary to it and will deliver a high performance on axis correction, suitable for coronagraphic and pupil masking applications. The basis of the pupil masking approach is to ensure the stability of the optical transfer function, even in the case of residual errors after AO correction (due to non common path errors and quasi-static aberrations). Preliminary designs of pupil masks are presented. Trade-offs and technical choices, especially regarding redundancy and pupil tracking, are explained.

preprint2013arXiv

The Upscattering of Ultracold Neutrons from the polymer $[C_6 H_{12}]_n$

It is generally accepted that the main cause of ultracold neutron (UCN) losses in storage traps is the upscattering to the thermal energy range by hydrogen adsorbed on the surface of the trap walls. However, the data on which this conclusion is based are poor and contradictory. Here, we report a measurement, performed at the Los Alamos National Laboratory UCN source, of the average energy of the flux of upscattered neutrons after the interaction of UCN with hydrogen bound in semicrystalline polymer PMP (tradename TPX), [C$_{6}$H$_{12}$]$_n$. Our analysis, performed with the MCNP code based on the application of the neutron scattering law to UCN upscattered by bound hydrogen in semicrystalline polyethylene, [C$_{2}$H$_{4}$]$_n$, leads us to a flux average energy value of 26$\pm3$ meV in contradiction with previously reported experimental values of 10 to 13 meV and in agreement with the theoretical models of neutron heating implemented in the MCNP code.

preprint2008arXiv

Quadratic maps between modules

We introduce a notion of $R$-quadratic maps between modules over a commutative ring $R$ which generalizes several classical notions arising in linear algebra and group theory. On a given module $M$ such maps are represented by $R$-linear maps on a certain module $P^2_R(M)$. The structure of this module is described in term of the symmetric tensor square $Sym^2_R(M)$, the degree 2 component $Γ^2_R(M)$ of the divided power algebra over $M$, and the ideal $I_2$ of $R$ generated by the elements $r^2-r$, $r\in R$. The latter is shown to represent quadratic derivations on $R$ which arise in the theory of modules over square rings. This allows to extend the classical notion of nilpotent $R$-group of class 2 with coefficients in a 2-binomial ring $R$ to any ring $R$. We provide a functorial presentation of $I_2$ and several exact sequences embedding the modules $P^2_R(M)$ and $Γ^2_R(M)$.