Source author record

M. H. Moulai

M. H. Moulai appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Combining Sterile Neutrino Fits to Short Baseline Data with IceCube Data

Recent global fits to short-baseline neutrino oscillation data have been performed finding preference for a sterile neutrino solution (3+1) over null. In the most recent iteration, it was pointed out that an unstable sterile neutrino (3+1+decay) may be a better description of the data. This is due to the fact that this model significantly reduces the tension between appearance and disappearance datasets. In this work, we add a one-year IceCube dataset to the global fit obtaining new results for the standard 3+1 and 3+1+decay sterile neutrino scenarios. We find that the 3+1+decay model provides a better fit than the 3+1, even in the presence of IceCube, with reduced appearance to disappearance tension. The 3+1+decay model is a 5.4$σ$ improvement over the null hypothesis and a 2.8$σ$ improvement over the standard 3+1 model.

preprint2020arXiv

Pulse Shape Particle Identification by a Single Large Hemispherical Photo-Multiplier Tube

In neutrino experiments, hemispherical photomultiplier tubes (PMTs) are often used to cover large surfaces or volumes to maximize the photocathode coverage with a minimum number of channels. Instrumentation is often coarse, and neutrino event reconstruction and particle identification (PID) is usually done through the morphology of PMT hits. In future neutrino experiments, it may be desirable to perform PID from a few hits, or even a single hit, by utilizing pulse shape information. In this report, we study the principle of pulse shape PID using a single 10-inch hemispherical PMT in a spherical glass housing for future neutrino telescopes. We use the Fermilab Test Beam Facility (FTBF) MTest beamline to demonstrate that with pulse shape PID, statistical separation is possible to distinguish 2 GeV electrons from 8 GeV pions, where the total charge deposition is ~20 PE in our setup. Such techniques can be applied to future neutrino telescopes focusing on low energy physics, including the IceCube-Upgrade.

preprint2015arXiv

Demonstrating a directional detector based on neon for characterizing high energy neutrons

MITPC is a gas-based time projection chamber used for detecting fast, MeV-scale neutrons. The standard version of the detector relies on a mixture of 600~torr gas composed of 87.5% $^4$He and 12.5% CF$_4$ for precisely measuring the energy and direction of neutron-induced nuclear recoils. We describe studies performed with a prototype detector investigating the use of Ne, as a replacement for $^4$He, in the gas mixture. Our discussion focuses on the advantages of Ne as the fast neutron target for high energy neutron events ($\lesssim$100 MeV) and a demonstration that the mixture will be effective for this event class. We find that the achievable gain and transverse diffusion of drifting electrons in the Ne mixture are acceptable and that the detector uptime lost due to voltage breakdowns in the amplification plane is negligible, compared to $\sim$ 20% with the $^4$He mixture.

preprint2015arXiv

IsoDAR@KamLAND: A Conceptual Design Report for the Technical Facility

This conceptual design report describes the technical facility for the IsoDAR electron-antineutrino source at KamLAND. The IsoDAR source will allow an impressive program of neutrino oscillation and electroweak physics to be performed at KamLAND. This report provides information on the physics case, the conceptual design for the subsystems, alternative designs considered, specifics of installation at KamLAND, and identified needs for future development. We discuss the risks we have identified and our approach to mitigating those risks with this design. A substantial portion of the conceptual design is based on three years of experimental efforts and on industry experience. This report also includes information on the conventional facilities.