Source author record

Luis Peralta

Luis Peralta appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Comparison of Radon Mass Exhalation Rate Measurements from Building Materials by two Different Methods

The aim of this study is to measure the radon mass exhalation rate from common granite building materials used in the East and Northeast part of Portugal. Twelve cubic shaped samples were measured. Nine of them without any coating and three coated with different materials (varnish,hydrorepellent and liquid silicone). The radon measurements were performed with two different techniques: one using passive detectors and other using an active detector. For the passive method CR-39 solid state nuclear track detectors were used. The active method used the RAD7 DURRIDGE detector. Radon mass exhalation rates obtained from both methods present relatively low values in the 11 to 45 mBq/kg/h range for the analyzed samples. Concerning the coated samples, the measured values are on average four times lower than the ones without coating. Overall, the measured values for both methods present a good agreement.

preprint2020arXiv

Development of a low-cost monitor for radon detection in air

An active device for radon detection in the air was developed. The monitor operates in pulse counting mode for real-time continuous measurements. The presented prototype has a relatively simple design made of low-price and easy to acquire components which made it possible to develop an inexpensive device. The device used as a sensor, the SLCD-61N5 Si-PIN planar photodiode, which has an area of 9.67x9.67 mm2, is sensitive to alpha particles. An Arduino Uno microcontroller was used as a data acquisition system. Signals were observed when placing an 241Am or 226Ra source near the sensor. The sensor's sensitivity has small bias dependency and the device can operate even at modest voltage. As a result of a one-month test in a radon-rich atmosphere, a positive high correlation (Pearson's r equal to 0.977) was obtained between our prototype and a Geiger-Muller detector.

preprint2019arXiv

Radon Concentration Potential in Bibala Municipality Water: Consequences for Public Consumption

The primary motivation for this work is the evaluation of the radon concentration in portable water for human consumption in Bibala, a municipality in Angola, where granitic rocks are common, and contain a high concentration of uranium that can be mobilized in underground water. Radon is the largest contributor of radioactive pollution in underground water.Its concentration in water, represents a public health risk due to the fact that the gas can easily escape into the air, adding to the total indoor concentration of radon.On the other hand, ingestion of water with a high radon concentration represents an additional risk to the stomach. Measurements of radon concentration, in Bibala municipality's water, were performed on 16 samples obtained from wells of various depths and analyzed with DURRIDGEs' RAD7 equipment. Measured concentrations are in the range from 39.5 to 202 Bq/L , with 2 of the recovered samples presenting values over 100 Bq/L.

preprint2011arXiv

A Scintillating Fiber Dosimeter for Radiology and Brachytherapy with photodiode readout

Purpose: For more than a decade that plastic optical fiber based dosimeters have been developed for medical applications. The feasibility of dosimeters using optical fibers that are almost Cherenkov light free has been demonstrated in some prototypes, particularly suitable for photon high-energy beams. In the energy range up to a few hundred keV, where the production of Cherenkov light by secondary electrons is negligible or small, the largest source of background are the fluorescence mechanisms. Methods: In recent years our group has developed an optical fiber dosimeter with photodiode readout named DosFib, which has small energy dependence in the range below 100 keV relevant for radiology. Photodiodes are robust photodetectors, presenting good stability over time and enough sensitivity to allow the use of an electrometer as a measuring device without extra electronics. Results: In-vitro tests using a High Dose Rate 192Ir source have demonstrated its suitability for brachytherapy applications using this important radioactive source. Attenuation curves have been obtained in water with the DosFib dosimeter and an ionization chamber and the depth dose profiles shown to be identical. Conclusions: This new dosimeter can thus be calibrated and used in clinical measurements with good competitive advantages over other dosimeters.