Researcher profile

M. González

M. González contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
10works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2022arXiv

ALMA-IMF III -- Investigating the origin of stellar masses: Top-heavy core mass function in the W43-MM2&MM3 mini-starburst

The ALMA-IMF Large Program observed the W43-MM2-MM3 ridge, whose 1.3mm and 3mm ALMA 12m array continuum images reach a 2500au spatial resolution. We used both the best-sensitivity and the line-free ALMA-IMF images, reduced the noise with the multi-resolution segmentation technique MnGSeg, and derived the most complete and most robust core catalog possible. Using two different extraction software packages, getsf and GExt2D, we identified 200 compact sources, whose 100 common sources have on average fluxes consistent to within 30%. We filtered sources with non-negligible free-free contamination and corrected fluxes from line contamination, resulting in a W43-MM2-MM3 catalog of 205 getsf cores. With a median deconvolved FWHM size of 3400au, core masses range from 0.1Msun to 70Msun and the getsf catalog is 90% complete down to 0.8Msun. The high-mass end of the core mass function (CMF) of W43-MM2-MM3 is top-heavy compared to the canonical IMF. Fitting the cumulative CMF with a single power law of the form N(>logM)\propto M^a, we measured a=-0.95\pm0.04, compared to the canonical a=-1.35 Salpeter IMF slope. The slope of the CMF is robust with respect to map processing, extraction software package, and reasonable variations in the assumptions taken to estimate core masses. We explore several assumptions on how cores transfer their mass to stars and sub-fragment to predict the IMF resulting from the W43-MM2-MM3 CMF. In stark contrast to the commonly accepted paradigm, our result argues against the universality of the CMF shape. More robust functions of the star-formation efficiency and core sub-fragmentation are required to better predict the resulting IMF, here suggested to remain top-heavy at the end of the star-formation phase. If confirmed, the IMFs emerging from starburst events could inherit their top-heavy shape from their parental CMFs, challenging the IMF universality.

preprint2022arXiv

QUBIC II: Spectro-Polarimetry with Bolometric Interferometry

Bolometric interferometry is a novel technique that has the ability to perform spectral imaging. A bolometric interferometer observes the sky in a wide frequency band and can reconstruct sky maps in several sub-bands within the physical band in post-processing of the data. This provides a powerful spectral method to discriminate between the cosmic microwave background (CMB) and astrophysical foregrounds. In this paper, the methodology is illustrated with examples based on the Q \& U Bolometric Interferometer for Cosmology (QUBIC) which is a ground-based instrument designed to measure the B-mode polarization of the sky at millimeter wavelengths. We consider the specific cases of point source reconstruction and Galactic dust mapping and we characterize the point spread function as a function of frequency. We study the noise properties of spectral imaging, especially the correlations between sub-bands, using end-to-end simulations together with a fast noise simulator. We conclude showing that spectral imaging performance are nearly optimal up to five sub-bands in the case of QUBIC.

preprint2022arXiv

QUBIC III: Laboratory Characterization

A prototype version of the Q & U Bolometric Interferometer for Cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology in Paris. We report the results of this Technological Demonstrator which successfully shows the feasibility of the principle of Bolometric Interferometry. Characterization of QUBIC includes the measurement of the synthesized beam, the measurement of interference fringes, and the measurement of polarization performance. A modulated and frequency tunable millimetre-wave source in the telescope far-field is used to simulate a point source. The QUBIC pointing is scanned across the point source to produce beam maps. Polarization modulation is measured using a rotating Half Wave Plate. The measured beam matches well to the theoretical simulations and gives QUBIC the ability to do spectro imaging. The polarization performance is excellent with less than 0.5\% cross-polarization rejection. QUBIC is ready for deployment on the high altitude site at Alto Chorillo, Argentina to begin scientific operations.

preprint2022arXiv

QUBIC VII: The feedhorn-switch system of the technological demonstrator

We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration. We manufactured the horns in aluminum platelets milled by photo-chemical etching and mechanically tightened with screws. The switches are based on steel blades that open and close the wave-guide between the back-to-back horns and are operated by miniaturized electromagnets. We also show the current development status of the feedhorn-switch system for the QUBIC full instrument, based on an array of 400 horn-switch assemblies.

preprint2021arXiv

ALMA-IMF I -- Investigating the origin of stellar masses: Introduction to the Large Program and first results

The ALMA-IMF Large Program imaged a total noncontiguous area of 53pc2, covering 15 extreme, nearby protoclusters of the Milky Way. They were selected to span relevant early protocluster evolutionary stages. Our 1.3mm and 3mm observations provide continuum images that are homogeneously sensitive to point-like cores with masses of 0.2 and 0.6Msun, respectively, with a matched spatial resolution of 2000au. We also detect lines that probe the protocluster structure, kinematics, chemistry, and feedback over scales from clouds to filaments to cores. We classify ALMA-IMF protoclusters as Young, Intermediate, or Evolved based on the amount of dense gas in the cloud that has potentially been impacted by HII regions. The ALMA-IMF catalog contains 700 cores that span a mass range of 0.15-250Msun at a typical size of 2100au. We show that this core sample has no significant distance bias and can be used to build core mass functions at similar physical scales. Significant gas motions, which we highlight here in the G353.41 region, are traced down to core scales and can be used to look for inflowing gas streamers and to quantify the impact of the possible associated core mass growth on the shape of the CMF with time. Our first analysis does not reveal any significant evolution of the matter concentration from clouds to cores or from the youngest to more evolved protoclusters, indicating that cloud dynamical evolution and stellar feedback have for the moment only had a slight effect on the structure of high-density gas in our sample. Furthermore, the first-look analysis of the line richness toward bright cores indicates that the survey encompasses several tens of hot cores, of which we highlight the most massive in the G351.77 cloud. Their homogeneous characterization can be used to constrain the emerging molecular complexity in protostars of high to intermediate masses.

preprint2021arXiv

QUBIC I: Overview and ScienceProgram

The Q $\&$ U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Background (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical foregrounds which can only be controlled through multichroic observations. QUBIC is designed to address these observational issues with a novel approach that combines the advantages of interferometry in terms of control of instrumental systematic effects with those of bolometric detectors in terms of wide-band, background-limited sensitivity. The QUBIC synthesized beam has a frequency-dependent shape that results in the ability to produce maps of the CMB polarization in multiple sub-bands within the two physical bands of the instrument (150 and 220 GHz). These features make QUBIC complementary to other instruments and makes it particularly well suited to characterize and remove Galactic foreground contamination. In this article, first of a series of eight, we give an overview of the QUBIC instrument design, the main results of the calibration campaign, and present the scientific program of QUBIC including not only the measurement of primordial B-modes, but also the measurement of Galactic foregrounds. We give forecasts for typical observations and measurements: with three years of integration on the sky and assuming perfect foreground removal as well as stable atmospheric conditions from our site in Argentina, our simulations show that we can achieve a statistical sensitivity to the effective tensor-to-scalar ratio (including primordial and foreground B-modes) $σ(r)=0.015$.

preprint2021arXiv

QUBIC V: Cryogenic system design and performance

Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the mapping speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interferometer for Cosmology) experiment: we describe its design, fabrication, experimental optimization and validation in the Technological Demonstrator configuration. The QUBIC cryogenic system is based on a large volume cryostat, using two pulse-tube refrigerators to cool at ~3K a large (~1 m^3) volume, heavy (~165kg) instrument, including the cryogenic polarization modulator, the corrugated feedhorns array, and the lower temperature stages; a 4He evaporator cooling at ~1K the interferometer beam combiner; a 3He evaporator cooling at ~0.3K the focal-plane detector arrays. The cryogenic system has been tested and validated for more than 6 months of continuous operation. The detector arrays have reached a stable operating temperature of 0.33K, while the polarization modulator has been operated from a ~10K base temperature. The system has been tilted to cover the boresight elevation range 20 deg -90 deg without significant temperature variations. The instrument is now ready for deployment to the high Argentinean Andes.

preprint2020arXiv

A high-performance and portable asymptotic preserving radiation hydrodynamics code with the M1 model

Aims. We present a new radiation hydrodynamics code, called "ARK-RT" which uses a two-moment model with the M1 closure relation for radiative transfer. This code aims at being ready for high-performance computing, on exascale architectures. Methods. The two-moment model is solved using a finite volume scheme. The scheme is asymptotic preserving to capture accurately both optically thick and thin regimes. We also propose a well-balanced discretization of the radiative flux source term able to capture constant flux steady states with discontinuities in opacity. We use the library Trilinos for linear algebra and the package Kokkos allows us to reach high-performance computing and portability across different architectures, such as multi-core, many-core, and GP-GPU. Results. ARK-RT is able to reproduce standard tests in both free-streaming and diffusive limits, including purely radiative tests and radiation hydrodynamics ones. Using a time-implicit solver is profitable as soon as the time step given by the hydrodynamics is 50-100 times larger than the explicit time step for radiative transfer, depending on the preconditioner and the architecture. Albeit more work is needed to ensure stability in all circumstances. Using ARK-RT, we study the propagation of an ionization front in convective dense cores. We show that the ionization front is strongly stable against perturbations even with destabilizing convective motions. As a result, the presence of instabilities should be interpreted with caution. Overall, ARK-RT is well-suited to study many astrophysical problems involving convection and radiative transfer such as the dynamics of H ii regions in massive pre-stellar dense cores and future applications could include planetary atmospheres.

preprint2020arXiv

A new hybrid radiative transfer method for massive star formation

Frequency-dependent/hybrid approaches for stellar irradiation are of primary importance in numerical simulations of massive star formation. We seek to compare outflow and accretion mechanisms in star formation simulations. We investigate the accuracy of a hybrid radiative transfer method using the gray M1 closure relation for proto-stellar irradiation and gray flux-limited diffusion (FLD) for photons emitted everywhere else. We have coupled the FLD module of the adaptive-mesh refinement code Ramses with Ramses-RT, which is based on the M1 closure relation. Our hybrid (M1+FLD) method takes an average opacity at the stellar temperature for the M1 module, instead of the local environmental radiation field. We have tested this approach in radiative transfer tests of disks irradiated by a star for three levels of optical thickness and compared the temperature structure with RADMC-3D and MCFOST. We applied it to a radiation-hydrodynamical simulation of massive star formation. Our tests validate our hybrid approach for determining the temperature structure of an irradiated disk in the optically-thin and moderately optically-thick regimes and the most optically-thick test shows the limitation of our approach. The optically-thick setups highlight the ability of the hybrid method to partially capture the self-shielding in the disk while the FLD cannot. The radiative acceleration is 100 times greater with the hybrid method. It consistently leads to about +50% more extended and wider-angle radiative outflows in the massive star formation simulation. We obtain a $17.6 M_\odot$ at $t{\simeq}0.7 τ_\mathrm{ff}$, while the accretion phase is ongoing. Finally, despite the use of refinement to resolve the radiative cavities, no Rayleigh-Taylor instability appears in our simulations, and we justify their absence by physical arguments based on the entropy gradient. (abridged)

preprint2020arXiv

QUBIC VI: cryogenic half wave plate rotator, design and performances

Inflation Gravity Waves B-Modes polarization detection is the ultimate goal of modern large angular scale cosmic microwave background (CMB) experiments around the world. A big effort is undergoing with the deployment of many ground-based, balloon-borne and satellite experiments using different methods to separate this faint polarized component from the incoming radiation. One of the largely used technique is the Stokes Polarimetry that uses a rotating half-wave plate (HWP) and a linear polarizer to separate and modulate the polarization components with low residual cross-polarization. This paper describes the QUBIC Stokes Polarimeter highlighting its design features and its performances. A common systematic with these devices is the generation of large spurious signals synchronous with the rotation and proportional to the emissivity of the optical elements. A key feature of the QUBIC Stokes Polarimeter is to operate at cryogenic temperature in order to minimize this unwanted component. Moving efficiently this large optical element at low temperature constitutes a big engineering challenge in order to reduce friction power dissipation. Big attention has been given during the designing phase to minimize the differential thermal contractions between parts. The rotation is driven by a stepper motor placed outside the cryostat to avoid thermal load dissipation at cryogenic temperature. The tests and the results presented in this work show that the QUBIC polarimeter can easily achieve a precision below 0.1° in positioning simply using the stepper motor precision and the optical absolute encoder. The rotation induces only few mK of extra power load on the second cryogenic stage (~ 8 K).