Researcher profile

M. Grandi

M. Grandi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2010arXiv

NEUCAL, an innovative neutron detector for e/h discrimination: testbeam results

An excellent hadron to electron discrimination is a crucial aspect of calorimeter-based experiments in astroparticle physics. Standard discrimination techniques require full shower development and fine granularity but in space detectors severe limitations exist due to constraints on dimensions, weight and power consumption. A possible approach is to exploit the different neutron yield of electromagnetic and hadronic showers. NEUCAL is a light and compact innovative neutron detector, to be used as an auxiliary complement of electromagnetic calorimeters. This new approach to neutron counting relies on scintillation detectors which are sensitive to the moderation phase of the neutron component. The NEUCAL prototype has been placed after a conventional calorimeter and tested with high energy beams of pions and positrons. The comparison of experimental data with a detailed Geant4 simulation and the encouraging results obtained are presented.

preprint2010arXiv

NEUCAL: a prototype detector for electron/hadron discrimination through neutron measurement

NEUCAL is a neutron detector which is currently under study to be used as a sub-detector complementing electromagnetic (e.m.) calorimeters for electron/hadron discrimination in cosmic rays at high energy. Its aim is to reveal the different yield of neutron production in e.m. and hadronic showers, not only by counting signals due to their absorption in some sensible detector after passive moderation, but also looking for signals produced during the moderation phase. The basic idea and a test of a prototype detector are discussed in this paper. A first preliminary comparison of experimental data with simulation is also shown.

preprint2010arXiv

UVB radiation induced effects on cells studied by FTIR spectroscopy

We have made a preliminary analysis of the results about the eVects on tumoral cell line (lymphoid T cell line Jurkat) induced by UVB radiation (dose of 310 mJ/cm^2) with and without a vegetable mixture. In the present study, we have used two techniques: Fourier transform infrared spectroscopy (FTIR) and flow cytometry. FTIR spectroscopy has the potential to provide the identiWcation of the vibrational modes of some of the major compounds (lipid, proteins and nucleic acids) without being invasive in the biomaterials. The second technique has allowed us to perform measurements of cytotoxicity and to assess the percentage of apoptosis. We already studied the induction of apoptotic process in the same cell line by UVB radiation; in particular, we looked for correspondences and correlations between FTIR spetroscopy and flow cytometry data finding three highly probable spectroscopic markers of apoptosis (Pozzi et al. in Radiat Res 168:698-705, 2007). In the present work, the results have shown significant changes in the absorbance and spectral pattern in the wavenumber protein and nucleic acids regions after the treatments.

preprint2005arXiv

Spatial Resolution of Double-Sided Silicon Microstrip Detectors for the PAMELA Apparatus

The PAMELA apparatus has been assembled and it is ready to be launched in a satellite mission to study mainly the antiparticle component of cosmic rays. In this paper the performances obtained for the silicon microstrip detectors used in the magnetic spectrometer are presented. This subdetector reconstructs the curvature of a charged particle in the magnetic field produced by a permanent magnet and consequently determines momentum and charge sign, thanks to a very good accuracy in the position measurements (better than 3 um in the bending coordinate). A complete simulation of the silicon microstrip detectors has been developed in order to investigate in great detail the sensor's characteristics. Simulated events have been then compared with data gathered from minimum ionizing particle (MIP) beams during the last years in order to tune free parameters of the simulation. Finally some either widely used or original position finding algorithms, designed for such kind of detectors, have been applied to events with different incidence angles. As a result of the analysis, a method of impact point reconstruction can be chosen, depending on both the particle's incidence angle and the cluster multiplicity, so as to maximize the capability of the spectrometer in antiparticle tagging.