Researcher profile

M. Da Rocha Rolo

M. Da Rocha Rolo contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2024arXiv

First results on monolithic CMOS detector with internal gain

In this paper we report on a set of characterisations carried out on the first monolithic LGAD prototype integrated in a customised 110 nm CMOS process having a depleted active volume thickness of 48 $μ$m. This prototype is formed by a pixel array where each pixel has a total size of 100 $μ$m $\times$ 250 $μ$m and includes a high-speed front-end amplifier. After describing the sensor and the electronics architecture, both laboratory and in-beam measurements are reported and described. Optical characterisations performed with an IR pulsed laser setup have shown a sensor internal gain of about 2.5. With the same experimental setup, the electronic jitter was found to be between 50 ps and 150 ps, depending on the signal amplitude. Moreover, the analysis of a test beam performed at the Proton Synchrotron (PS) T10 facility of CERN with 10 GeV/c protons and pions indicated that the overall detector time resolution is in the range of 234 ps to 244 ps. Further TCAD investigations, based on the doping profile extracted from $C(V)$ measurements, confirmed the multiplication gain measured on the test devices. Finally, TCAD simulations were used to tune the future doping concentration of the gain layer implant, targeting sensors with a higher avalanche gain. This adjustment is expected to enhance the timing performance of the sensors of the future productions, in order to cope with the high event rate expected in most of the near future high-energy and high-luminosity physics experiments, where the time resolution will be essential to disentangle overlapping events and it will also be crucial for Particle IDentification (PID).

preprint2020arXiv

Time performance of a triple-GEM detector at high rate

Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in regions of intense radiation, i.e. around the interaction point of collider machines. Among these, Micro Pattern Gaseous Detectors (MPGD) are the latest frontier and allow to overcome many limitations of the pre-existing detectors, such as the radiation tolerance and the rate capability. The gas Electron Multiplier (GEM) is a MPGD that exploits an intense electric field in a reduced amplification region in order to prevent discharges. Several amplification stages, like in a triple-GEM, allow to increase the detector gain and to reduce the discharge probability. Reconstruction techniques such as charge centroid (CC) and micro-Time Projection Chamber ($\upmu$TPC) are used to perform the position measurement. From literature triple-GEMs show a stable behaviour up to $10^8\,$Hz/cm$^2$. A testbeam with four planar triple-GEMs has been performed at the Mainz Microtron (MAMI) facility and their performance was evaluated in different beam conditions. In this article a focus on the time performance for the $\upmu$TPC clusterization is given and a new measurement of the triple-GEM limits at high rate will be presented.

preprint2019arXiv

A fast and parametric digitization for triple-GEM detectors

Triple-GEM detectors are a well known technology in high energy physics. In order to have a complete understanding of their behavior, in parallel with on beam testing, a Monte Carlo code has to be developed to simulate their response to the passage of particles. The software must take into account all the physical processes involved from the primary ionization up to the signal formation, e.g. the avalanche multiplication and the effect of the diffusion on the electrons. In the case of gas detectors, existing software such as Garfield already perform a very detailed simulation but are CPU time consuming. A description of a reliable but faster simulation is presented here: it uses a parametric description of the variables of interest obtained by suitable preliminary Garfield simulations and tuned to the test beam data. It can reproduce the real values of the charge measured by the strip, needed to reconstruct the position with the Charge Centroid method. In addition, particular attention was put to the simulation of the timing information, which permits to apply also the micro-Time Projection Chamber position reconstruction, for the first time on a triple-GEM. A comparison between simulation and experimental values of some sentinel variables in different conditions of magnetic field, high voltage settings and incident angle will be shown.

preprint2019arXiv

GRAAL: Gem Reconstruction And Analysis Library

MPGD are the new frontier in gas trackers. Among this kind of devices, theGEM chambers are widely used. The experimental signals acquired with the detector mustobviously be reconstructed and analysed. In this contribution, a new offline software to performreconstruction, alignment and analysis on the data collected with APV-25 and TIGER ASICswill be presented. GRAAL (Gem Reconstruction And Analysis Library) is able to measurethe performance of a MPGD detector with a strip segmented anode (presently). The code isdivided in three parts: reconstruction, where the hits are digitized and clusterized; tracking,where a procedure fits the points from the tracking system and uses that information to align thechamber with rotations and shifts; analysis, where the performance is evaluated (e.g. efficiency,spatial resolution,etc.). The user must set the geometry of the setup and then the programreturns automatically the analysis results, taking care of different conditions of gas mixture,electric field, magnetic field, geometries, strip orientation, dead strip, misalignment and manyothers.