Source author record

Luigi Cosentino

Luigi Cosentino appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
3close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2012arXiv

Assessment of a high-resolution candidate detector for prostate time-of-flight positron emission tomography

We report on the measurements performed using a 22Na source on a detector element for an MRI-compatible TOF-PET endorectal prostate probe, with Depth-Of-Interaction sensitivity. It is made from a LYSO scintillator crystal, wrapped with Lumirror, readout at both ends by means of Silicon Photomultipliers. With a detailed description of the data analysis procedure we show that our results point to a 400 ps coincidence resolving time and, at the same time, to a Depth-Of-Interaction resolution of 1 mm. These appealing features, along with the tiny 1.5 mm x 1.5 mm x 10 mm crystal size, are quite promising in view of the realization of a prototype probe.

preprint2012arXiv

High-resolution Time-Of-Flight PET with Depth-Of-Interaction becomes feasible: a proof of principle

In this paper we prove that the choice of a suitable treatment of the scintillator surfaces, along with suitable photodetectors electronics and specific algorithms for raw data analysis, allow to achieve an optimal tradeoff between energy, time and DOI resolution, thus strongly supporting the feasibility of a prostate TOF- PET probe, MRI compatible, with the required features and performance. In numbers this means a detector element of 1.5mm x 1.5mm x 10mm, achieving at the same time energy resolution around 11.5%, time-of- flight resolution around 150 ps and DOI resolution even below 1 mm. We stress that such a time resolution allows to increase significantly the Noise Equivalent Counting Rate, and consequently improve the image quality and the lesion detection capability. These individual values correspond to the best obtained so far by other groups, but we got all of them simultaneously. In our opinion this proof of principle paves the way to the feasibility of a TOF-PET MRI compatible probe with unprecedented features and performance, not only innovative for prostate radiotracer imaging but possibly also for other organs.