Source author record

M. Girolami

M. Girolami appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Diamond-based Detection Systems for Accurate Pulsed X-rays Diagnostics in Radiotherapy

The widespread diffusion of precision radiotherapy techniques, geared toward the release of larger dose gradients in shorter time frames, is leading to new challenges in dosimetry. Accurate dose measurements are essential to check for beam anomalies and inaccuracies to ensure treatment efficacy and patient safety during radiotherapy. This work describes the main features of a diamond dosimeter coupled to an extremely compact front-end electronics. The detection system was tested under the X-ray pulses generated by a medical LINAC for both the 6 MV and the 18 MV accelerating voltages. Located in the LINAC's bunker, it eliminates the need for a long cable connection between the detector and the electronics, detrimental for the system response speed. Signal acquisition was performed synchronously with the impinging X-ray pulses with a sampling period as low as 20 us, allowing for a real-time beam monitoring. The dosimeter demonstrated a very good stability despite the high value of the absorbed dose during the performed experiments (about 100 Gy). The measured dose-per-pulse values of 278 uGy and 556 uGy at 6 MV and 18 MV, respectively, are in excellent agreement with the nominal values expected for the LINAC apparatus used for the tests. In addition to single-pulse measurements, fundamental for dynamic radiotherapy, the proposed system also allows for the calculation of both the total collected charge and the photocurrent generated by the detector. In this regards, despite the compactness, it demonstrates its effectiveness as a tool for source diagnostics in terms of both beam intensity and emission timing.

preprint2013arXiv

Probabilistic prediction of neurological disorders with a statistical assessment of neuroimaging data modalities

For many neurological disorders, prediction of disease state is an important clinical aim. Neuroimaging provides detailed information about brain structure and function from which such predictions may be statistically derived. A multinomial logit model with Gaussian process priors is proposed to: (i) predict disease state based on whole-brain neuroimaging data and (ii) analyze the relative informativeness of different image modalities and brain regions. Advanced Markov chain Monte Carlo methods are employed to perform posterior inference over the model. This paper reports a statistical assessment of multiple neuroimaging modalities applied to the discrimination of three Parkinsonian neurological disorders from one another and healthy controls, showing promising predictive performance of disease states when compared to nonprobabilistic classifiers based on multiple modalities. The statistical analysis also quantifies the relative importance of different neuroimaging measures and brain regions in discriminating between these diseases and suggests that for prediction there is little benefit in acquiring multiple neuroimaging sequences. Finally, the predictive capability of different brain regions is found to be in accordance with the regional pathology of the diseases as reported in the clinical literature.