Researcher profile

M. Fouché

M. Fouché contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - Baseline
3works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Intensity interferometry of P Cygni in the H$α$ emission line: towards distance calibration of LBV supergiant stars

We present intensity interferometry of the luminous blue variable P Cyg in the light of its H$α$ emission performed with 1\,m-class telescopes. We compare the measured visibility points to synthesized interferometric data based on the CMFGEN physical modeling of a high-resolution spectrum of P Cyg recorded almost simultaneously with our interferometry data. Tuning the stellar parameters of P Cyg and its H$α$ linear diameter we estimate the distance of P Cyg as $1.56\pm0.25$~kpc, which is compatible within $1σ$ with $1.36\pm0.24$~kpc reported by the Gaia DR2 catalogue of parallaxes recently published. Both values are significantly smaller than the canonic value of $1.80\pm0.10$~kpc usually adopted in literature. Our method used to calibrate the distance of P Cyg can apply to very massive and luminous stars both in our galaxy and neighbour galaxies and can improve the so-called Wind-Momentum Luminosity relation that potentially applies to calibrate cosmological candles in the local Universe.

preprint2013arXiv

Vacuum magnetic linear birefringence using pulsed fields: the BMV experiment

We present the current status of the BMV experiment. Our apparatus is based on an up-to-date resonant optical cavity coupled to a transverse magnetic field. We detail our data acquisition and analysis procedure which takes into account the symmetry properties of the raw data with respect to the orientation of the magnetic field and the sign of the cavity birefringence. The measurement result of the vacuum magnetic linear birefringence k_\mathrm{CM}$ presented in this paper was obtained with about 200 magnetic pulses and a maximum field of 6.5\,T, giving a noise floor of about $8 \times 10^{-21}$\,T$^{-2}$ at $3σ$ confidence level.

preprint2010arXiv

Inverse Cotton-Mouton effect of the Vacuum and of atomic systems

In this letter we calculate the Inverse Cotton-Mouton Effect (ICME) for the vacuum following the predictions of Quantum ElectroDynamics. We compare the value of this effect for the vacuum with the one expected for atomic systems. We finally show that ICME could be measured for the first time for noble gases using state-of-the-art laser systems and for the quantum vacuum with near-future laser facilities like ELI and HiPER, providing in particular a test of the nonlinear behaviour of quantum vacuum at intensities below the Schwinger limit of 4.5x10^33 W/m^2.