Source author record

M. Brodeur

M. Brodeur appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

18works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

18 published item(s)

preprint2026arXiv

Precise Mass Measurement of the $^{149}$La-$^{149}$Ce-$^{149}$Pr isobaric chain

Penning trap mass measurements of $^{149}$La, $^{149}$Ce, and $^{149}$Pr were performed with the Canadian Penning Trap (CPT) at the CARIBU facility of Argonne National Laboratory using the phase-imaging ion-cyclotron-resonance technique. The resulting mass excess of $^{149}$La differs by 221 keV from a recent JYFLTRAP measurement, resulting in a significant change in the profile of the two-neutron separation energy for that isotopic chain. The mass excesses of $^{149}$Ce and $^{149}$Pr are determined with an eight-fold improvement in precision compared to previous time-of-flight ion-cyclotron-resonance measurements; the $^{149}$Ce value is consistent with AME2020, while the $^{149}$Pr mass excess is lower by 17.5 keV. The mass excesses of $^{149}$La and $^{149}$Pr reported in this work have been confirmed recently by a measurement with a multi-reflection time-of-flight mass spectrometer coupled to a $β$-time of flight detector at RIKEN, providing further validation of the present results.

preprint2022arXiv

Improved Limit on Tensor Currents in the Weak Interaction from $^8$Li $β$ Decay

The electroweak interaction in the Standard Model (SM) is described by a pure vector-axial-vector structure, though any Lorentz-invariant component could contribute. In this work, we present the most precise measurement of tensor currents in the low-energy regime by examining the $β$-$\barν$ correlation of trapped $^{8}$Li ions with the Beta-decay Paul Trap. We find $a_{βν} = -0.3325 \pm 0.0013_{stat} \pm 0.0019_{syst}$ at $1σ$ for the case of coupling to right-handed neutrinos $(C_T=-C_T')$, which is consistent with the SM prediction.

preprint2020arXiv

First Penning trap mass measurement of $^{36}$Ca

Isobaric quintets provide the best test of the isobaric multiplet mass equation (IMME) and can uniquely identify higher order corrections suggestive of isospin symmetry breaking effects in the nuclear Hamiltonian. The Generalized IMME (GIMME) is a novel microscopic interaction theory that predicts an extension to the quadratic form of the IMME. Only the $A=20, 32$ $T=2$ quintets have the exotic $T_z = -2$ member ground state mass determined to high-precision by Penning trap mass spectrometry. In this work, we establish $A=36$ as the third high-precision $T=2$ isobaric quintet with the $T_z = -2$ member ground state mass measured by Penning trap mass spectrometry and provide the first test of the predictive power of the GIMME. A radioactive beam of neutron-deficient $^{36}$Ca was produced by projectile fragmentation at the National Superconducting Cyclotron Laboratory. The beam was thermalized and the mass of $^{36}$Ca$^+$ and $^{36}$Ca$^{2+}$ measured by the Time of Flight - Ion Cyclotron Resonance method in the LEBIT 9.4 T Penning trap. We measure the mass excess of $^{36}$Ca to be ME$ = -6483.6(56)$ keV, an improvement in precision by a factor of 6 over the literature value. The new datum is considered together with evaluated nuclear data on the $A=36$, $T=2$ quintet. We find agreement with the quadratic form of the IMME given by isospin symmetry, but only coarse qualitative agreement with predictions of the GIMME. A total of three isobaric quintets have their most exotic members measured by Penning trap mass spectrometry. The GIMME predictions in the $T = 2$ quintet appear to break down for $A = 32$ and greater.

preprint2020arXiv

High precision mass measurements of the isomeric and ground states of $^{44}$V: improving constraints on the IMME parameters of the A=44, $\text{0}^{\text{+}}$ quintet

The Isobaric Multiplet Mass Equation (IMME) has been successful at predicting the masses of isobaric analogue states in the same multiplet, while its coefficients are known to follow trends as functions of mass number. The Atomic Mass Evaluation 2016 [Chin. Phys. C 41, 030003 (2017)] $^{44}$V mass value results in an negative $c$ coefficient for the IMME quadratic term. The $b$ and $c$ coefficients can provide constraints for construction of the isospin-nonconserving (INC) Hamiltonians for the $pf$ shell. The excitation energy of the $0^+, T=2$ level in $^{44}$V is currently unknown and can be used to constrain the $^{44}$Cr mass. The aim of the experiment was to perform high-precision mass measurements to resolve the difference between $^{44}$V isomeric and ground states, to test the IMME, and to provide ingredients for identifying the $0^+$, $T=2$ state in $^{44}$V. High-precision Penning trap mass spectrometry was performed at LEBIT, to measure the cyclotron frequency ratios of [$^{44g,m}$VO]$^+$ versus [$^{32}$SCO]$^+$, a reference mass, to extract both the isomeric and ground state masses of $^{44}$V. The mass excess of the ground and isomeric states in $^{44}$V were measured to be $-23\ 804.9(80)$ keV/$\text{c}^2$ and $-23\ 537.0(55)$ keV/$\text{c}^2$. This yielded a new proton separation energy of $S_p$ = 1\ 773(10) keV. The new mass values of $^{44}$V have been used to deduce the IMME $b$ and $c$ coefficients of the lowest $2^+$ and $6^+$ triplets in $A=44$. The $2^+$ $c$ coefficient is verified with the IMME trend and agrees with the shell-model predictions using charge-dependent Hamiltonians. The mirror energy differences were determined between $^{44}$V and $^{44}$Sc, in line with isospin-symmetry. The new value of the proton separation energy determined will be important for the determination of the $0^+$, $T=2$ state in $^{44}$V and for prediction of the mass of $^{44}$Cr.

preprint2019arXiv

Exploring the mass surface near the rare-earth abundance peak via precision mass measurements at JYFLTRAP

The JYFLTRAP double Penning trap at the Ion Guide Isotope Separator On-Line (IGISOL) facility has been used to measure the atomic masses of 13 neutron-rich rare-earth isotopes. Eight of the nuclides, $^{161}$Pm, $^{163}$Sm, $^{164,165}$Eu, $^{167}$Gd, and $^{165,167,168}$Tb, were measured for the first time. The systematics of the mass surface has been studied via one- and two-neutron separation energies as well as neutron pairing-gap and shell-gap energies. The proton-neutron pairing strength has also been investigated. The impact of the new mass values on the astrophysical rapid neutron capture process has been studied. The calculated abundance distribution results in a better agreement with the solar abundance pattern near the top of the rare-earth abundance peak at around $A\approx165$.

preprint2016arXiv

Status of the NSCL Cyclotron Gas Stopper

A gas-filled reverse cyclotron for the thermalisation of energetic beams is under construction at NSCL/MSU. Rare isotopes produced via projectile fragmentation after in-flight separation will be injected into the device and converted into low-energy beams through buffer gas interactions as they spiral towards the centre of the device. The extracted thermal beams will be used for low energy experiments such as precision mass measurements with traps or laser spectroscopy, and further transport for reacceleration. Detailed calculations have been performed to optimize the magnetic field design as well as the transport and stopping of ions inside the gas. An RF carpet will be used to transport the thermal ions to the axial extraction point. The calculations indicate that the cyclotron gas stopper will be much more efficient for the thermalisation of light and medium mass ions compared to linear gas cells. In this contribution we will discuss simulations of the overall performance and acceptance of machine, the beam matching calculations to the fragment separator emittance, and the construction status.

preprint2015arXiv

First direct determination of the superallowed $β$-decay $Q_{EC}$-value for $^{14}$O

We report the first direct measurement of the $^{14}\text{O}$ superallowed Fermi $β$-decay $Q_{EC}$-value, the last of the so-called "traditional nine" superallowed Fermi $β$-decays to be measured with Penning trap mass spectrometry. $^{14}$O, along with the other low-$Z$ superallowed $β$-emitter, $^{10}$C, is crucial for setting limits on the existence of possible scalar currents. The new ground state $Q_{EC}$ value, 5144.364(25) keV, when combined with the energy of the $0^+$ daughter state, $E_x(0^+)=2312.798(11)$~keV [Nucl. Phys. A {\bf{523}}, 1 (1991)], provides a new determination of the superallowed $β$-decay $Q_{EC}$ value, $Q_{EC}(\text{sa}) = 2831.566(28)$ keV, with an order of magnitude improvement in precision, and a similar improvement to the calculated statistical rate function $f$. This is used to calculate an improved $\mathcal{F}t$-value of 3073.8(2.8) s.

preprint2015arXiv

Mass measurements of neutron-rich Rb and Sr isotopes

We report on the mass measurements of several neutron-rich $\mathrm{Rb}$ and $\mathrm{Sr}$ isotopes in the $A \approx 100$ region with the TITAN Penning-trap mass spectrometer. Using highly charged ions in the charge state $q=10+$, the masses of $^{98,99}\mathrm{Rb}$ and $^{98-100}\mathrm{Sr}$ have been determined with a precision of $6 - 12\ \mathrm{keV}$, making their uncertainty negligible for r-process nucleosynthesis network calculations. The mass of $^{101}\mathrm{Sr}$ has been determined directly for the first time with a precision eight times higher than the previous indirect measurement and a deviation of $3σ$ when compared to the Atomic Mass Evaluation. We also confirm the mass of $^{100}\mathrm{Rb}$ from a previous measurement. Furthermore, our data indicates the existance of a low-lying isomer with $80\ \mathrm{keV}$ excitation energy in $^{98}\mathrm{Rb}$. We show that our updated mass values lead to minor changes in the r-process by calculating fractional abundances in the $A\approx 100$ region of the nuclear chart.

preprint2014arXiv

Breakdown of the Isobaric Multiplet Mass Equation for the A = 20 and 21 Multiplets

Using the Penning trap mass spectrometer TITAN, we performed the first direct mass measurements of 20,21Mg, isotopes that are the most proton-rich members of the A = 20 and A = 21 isospin multiplets. These measurements were possible through the use of a unique ion-guide laser ion source, a development that suppressed isobaric contamination by six orders of magnitude. Compared to the latest atomic mass evaluation, we find that the mass of 21Mg is in good agreement but that the mass of 20Mg deviates by 3σ. These measurements reduce the uncertainties in the masses of 20,21Mg by 15 and 22 times, respectively, resulting in a significant departure from the expected behavior of the isobaric multiplet mass equation in both the A = 20 and A = 21 multiplets. This presents a challenge to shell model calculations using either the isospin non-conserving USDA/B Hamiltonians or isospin non-conserving interactions based on chiral two- and three-nucleon forces.

preprint2013arXiv

Trapped-ion decay spectroscopy towards the determination of ground-state components of double-beta decay matrix elements

A new technique has been developed at TRIUMF's TITAN facility to perform in-trap decay spectroscopy. The aim of this technique is to eventually measure weak electron capture branching ratios (ECBRs) and by this to consequently determine GT matrix elements of $ββ$ decaying nuclei. These branching ratios provide important input to the theoretical description of these decays. The feasibility and power of the technique is demonstrated by measuring the ECBR of $^{124}$Cs.

preprint2012arXiv

Elucidation of the anomalous A = 9 isospin quartet behaviour

Recent high-precision mass measurements of $^{9}$Li and $^{9}$Be, performed with the TITAN Penning trap at the TRIUMF ISAC facility, are analyzed in light of state-of-the-art shell model calculations. We find an explanation for the anomalous Isobaric Mass Multiplet Equation (IMME) behaviour for the two $A$ = 9 quartets. The presence of a cubic $d$ = 6.3(17) keV term for the $J^π$ = 3/2$^{-}$ quartet and the vanishing cubic term for the excited $J^π$ = 1/2$^{-}$ multiplet depend upon the presence of a nearby $T$ = 1/2 state in $^{9}$B and $^{9}$Be that induces isospin mixing. This is contrary to previous hypotheses involving purely Coulomb and charge-dependent effects. $T$ = 1/2 states have been observed near the calculated energy, above the $T$ = 3/2 state. However an experimental confirmation of their $J^π$ is needed.

preprint2012arXiv

Highly charged ions in Penning traps, a new tool for resolving low lying isomeric states

The use of highly charged ions increases the precision and resolving power, in particular for short-lived species produced at on-line radio-isotope beam facilities, achievable with Penning trap mass spectrometers. This increase in resolving power provides a new and unique access to resolving low-lying long-lived ($T_{1/2} > 50$ ms) nuclear isomers. Recently, the $111.19(22)$ keV (determined from $γ$-ray spectroscopy) isomeric state in $^{78}$Rb has been resolved from the ground state, in a charge state of $q=8+$ with the TITAN Penning trap at the TRIUMF-ISAC facility. The excitation energy of the isomer was measured to be $108.7(6.4)$ keV above the ground state. The extracted masses for both the ground and isomeric states, and their difference, agree with the AME2003 and Nuclear Data Sheet values. This proof of principle measurement demonstrates the feasibility of using Penning trap mass spectrometers coupled to charge breeders to study nuclear isomers and opens a new route for isomer searches.

preprint2012arXiv

Penning-Trap Mass Measurements of the Neutron-Rich K and Ca Isotopes: Resurgence of the N = 28 Shell Strength

We present Penning-trap mass measurements of neutron-rich 44,47-50K and 49,50Ca isotopes carried out at the TITAN facility at TRIUMF-ISAC. The 44K mass measurement was performed with a charge-bred 4+ ion utilizing the TITAN EBIT, and agrees with the literature. The mass excesses obtained for 47K and 49,50Ca are more precise and agree with the values published in the 2003 Atomic Mass Evaluation (AME'03). The 48,49,50K mass excesses are more precise than the AME'03 values by more than one order of magnitude. For 48,49K, we find deviations by 7 sigma and 10 sigma, respectively. The new 49K mass excess lowers significantly the two-neutron separation energy at the neutron number N=30 compared with the separation energy calculated from the AME'03 mass-excess values, and thus, increases the N=28 neutron-shell gap energy at Z=19 by approximately 1 MeV.

preprint2012arXiv

TITAN's Digital RFQ Ion Beam Cooler and Buncher, Operation and Performance

We present a description of the Radio Frequency Quadrupole (RFQ) ion trap built as part of the TITAN facility. It consists of a gas-filled, segmented, linear Paul trap and is the first stage of the TITAN setup with the purpose of cooling and bunching radioactive ion beams delivered from ISAC-TRIUMF. This is the first such device to be driven digitally, i.e., using a high voltage ($V_{pp} = \rm{400 \, V}$), wide bandwidth ($0.2 < f < 1.2 \, \rm{MHz}$) square-wave as compared to the typical sinusoidal wave form. Results from the commissioning of the device as well as systematic studies with stable and radioactive ions are presented including efficiency measurements with stable $^{133}$Cs and radioactive $^{124, 126}$Cs. A novel and unique mode of operation of this device is also demonstrated where the cooled ion bunches are extracted in reverse mode, i.e., in the same direction as previously injected.

preprint2011arXiv

First direct mass-measurement of the two-neutron halo nucleus 6He and improved mass for the four-neutron halo 8He

The first direct mass-measurement of $^{6}$He has been performed with the TITAN Penning trap mass spectrometer at the ISAC facility. In addition, the mass of $^{8}$He was determined with improved precision over our previous measurement. The obtained masses are $m$($^{6}$He) = 6.018 885 883(57) u and $m$($^{8}$He) = 8.033 934 44(11) u. The $^{6}$He value shows a deviation from the literature of 4$σ$. With these new mass values and the previously measured atomic isotope shifts we obtain charge radii of 2.060(8) fm and 1.959(16) fm for $^{6}$He and $^{8}$He respectively. We present a detailed comparison to nuclear theory for $^6$He, including new hyperspherical harmonics results. A correlation plot of the point-proton radius with the two-neutron separation energy demonstrates clearly the importance of three-nucleon forces.

preprint2011arXiv

First Use of High Charge States for Mass Measurements of Short-lived Nuclides in a Penning Trap

Penning trap mass measurements of short-lived nuclides have been performed for the first time with highly-charged ions (HCI), using the TITAN facility at TRIUMF. Compared to singly-charged ions, this provides an improvement in experimental precision that scales with the charge state q. Neutron-deficient Rb-isotopes have been charge bred in an electron beam ion trap to q = 8 - 12+ prior to injection into the Penning trap. In combination with the Ramsey excitation scheme, this unique setup creating low energy, highly-charged ions at a radioactive beam facility opens the door to unrivalled precision with gains of 1-2 orders of magnitude. The method is particularly suited for short-lived nuclides such as the superallowed β emitter 74Rb (T1/2 = 65 ms). The determination of its atomic mass and an improved QEC-value are presented.

preprint2011arXiv

Verifying the accuracy of the TITAN Penning-trap mass spectrometer

TITAN (TRIUMF's Ion Traps for Atomic and Nuclear science) is an online facility designed to carry out high-precision mass measurements on singly and highly charged radioactive ions. The TITAN Penning trap has been built and optimized in order to perform such measurements with an accuracy in the sub ppb-range. A detailed characterization of the TITAN Penning trap is presented and a new compensation method is derived and demonstrated, verifying the performance in the range of sub-ppb.